Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Rev. Col. Bras. Cir ; 37(1): 052-057, ene.-feb. 2010. graf, ilus, tab
Article in Portuguese | LILACS | ID: lil-554492

ABSTRACT

OBJETIVO: Avaliar a diferença do comportamento mecânico de tendões flexores solidarizados e não solidarizados para verificar se a solidarização tem função efetiva. MÉTODOS: Vinte e quatro tendões digitais bovinos frescos foram usados. Para determinar a área da secção transversal utilizou-se alginato. Dez tendões foram solidarizados seguindo as orientações do fabricante; outros 10 pares não. Foram desenvolvidas garras para fixação dos enxertos à máquina universal para simulação da fixação, sendo a superior bipartida e de passagem controlada dos pinos e a inferior com dentes alternados. RESULTADOS: A carga máxima dos corpos de prova não solidarizados foi de 849,4 N ± 386,8 a área 30,4 mm²± 7,7, tensão de 29 ± 17 Mpa. Os solidarizados obtiveram carga máxima de 871,8 N ± 484,9 área 35 mm²± 5,8, tensão de 24 ± 10 Mpa. Não houve diferença estatística entre os dois grupos (p>0,05). CONCLUSÃO: A distribuição de probabilidade mostra que para 400 N os tendões não solidarizados apresentam confiabilidade de 83,8 por cento e os solidarizados de 78,5 por cento por cento.


OBJECTIVE:To evaluate the difference of the mechanical behavior of bended tied (sewed) and not tied hamstring tendons in order to evaluate if it has any effective function. METHODS: Twenty-four fresh bovine digital tendons had been used. Alginate to determine the area of the tendon transversal section was used. Ten bovine tendons had been bended and tied following the manufacturer orientation, ten others pairs had not been tied. Claws had been developed for the grafts fixation to the universal machine, for the setting simulation. The superior one was characterized to be bipartite and to have controlled passage for the pins and the inferior claw is characterized to have alternating teeth. RESULTS: The maximum load of the not tied samples of the test was 849,4 N ± 386,8 the area was 30,4 mm² ± 7,7, and 29 ± 17 Mpa of tension. The tied ones had gotten maximum load of 871,8 N ± 484,9, area of 35 mm² ± 5,8, and 24 ± 10 Mpa of tension. It did not have statistical difference between the two groups (p>0,05). CONCLUSION: The probability distribution showed that with 400 N the not tied tendons represents 83,8 percent of trustworthiness and the tied ones represents 78,5 percent.


Subject(s)
Animals , Cattle , Anterior Cruciate Ligament/surgery , Suture Techniques , Tendons/surgery , Anterior Cruciate Ligament/physiology , Biomechanical Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL