Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
The Journal of Korean Academy of Prosthodontics ; : 8-13, 2016.
Article in Korean | WPRIM | ID: wpr-122209

ABSTRACT

PURPOSE: The aim of this study was to compare the accuracy of two different styles of mechanical implant torque wrenches before and after sterilization and repeated use. MATERIALS AND METHODS: Thirty new spring-style and friction-style mechanical implant torque wrenches from five different manufacturers were selected as subjects of study and assessed in terms of accuracy. Three manufacturers produced, spring-style (Dio, Neobiotech, Osstem) torque wrenches, and other three manufactures produced friction-style (Dentium, Osstem, Shinhung) torque wrenches. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (MGT-12, Mark-10 Corp, USA) was used to record the measurements. All torque wrenches were used repeatedly for 20 times and then sterilized. This whole procedure was repeated 100 times and all torque wrenches were retested. The collected data was analyzed using a SPSS Statistics Analysis program to evaluate the accuracy of the torque wrenches and Mann-Whitney-U test was used for a comparative analysis. RESULTS: After sterilization and repeated use procedure, results did not show any significant difference between error values in the spring-style torque wrench group. However, the results demonstrated an increase in error values within the friction-style torque wrench group (P.05). There was significant difference between the accuracy of new friction-style torque wrenches before and after 100 cycles of sterilization and repeated use (P<.05). Within the limitation of this study, spring-style torque wrenches were more accurate than friction-style torque wrenches in delivering target torque values.


Subject(s)
Infection Control , Sterilization , Torque
2.
The Journal of Advanced Prosthodontics ; : 70-74, 2016.
Article in English | WPRIM | ID: wpr-211464

ABSTRACT

In the maxillary anterior region, reconstruction of the localized alveolar ridge defect is very important in enhancing the esthetics of fixed partial denture. A 40-year-old female patient presented with a chief complaint of the inconvenience and unesthetic problem of 3-unit maxillary anterior prosthesis due to alveolar ridge resorption. After removal of old prosthesis, intraoral examination revealed moderate (buccolingually 4 mm) ridge deficiency in missing tooth region, leading to the diagnosis of Class I alveolar ridge defect. One of the reconstruction techniques to overcome this problem might be a technique that combines two types of soft tissue augmentation techniques. The purpose of this paper was to demonstrate the new combined technique of roll flap and combination onlay-interpositional graft utilized to acquire sufficient dimension of recipient area by one time of operation and to present the esthetic improvement of fixed partial denture by using this procedure in case of maxillary anterior localized ridge defect.


Subject(s)
Adult , Female , Humans , Alveolar Process , Denture, Partial, Fixed , Diagnosis , Esthetics , Prostheses and Implants , Tooth , Transplants
SELECTION OF CITATIONS
SEARCH DETAIL