1.
Article | IMSEAR | ID: sea-219048

ABSTRACT

Aim: To study the cost-effectiveness of clinical screen with ultrasonography (USG) of hip for diagnosing developmental dysplasia of the hip (DDH) in new borns. Methodology: Prospective study was conducted in DVVPF's Medical College and Hospital, Ahmednagar over a period of two years. Term new borns had (i) target scan at 6 weeks—family history of DDH or breech presentation—and (ii) early scan—abnormal clinical screen. Results: In all, 58 babies had USG scan. Five early scans (Graf's classification; three Type IIA, one Type IIC and one Type IIIB] and 15 target scans (Type IIA) were reported abnormal. All Type IIADDH had subsequent 12 weeks' scans normal. Babies with Type IIIB and IIC had hip reduction surgery at 6 and 16 months of age, respectively. At cost Rs. 200 INR/- scan, total Rs. 1,47,200/- INR was incurred against two possible hip replacements prevented. Conclusion: Universal clinical screen with USG of hip can aid in early diagnosis of DDH in newborns. Large population-based studies from developing countries need to look in its cost-effectiveness.

2.
Article | IMSEAR | ID: sea-219093

ABSTRACT

For inter trochanteric fracture Proximal Femoral Nail (PFN) is a better choice of implant biomechanically. But in communicated inter trochanteric fractures it is associated with screw breakage, cut out through femoral head, ”Z” & reverse “Z” effect and lateral migration of screws. The purpose of this study is to evaluate the results of PFN in terms of post-operative complication and failure rates in unstable trochanteric fracture with addition of 1 or 2 tension band wires. Material & Method:We did study of 21 unstable trochanteric fractures from January 2016 to November .2020. 14 patients were males & 7 patients were females. Age group between 25 to 80 was included in this group. There were 15 A0 A2 (2.2, 2.3) and 6 were A0 A3 (3.1, 3.2, 3.3). All fractures were ?xed with 25cm, 0135PFN mainly 11 mm, 12mm in diameter with addition of one or two 16 gauge tension band wire, strengthening lateral trochanteric wall and holding either communiated fragments or lesser trochanteric fracture. Results:The fracture was united in all cases with mean period of 16 weeks. Two patients developed complication of TBW (Tension Band Wire) breakage; one developed lateral migration of screws. Patients were followed till bone was united. At the end of follow up hip function were 30 (out of 40) in 80% patients by using Salvati and Wilson hip score. Conclusion: The stabilization of lateral trochanteric wall fracture and communiated fragments of inter trochanteric fractures, additional one or two TBW increases the stability of construct enhancing bony union & better results.

SELECTION OF CITATIONS
SEARCH DETAIL