Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
J. bras. pneumol ; 33(2): 148-151, mar.-abr. 2007. graf, tab
Article in Portuguese | LILACS | ID: lil-459284

ABSTRACT

OBJETIVO: Determinar a eficácia do uso do volume expiratório forçado nos primeiros seis segundos (VEF6) como substituto da capacidade vital forçada (CVF) na triagem diagnóstica da doença pulmonar obstrutiva crônica (DPOC) através da comparação entre as medidas da relação VEF1/CVF e as medidas da relação VEF1/VEF6. MÉTODOS: No ano de 2003, durante o Dia Mundial da DPOC, realizamos uma campanha de triagem diagnóstica da DPOC. Os participantes da campanha respondiam ao questionário clínico do projeto Global Initiative for -Obstructive Lung Disease e aqueles que apresentavam pelo menos três respostas positivas submetiam-se a espirometria. RESULTADOS: Um total de 134 indivíduos respondeu positivamente a três questões e realizou espirometria. Destes, 59 foram excluídos: 45 por serem não fumantes e 14 pelo fato de seus exames não obedecerem aos critérios da American Thoracic Society para espirometria de qualidade. O número de resultados abaixo de 70 por cento foi similar para VEF1/CVF e para VEF1/VEF6. A sensibilidade de VEF1/VEF6 para o diagnóstico de obstrução de vias aéreas definida por VEF1/CVF abaixo de 70 por cento foi de 92 por cento e a especificidade foi de 99 por cento. O valor preditivo positivo foi de 100 por cento e o valor preditivo negativo foi de 98 por cento. O teste de correlação de Kendall mostrou r = 0,99 (p < 0,0001). O teste t para amostras pareadas mostrou correlação negativa: t = -5,93 (p < 0,0001). CONCLUSÃO: A relação VEF1/VEF6 se mostrou eficaz para uso na triagem diagnóstica da DPOC. Existe uma forte relação entre VEF1/CVF e VEF1/VEF6.


OBJECTIVE: To determine the efficacy of using forced expiratory volume in six seconds (FEV6) as a surrogate for forced vital capacity (FVC) in the diagnostic screening for chronic obstructive pulmonary disease (COPD) by comparing FEV1/FVC ratios with FEV1/FEV6 ratios. METHODS: In November of 2003, on World COPD Day, we conducted a campaign of diagnostic screening for COPD. The participants completed the clinical questionnaire of the Global Initiative for Obstructive Lung Disease, and those who responded affirmatively to at least three questions underwent spirometry. RESULTS: A total of 134 individuals responded to three questions affirmatively and underwent spirometry. Of those, 59 were excluded: 45 for being non-smokers and 14 due to the fact that their tests did not meet the American Thoracic Society criteria for satisfactory spirometry. The number of tests in which the FEV1/FEV6 ratio was below 70 percent was similar to that found for the FEV1/FVC ratio. The sensitivity of FEV1/FEV6 in diagnosing airway obstruction (defined as FEV1/FVC below 70 percent) was 92 percent, and its specificity was 99 percent. The positive predictive value was 100 percent, and the negative predictive value was 98 percent. The Kendall correlation test revealed r = 0.99 (p < 0.0001). The t-test for paired samples revealed a negative correlation: t = -5.93 (p < 0.0001). CONCLUSION: The FEV1/FEV6 proved efficient for use in the diagnostic screening for COPD. There is a strong correlation between FEV1/FVC and FEV1/FEV6.


Subject(s)
Female , Humans , Male , Middle Aged , Forced Expiratory Volume/physiology , Pulmonary Disease, Chronic Obstructive/diagnosis , Vital Capacity/physiology , Mass Screening , Predictive Value of Tests , Pulmonary Disease, Chronic Obstructive/physiopathology , Respiratory Function Tests/standards , Smoking , Statistics, Nonparametric , Surveys and Questionnaires , Spirometry/statistics & numerical data
SELECTION OF CITATIONS
SEARCH DETAIL