Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Arq. bras. med. vet. zootec ; 61(4): 844-852, ago. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-524438

ABSTRACT

Avaliaram-se a biocompatibilidade, a osseointegração, a osseocondução e a biodegradação de compósitos de 50 por cento hidroxiapatita (HAP-91®) e 50 por cento poli-hidroxibutirato. O compósito foi implantado em defeitos ósseos em 12 coelhos (grupo experimental), sendo comparado a defeitos não preenchidos (grupo-controle, de igual número). Os parâmetros clínicos dor, claudicação, infecção, deiscência e edema foram avaliados nos primeiros oito dias após a cirurgia e aos 45 e 90 dias. Radiografias foram realizadas aos oito, 45 e 90 dias após a cirurgia em quatro animais por grupo que, em seguida, foram submetidos à eutanásia para coleta de amostras destinadas a análises histológica e histomorfométrica. Não ocorreram diferenças entre os grupos para todos os parâmetros clínicos. Radiografias demonstraram um compósito com radiopacidade semelhante à do osso vizinho e contato direto entre osso e compósito aos 45 e 90 dias. Diferença significativa foi observada entre a porcentagem dos tecidos ósseo e conjuntivo dentro do defeito nos dias oito, 45 e 90, assim como na interface aos 45 e 90 dias. Foram observadas projeções dos tecidos ósseo e conjuntivo no interior do compósito e sinais de biodegradação na ausência de infiltrado inflamatório. Pode-se concluir que o compósito é biocompatível, osseocondutor, biodegradável e se integra ao tecido ósseo.


The biocompatibility, osseointegration, osseoconductivity, and biodegradation of a 50-50 percent hydroxyapatite (HAP-91®)-polyhydroxybutyrate were evaluated. The composite was implanted in bone defects of 12 rabbits (experimental group), being compared to unfilled defects (control group, 12 animals). The clinical parameters of pain, lameness, infection, dehiscence, and edema were evaluated during the first eight days and on the 45th and 90th days after surgery. Radiographs were taken in four animals per group at 8, 45, and 90 days after surgery, when animals were euthanized to collect samples for histology and histomorphometry. Significant differences between groups for all clinical parameters were not observed. Radiographs showed a similar radiopacity of the composite and bone and their direct contact. More bone than connective tissue was found within the defect at 8, 45, and 90 days and at the interface on the 45th and 90th days. Projections of bone and connective tissue were seen inside the composite. Biodegradation signs became evident, with absence of inflammatory infiltrate. Data support that such composite is biocompatible, osseoconductive, biodegradable, and integrate to bone.

2.
AMB rev. Assoc. Med. Bras ; 27(3): 99-102, 1981.
Article in Portuguese | LILACS | ID: lil-3260

ABSTRACT

Os autores apresentam os resultados de um estudo experimental sobre a interposicao de retalhos de dura-mater humana em traqueia de caes. Foram utilizados 22 animais, divididos em tres series, de acordo com o tempo de evolucao do implante, que variou de 1 a 4 meses e meio. O comportamento do implante foi avaliado sob os parametros clinicos e anatomopatologicos. Nao foram observadas alteracoes clinicas em nenhum dos animais e, com relacao aos estudos anatomopatologicos, houve aparente integracao da dura-mater com a traqueia


Subject(s)
Dura Mater , Surgical Flaps , Trachea
SELECTION OF CITATIONS
SEARCH DETAIL