Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Central South University(Medical Sciences) ; (12): 776-782, 2017.
Article in Chinese | WPRIM | ID: wpr-606844

ABSTRACT

Objective:To observe the sensitivity of transcription mediated amplification (TMA),and to compare its performance with real-time reverse transcription polymerase chain reaction (real-time RT-PCR) in detecting human immunodeficiency virus RNA (HIV RNA).Methods:TMA system was established with TaqMan probes,specific primers,moloney murine leukemia virus (MMLV) reverse transcriptase,T7 RNA polymerase,and reaction substrates.The sensitivity of TMA was evaluated by amplifying a group of 10-fold diluted HIV RNA standards which were transcribed in vitro.A total of 60 plasma of HIV infected patients were measured by TMA and Cobas Amplicor HIV-1 Monitor test to observe the positive rate.The correlation and concordance of the above two technologies were investigated by linear regression and BlandAltman analysis.Results:TMA system was established successfully and HIV RNA transcribed standards at concentration of equal or more than 10 copies/mL could be detected by TMA technology.Among 60 samples of plasma from HIV infected patients,46 were positively detected and 12 were negatively amplified by both TMA and Cobas reagents;2 samples were positively tested by Cobas reagent but negatively tested by TMA system.The concordance rate of the two methods was 97.1% and the difference of positive detection rate between the two methods was not statistically significant (P>0.05).Linear regression was used for 46 samples which were positively detected by both TMA and Cobas reagents and showed an excellent correlation between the two reagents (r=0.997,P<0.001).Bland-Altma analysis revealed that the mean different value ofHIV RNA levels for denary logarithm was 0.02.Forty-four samples were included in 95% of credibility interval of concordance.Conclusion:TMA system has the potential of high sensitivity.TMA and real-time RT-PCR keep an excellent correlation and consistency in detecting HIV RNA.

2.
Journal of Central South University(Medical Sciences) ; (12): 664-672, 2014.
Article in Chinese | WPRIM | ID: wpr-468218

ABSTRACT

Objective:To observe the stability and sensitivity of transcription mediated ampliifcation (TMA) system, and to compare it with real-time reverse transcription polymerase chain reaction (RT-PCR) in amplifying serum HCV RNA in HCV infected patients. Methods: TMA system was established by moloney murine leukemia virus (MMLV) reverse transcriptase, T7 RNA polymerase and 2 speciifc primers ifrstly,and then its stability and repeatability were compared at different storage temperatures by the correlation change of HCV RNA amplification curve. The sensitivity difference between TMA and RT-PCR was evaluated by amplifying a group of 10-fold diluted HCV RNA samples which were transcribed in vitro. A total of 101 serums of chronic HCV infected patients were measured by TMA system and RT-PCR to observe the positive rate and their correlation. Linear correlation and linear regression were used to observe the correlation of the two methods. Results:TMA system was successfully established. TMA system was not stable when stored at 20℃ (placed for 24 hours only), but it was stable for 6 days when stored at 4℃ or within 6 months when stored at-20 ℃. Compared with RT-PCR whose reagent was made by Hunan Sansure Biotechology Corporation, TMA system showed 20 positive samples and 11 negative samples in a total of 31 samples. So was the RT-PCR kit of the Sansure Biotechology Corporation, and the concordance rate of the two methods was 100%. Advanced quantitative study of the 20 positive samples found that the two methods had good correlation and consistency (r=0.91,P0.05). Advanced quantitative study of 29 positive samples found that the two methods had good correlation and consistency (r=0.96,P<0.01). Conclusion:The stability and repeatability of TMA system are good within 6 months when stored at-20 ℃ storage temperature. Both TMA and RT-PCR HCV RNA can detect serum HCV RNA well, and the two methods have good correlation and consistency.

SELECTION OF CITATIONS
SEARCH DETAIL