Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Year range
1.
Braz. oral res ; 21(1): 51-57, Jan.-Mar. 2007. ilus, tab
Article in English | LILACS | ID: lil-444562

ABSTRACT

This in vitro study was designed to compare the forces generated by commercially available elastomeric chains and NiTi closed coil springs, and to determine their force decay pattern. Forty elastomeric chains and forty NiTi closed coil springs were divided into 4 groups according to the following manufacturers: (1) Morelli®, (2) Abzil®, (3) TP Orthodontics® and (4) American Orthodontics®. The specimens were extended to twice their original length and stored in artificial saliva at 37°C. Initial force was measured by means of an Instron universal testing machine and then at 1, 4, 7, 14, 21, and 28 days. The results revealed that the elastomeric chains delivered a mean initial force of 347 g for Morelli®, 351 g for American Orthodontics®, 402 g for Abzil®, and 404 g for TP Orthodontics®. The NiTi closed coil springs generated a mean initial force of 196 g for American Orthodontics®, 208 g for TP Orthodontics®, 216 g for Abzil®, and 223 g for Morelli®. The mean percentage of force decay observed after 28 days for the elastomeric chains was 37.4 percent for TP Orthodontics®, 48.1 percent for American Orthodontics®, 65.4 percent for Morelli®, and 71.6 percent for Abzil®. After 28 days, the NiTi closed coil springs presented a mean percentage of force decay of 22.6 percent for American Orthodontics®, 29.8 percent for Abzil®, 30.6 percent for Morelli®, and 45.8 percent for TP Orthodontics®. At the end of the study, significant differences were observed between the elastomeric chains and the NiTi closed coil springs. The results indicated that the studied NiTi closed coil springs are more adequate for dental movement than the elastomeric chains.


Este estudo in vitro foi delineado para comparar a força gerada por cadeias elastoméricas e por molas fechadas de NiTi comercialmente disponíveis e para determinar seu padrão de degradação de forças. Para tal, 40 segmentos de cadeia elastomérica e 40 molas fechadas de NiTi foram divididas em 4 grupos de acordo com a marca comercial: (1) Morelli®, (2) Abzil®, (3) TP Orthodontics® e (4) American Orthodontics®. As amostras foram distendidas ao dobro de seu comprimento original e imersas em solução de saliva artificial a 37°C. Uma máquina de ensaio (Instron) foi utilizada para aferir a força inicial e em 1, 4, 7, 14, 21 e 28 dias. Os resultados mostraram que as cadeias elastoméricas liberaram uma força média inicial de 404 g para a marca TP Orthodontics®, 402 g para Abzil®, 351 g para American Orthodontics® e 347 g para Morelli®. As molas fechadas de NiTi geraram uma força média inicial de 223 g para a marca Morelli®, 216 g para Abzil®, 208 g para TP Orthodontics® e 196 g para American Orthodontics®. A percentagem média de degradação da força após 28 dias para as cadeias elastoméricas foi de 37,4 por cento para TP Orthodontics®, 48,1 por cento para American Orthodontics®, 65,4 por cento para Morelli® e 71,6 por cento para Abzil®. A percentagem média de degradação da força após 28 dias para as molas fechadas de NiTi foi de 22,6 por cento para American Orthodontics®, 29,8 por cento para Abzil®, 30,6 por cento para Morelli® e 45,8 por cento para TP Orthodontics®. Ao final do experimento, observaram-se diferenças significantes entre as cadeias elastoméricas e as molas fechadas de NiTi. Os resultados permitem recomendar as molas fechadas de NiTi estudadas como dispositivos mais adequados para movimentação dentária do que as cadeias elastoméricas.


Subject(s)
Dental Alloys/chemistry , Nickel/standards , Orthodontic Appliance Design , Orthodontic Wires/standards , Polymers/standards , Titanium/standards , Analysis of Variance , Body Temperature , Elasticity , Nickel/chemistry , Stress, Mechanical , Stainless Steel/chemistry , Tensile Strength , Titanium/chemistry
2.
Ortodontia ; 37(3): 8-13, set.-dez. 2004. ilus, graf, tab
Article in Portuguese | LILACS, BBO | ID: lil-542238

ABSTRACT

O objetivo desse trabalho foi avaliar radiograficamente a mudança do espaço decorrente do uso do aparelho ortopédico de Herbst em adolescentes com retrognatismo mandibular. A amostra constou das telerradiografias em norma lateral referente a 22 pacientes (Idade média de 12 anos e 10 meses, Desvio padrão + - 0,94) e analisadas as diferenças do espaço aéreo posterior (EAP) e distância do osso hióide ao plano mandibular (H-Pm) nos tempos: inicial (T1), seis meses(T2)e um ano (T3) de tratamento com aparelho de Herbst. Os resultados mostraram que a grandeza cefalométrica EAP foi maior nos tempos T2 e T3, quando comparado ao tempo T1 (p< 0,001). A grandeza cefalométrica da distância do osso hióide ao plano mandibular (H-Pm) não mostrou diferença de valores nos diferentes tempos (p=0,985). Com base nos resultados podemos concluir, que embora não houvesse diferença na medida H-Pm o uso do aparelho de Herbest foi eficiente no aumento do espaço aéreo faríngeo posterior em pacientes com retrognatismo mandibular.


Ain of this study was to report radiographic change in pharyngeal upper airway with Herbst mandibular advancement device in adolescents with mandibular retrognastism. The sample was composed of cephalometric roentgenograms obtained in 22 patients (Mean age 12.89 +- 0.94 years) and evaluated the differences of posterior airway space (PAS) and hyoid bone to mandibular plane distance in times: preoperative (T1), six months (T2) and one year (T3) of treatment with Herbst appliance. Results showed that cephalometric measurements of the distance between the hyoid bone and the mandible (MP-H) don’t increase in different times (p=0,985). In these results our conclusion is that. Herbst appliance was efficient in increased pharyngeal upper airway in patients with mandibular retrognatism.


Subject(s)
Humans , Male , Female , Child , Adolescent , Orthotic Devices , Orthodontics , Pharynx , Retrognathia , Orthodontic Space Closure
3.
Ortodontia ; 35(2): 28-34, abr.-jun. 2002. ilus, tab
Article in Portuguese | LILACS | ID: lil-318516

ABSTRACT

Aprimorar e simplificar o processo de colagem de braquetes sobre os dentes constitui uma grande vantagem nos tratamentos ortodônticos. Como resultado da evoluçäo de materiais desenvolvidos com essa finalidade, recentemente foi introduzido no mercado o "Self Etching Primer" (SEP) que conjuga o agente condicionante (ácido) com o primer em uma única soluçäo ácido/primer, substituindo o uso convencional de ácido e primer separadamente. Para avaliar a resistência à traçäo observada quando utilizado o SEP produzido pela (3M-Unitek), o "Transbond Plus Self Etching Primer", realizamos o presente estudo in vitro, colando braquetes sobre pré-molares humanos extraídos com finalidade ortodôntica e armazenados convenientemente. Após limpar a superfície vestibular dos dentes com taça de borracha, pedra pomes e água, foi aplicado o SEP conforme recomendado pelo fabricante, durante 3 segundos e removido o excesso da soluçäo com um suave jato de ar. Em seguida a resina Transbond XT foi aplicada sobre a base do braquete e o conjunto posicionado no centro da coroa clínica dos dentes, e nesta posiçäo, aplicada força com a agulha de Gillmore e fotopolimerizada a resina. O teste de traçäo foi realizado usando a máquina para testes de traçäo INSTRON UNIVERSAL (modelo 4442-C6600, Canton, MA, USA). Os resultados do nosso estudo in vitro indicam uma resistência à traçäo média de 61,12 Newtons equivalentes a 6,25 MPa D.P. 1,61, valor considerado perfeitamente adequado porque se encontra dentro dos valores ótimos preconizados na literatura especializada. Baseados nesse resultado podemos afirmar que o "Transbond Plus Self Etching Primer" (3M-Unitek), pode ser utilizado com confiança, tendo como vantagem a simplificaçäo do procedimento de colagem e a diminuiçäo significativa do tempo clínico


Subject(s)
Dental Bonding , Orthodontic Brackets , Orthodontics
4.
Rev. dent. press ortodon. ortop. maxilar ; 7(3): 105-114, maio-jun. 2002. ilus
Article in Portuguese | LILACS, BBO | ID: lil-329249

ABSTRACT

Este trabalho teve por finalidade fazer um levantamento da literatura especializada sobre a distraçäo osteogênica (DO). Embora a primeira publicaçäo na área odontológica data de 1973, só na década de 90 este método tornou-se mais popular. Desde entäo, vários autores realizaram estudos experimentais e aplicaram esta técnica clinicamente com a intençäo de melhorar os resultados das cirurgias convencionais e ortopédicas para o tratamento das deformidades faciais. Esta técnica está fundamentada em sólidos princípios biológicos e biomecânicos, amplamente estudados. Este procedimento tem demonstrado ser de grande utilidade nos casos de deformidades dentofaciais severas


Subject(s)
Humans , Male , Female , Congenital Abnormalities , Face , Osteogenesis , Facial Asymmetry , Surgery, Oral
5.
Rev. dent. press ortodon. ortop. maxilar ; 6(2): 33-40, mar.-abr. 2001. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-298450

ABSTRACT

O presente estudo objetivou avaliar as características cefalométricas do complexo crânio facial de indivíduos CI II div. 1ª obtidas pelas análises de McNamara Jr. e Padräo USP, e compará-las com as características morfológicas da face obtidas por meio da análise facial subjetiva, em um grupo de 30 indivíduos masculinos e femininos, leucodermas, com idades entre 12 e 16anos. Cefalometricamente a amostra analisada demonstrou perfis esqueléticos convexos; maxilas bem posicionadas e mandíbulas retruídas em relaçäo à base do crânio; incisivos superiores e inferiores inclinados e protruídos e suas bases ósseas; acentuadas sobressaliências e leves sobremordidas. O exame facial subjetivo demonstrou a participaçäo da maxila em 3 casos (10 por cento); mandíbula isolada em 13 casos (43,3 por cento); maxila e mandíbula associadas em 13 casos (43,3 por cento); e maxila e mandíbula consideradas bem posicionadas em apenas 1 caso (3,3 por cento). A avaliaçäo subjetiva testada em termos de concordância com os achados da cefalometria para a posiçäo de maxila e mandíbula demonstrou ausência de significância estatística, apesar da razoável ocorrência entre os exames


Subject(s)
Humans , Male , Female , Adolescent , Cephalometry , Malocclusion, Angle Class II , Skull
6.
Ortodontia ; 34(1): 36-42, jan.-abr. 2001. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-298468

ABSTRACT

As mudanças sagitais decorrentes do tratamento com aparelhos ortopédicos funcionais das maloclusöes Classe II, divisäo 1ª têm sido amplamente estudadas; porém, säo poucos os estudos publicados que avaliam o aspecto transversal. Uma vez que a relaçäo antero-posterior das bases ósseas é mudada terapeuticamente, as novas relaçöes musculares e funcionais podem afetar concomitantemente a dimensäo transversal das arcadas. Para verificar isto, realizamos um estudo sobre os modelos iniciais e finais de 31 adolescentes, divididos em dois grupos: um grupo controle composto por 13 pacientes e um grupo tratado durante 18 meses com Bionator de Balters, composto por 18 pacientes. A idade média no início do período de observaçäo foi de 10 anos e 7 meses (D.P.mais ou menos 1,3)e no término de 12 anos e 2 meses (D.P. mais ou menos 1,3). Comparamos os modelos de gesso das fases início e término, determinando as mudanças transversais nas regiöes anteriores (1§ pré-molares ou 1§ molares decíduos) e posteriores(1§ molares permanentes) das arcadas superior e inferior. Os resultados foram comparados, utilizando-se o teste "t" de Student, observando aumento estatisticamente significante ao nível de 1 por cento nas regiöes anterior superior (de 34,91mm para 36,31mm); posterior superior (de 45,01mm para 46,27mm)e posterior inferior do grupo tratado(de 46,93mm para 48,18mm). Näo foram observadas mudanças estatisticamente significantes no grupo controle em todas as regiöes e na regiäo anterior inferior do grupo tratado. Com estes resultados, achamos por bem concluir que em decorrência do crescimento transversal e também da correçäo da Classe II divisäo 1ª com este tipo de tratamento, ocorreram modificaçöes vantajosas nas dimensöes transversais nos arcos superior na regiäo anterior e posterior, enquanto que no arco inferior ocorreram modificaçöes só na regiäo posterior


Subject(s)
Humans , Male , Female , Adolescent , Child , Activator Appliances , Malocclusion, Angle Class II , Orthotic Devices , Orthodontics
7.
Säo Paulo; s.n; 1999. 152 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: lil-256333

ABSTRACT

O objetivo deste prospectivo foi realizar uma avaliaçäo radiográfica das mudanças da posiçäo do côndilo mandibular na fossa articular em decorrência do tratamento da maloclusäo de Classe II, Divisäo 1ª, quando utilizado o Aparelho Ortopédico-funcional tipo Bionator de BALTERS. A amostra constou das 38 tomografias corrigidas das ATMs nas posiçöes de MIC e repouso e das telerradiografias laterais de 19 pacientes leucodermas brasileiros em crescimento, com idade média de 10 anos e sete meses, D.P. 1,1 anos. Nas tomografias foram medidos os espaços articulares, superior, posterior e anterior e as distâncias superior, póstero-superior e ântero-superior da borda da fossa articular ao centro do côndilo. A partir destas medidas foram calculados os índices da posiçäo condilar na fossa articular. Após a análise estatística e a mediçäo das diferenças das médias obtidas no início e término do tratamento, concluiu-se que ao início do tratamento, os côndilos em MIC e em repouso encontravam-se em uma posiçäo anterior na fossa articular a após o tratamento em MIC, houve uma diminuiçäo, estatisticamente significativa, do espaço articular posterior, um aumento do espaço articular anterior e da distância ântero-superior, conseqüentemente, a posiçäo do côndilo na fossa articular sofreu um deslocamento para posterior, apresentando-se no término do tratamento em uma posiçäo mais centralizada que no início...


Subject(s)
Child , Mandibular Condyle , Orthodontic Appliances, Functional , Tomography , Malocclusion, Angle Class II
SELECTION OF CITATIONS
SEARCH DETAIL