Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Rev. chil. radiol ; 14(3): 154-157, 2008. ilus, tab, graf
Article in Spanish | LILACS | ID: lil-517434

ABSTRACT

Introduction: Directional vacuum-assisted stereotactic breast biopsy (DVAB), represents an excellent method for obtaining pathological diagnosis, being in many cases an alternative to surgery. Objectives: To present our 2-year experience in DVAB at the University of Chile's Clinical Hospital. Materials and methods: a descriptive retrospective study of DVAB was conducted in our Hospital from March 2005 to November 2007. Morphology of lesions, BI-RADS classification, pathology reports, complications as well as epidemiological data were recorded. Results: We included 79 patients with 95 lesions. Mean age 55 years. Of the 95 biopsies, 95.7 percent were microcalcifications. The sensitivity was 92.8 percent and specificity 100 percent. The positive predictive value was 100 percent, while negative PVwas 98.7 percent, with 8 percent of subestimation and complication rate of 3,1 percent. Conclusions: Our results confirm the advantages of said procedure in our Center, proving DVAB as highly reliable, with good histological correlation and minimal complications.


Introducción: La biopsia estereotáxica digital mamaria (BED), representa un excelente método para obtener diagnóstico histológico, siendo alternativa de elección frente a la cirugía en muchos casos. Objetivo: Presentar nuestra experiencia en la aplicación de la BED en el Hospital Clínico de Universidad de Chile. Material y método: Estudio descriptivo, retrospectivo de BED realizadas en el Hospital Clínico de la Universidad de Chile (marzo 2005-noviembre 2007). Se registró morfología de las lesiones, clasificación BI-RADS, informes de anatomía patológica, complicaciones y datos epidemiológicos. Resultados: Se incluyó a 79 pacientes con 95 lesiones. Edad promedio 55 años. De las 95 biopsias, 95,7 por ciento correspondieron a microcalcificaciones. La sensibilidad fue 92,8 por ciento y la especificidad 100 por ciento. El valor predictivo positivo fue 100 por ciento y negativo 98,7 por ciento. La subestimación fue de 8 por ciento y la tasa de complicaciones 3,1 por ciento. Conclusiones: Nuestros resultados confirman las ventajas del procedimiento en nuestro Centro, demostrando la BED como altamente confiable, con buena correlación histológica y mínimas complicaciones.


Subject(s)
Humans , Female , Adult , Middle Aged , Biopsy, Needle/methods , Breast Diseases/pathology , Stereotaxic Techniques , Predictive Value of Tests , Retrospective Studies , Sensitivity and Specificity , Vacuum
2.
Rev. chil. radiol ; 14(3): 151-153, 2008. ilus, tab, graf
Article in Spanish | LILACS | ID: lil-517435

ABSTRACT

The purpose of this study was to determine the frequency, concordance and discordance of breast lesions during automated core biopsy. A US-guided 14 -gauge automated core needle biopsy was performed on 188 lesions. Only in 1 of 120 benign diagnosed cases imaging-histologic discordance was present. This lesion underwent surgical excision and the case was diagnosed as having carcinoma in situ, as a definitive histological diagnosis. Assessment of correlation between imaging studies and histologic findings, as well as determinaron of concordance, are required to minimize diagnostic errors.


El propósito de nuestro estudio fue determinar la frecuencia, concordancias y discordancias de las lesiones mamarias. Se realizaron 188 biopsias core con aguja de 14G. Sólo 1 de las 120 lesiones benignas diagnosticadas fue discordante; se recomendó escisión quirúrgica cuyo resultado definitivo demostró carcinoma in situ. Para minimizar errores diagnósticos, se requiere evaluar la correlación entre las imágenes y el resultado histológico, además de establecer la concordancia.


Subject(s)
Humans , Female , Adolescent , Adult , Middle Aged , Aged, 80 and over , Biopsy, Needle , Breast Diseases/diagnosis , Breast Diseases/pathology , Diagnostic Imaging , Breast Neoplasms/diagnosis , Breast Neoplasms/pathology , Retrospective Studies
3.
Rev. chil. salud pública ; 5(1): 19-23, 2001. tab
Article in Spanish | LILACS | ID: lil-348117

ABSTRACT

Con el fin de evaluar el desarrollo psicomotor en lactantes y preescolares de un Consultorio de Atención Primaria en la ciudad de Los Andes y establecer la relación de éste con otros estudios similares realizados a nivel nacional y con algunos factores de riesgo ambiental como: estado nutricional, edad y escolaridad materna, se realizó un estudio con 487 niños sanos entre 0 y 4 años de ambos sexos que asistieron a control sano durante el año 1999. A ésta muestra se le realizó evaluación del desarrollo psicomotor con los test de Soledad Rodríguez y TEPSI de acuerdo a la edad del niño. En los lactantes estudiados un 2,5 por ciento presentó déficit del desarrollo psicomotor valor inferior a lo encontrado en bibliografía y los preescolares presentaron un 30,5 por ciento de desarrollo subnormal valor semejante a la encontrada en Chile. En ambos grupos no se encontró relación con los factores de riesgo considerados; por lo que probablemente existen otras variables más importantes que influyen en el desarrollo psicomotor del niño y que no fueron consideradas en este estudio


Subject(s)
Humans , Male , Child, Preschool , Child , Infant , Female , Psychomotor Performance , Body Weight , Child Care , Congenital Abnormalities , Biological Factors/adverse effects , Hypothyroidism , Kernicterus , Meningitis , Nervous System , Nutritional Status , Phenylketonurias , Risk Factors , Socioeconomic Factors
SELECTION OF CITATIONS
SEARCH DETAIL