1.
Chinese Journal of Nuclear Medicine and Molecular Imaging ; (6): 658-662, 2020.
Article in Chinese | WPRIM | ID: wpr-869208

ABSTRACT

Objective:To investigate the application value of renal depth correction by the integrated CT in glomerular filtration rate (GFR) determination by 99Tc m-diethylene triamine pentoacetic acid (DTPA) renal dynamic imaging for patients with hydronephrosis. Methods:A total of 338 patients (191 males, 147 females, age (49.6±14.5) years) in Beijing Tsinghua Changgung Hospital from April 2016 to June 2019 with different degrees of hydronephrosis were respectively analyzed. Patients were divided into groups of normal-mild, normal-moderate, normal-heavy, mild-mild, mild-moderate, mild-heavy, moderate-moderate, moderate-heavy and heavy-heavy according to the degree of bilateral hydronephrosis. The renal depth was measured by the integrated CT method and the routine method, and the absolute value of bilateral renal depth difference in normal-mild, normal-moderate and normal-heavy groups was calculated by the 2 methods. Based on the renal depth measured by the 2 methods, the single renal GFR was measured by 99Tc m-DTPA dynamic renal imaging Gates method and compared between the 2 methods. Total GFR measured by the 2 methods were compared with estimated GFR (eGFR). One-way analysis of variance analysis, paired t test, and Pearson correlation analysis were used. Results:For the integrated CT measurements, the absolute value of bilateral renal depth difference in normal-mild, normal-moderate and normal-heavy groups were significantly different ((0.39±0.24), (1.16±0.65) and (1.00±0.90) cm; F=15.241, P<0.05). The renal depth and the single renal GFR measured by the integrated CT method were higher than those measured by the routine method ( t values: 16.06-19.78, 14.27-17.23, all P<0.05) in the kidneys with normal, mild, moderate and heavy hydronephrosis. There were significant differences between the total GFR measured by the routine method and eGFR in all groups ( t values: from -8.178 to 5.879, all P<0.05); however, in the integrated CT method, except that the total GFRs in moderate-heavy group and heavy-heavy group were overestimated ( t values: 3.035 and 11.247, both P<0.05), there were no significant differences between the total GFR ((111.57±17.37), (103.71±15.22), (79.79±12.62), (100.33±18.49), (100.28±15.43), (84.09±20.72) and (74.14±14.57) ml·min -1·1.73 m -2) and eGFR ((109.16±12.81), (103.20±13.26), (78.60±14.12), (100.98±15.20), (99.89±14.05), (84.61±20.24) and (73.44±14.57) ml·min -1·1.73 m -2) in normal-mild, normal-moderate, normal-heavy, mild-mild, mild-moderate, mild-heavy and moderate-moderate groups ( t values: from -0.301 to 1.948, all P>0.05). The total GFR measured by the 2 methods were significantly correlated with eGFR in 338 patients with hydronephrosis ( r values: 0.888 and 0.928, both P<0.01). Conclusion:Compared with the routine method, except for the moderate-heavy group and heavy-heavy group, renal depth correction by the integrated CT may have greater clinical significance in GFR measurement by renal dynamic imaging for patients with hydronephrosis.

2.
Chinese Medical Equipment Journal ; (6): 32-35, 2017.
Article in Chinese | WPRIM | ID: wpr-618968

ABSTRACT

Objective To discuss the practicability of application of fault tree analysis in innovation to electrical system of SL-IE radiotherapy simulator.Methods The structure and principle of the electrical system were analyzed,the fault tree for the electrical system was built,and the qualitative analysis and quantitative analysis to the fault tree were made.The electrical system was innovated with effective redundant method,and the qualitative analysis and quantitative analysis were made after innovation.Theoretical analysis and the actual validation were made for the fault tree of electrical system after innovation.Finally,several notes were provided for the innovation to the similar medical equipments.Results The fault tree analysis method was applied to innovating the electrical system,and theoretical analysis indicated that the failure probability to total system reduced obviously.Actually,the actual effect after innovation also validated the correctness of the theoretical analysis.Conclusion Application of fault tree analysis in innovation to electrical system of SL-IE radiotherapy simulator is practical.But,the selection to the innovation event,the change to maintainence after innovation and the event to innovate carefully should be paid attention to.

3.
China Journal of Chinese Materia Medica ; (24): 1682-1685, 2011.
Article in Chinese | WPRIM | ID: wpr-354178

ABSTRACT

Chinese yew is a medicinal plant which has the largest planted area, better economic effects and ecological benefits in our country. People have insufficient appreciation of centuries-old historical document and abundant cultural connotation of Chinese yew, because Chinese yew had no name in ancient times and some expressions of western countries are still cited at present. Therefore, this paper did a great deal of analysis and reference works focusing on synonym and byname of ancient Chinese yew. Excavation and classification of historical documents of Chinese yew from ancient classics and bibliography had been done by studying 3 503 books, about billions of words been recorded in the Si Ku Quan Shu. These researches made up for simple and inadequate contents of many large tool books, like Chinese materia medica and traditional Chinese medicine, and so on. At the same time, in order to change the situation of no name, uncertain channel tropism, irregular functions of Chinese yew, its property and flavor, channel tropism, effects and functions had been summarized. History of the tumor treatment of Chinese yew had been traced back to the time of Tang Dynasty and this was almost 1 200 years earlier than western countries.


Subject(s)
Medicine, Chinese Traditional , Methods , Taxus
SELECTION OF CITATIONS
SEARCH DETAIL