Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Einstein (Säo Paulo) ; 11(3): 350-356, jul.-set. 2013. graf, tab
Article in Portuguese | LILACS | ID: lil-688640

ABSTRACT

OBJETIVO: Avaliar a incidência de eventos adversos cardíacos maiores (morte cardíaca, infarto agudo do miocárdio ou necessidade de nova revascularização do vaso-alvo) em 1 ano em pacientes do "mundo real". MÉTODOS: O registro EINSTEIN é um estudo observacional prospectivo, unicêntrico, que incluiu consecutivamente 103 pacientes (152 lesões) tratados com o stent BiomatrixTM, eluidor de biolimus A9 e polímero biodegradável. RESULTADOS: A média das idades foi de 65,0±12,4 anos; o gênero masculino representou 83,5% dos pacientes; e 37,9% deles eram diabéticos. Em 1 ano, eventos adversos cardíacos maiores ocorreram em 11,7% dos pacientes, incluindo 2,9% de morte cardíaca, 4,9% de infarto agudo do miocárdio sem supradesnivelamento do segmento ST e 3,9% de revascularização do vaso-alvo. Trombose de stent esteve presente em apenas 1% (1 paciente) após o seguimento clínico de 1 ano. CONCLUSÃO: O presente registro sugere que os novos stents farmacológicos eluidores de biolimus A9 com polímero biodegradável são seguros e eficazes em pacientes da prática clínica diária, com baixas taxas de eventos adversos cardíacos maiores no longo prazo.


OBJECTIVE: To evaluate the incidence of major adverse cardiac events (cardiac death, or acute myocardial infarct, or target vessel revascularization) at one year in "real world" patients. METHODS: The EINSTEIN registry is an observational, prospective, single center study that consecutively included 103 patients (152 lesions) treated with the BiomatrixTM stent, a biolimus A9-eluting stent with biodegradable polymer. RESULTS: The mean age was 65.0±12.4 years; male gender represented 83.5% of the patients; and 37.9% of them were diabetic. At one-year, major adverse cardiac events occurred in 11.7% of the patients, including 2.9% of cardiac death, 4.9% of with non ST- segment elevation acute myocardial infarction, and 3.9% of target vessel revascularization. Stent thrombosis occurred in only 1% (1 patient) at one-yearfollow-up. CONCLUSION: The present Registry suggests that new generation biolimus A9 drug-eluting stents are safe and effective in a "real world", all-comers patients, showing low rates of major cardiac adverse events on long-term follow-up.


Subject(s)
Biocompatible Materials , Coronary Artery Disease , Drug Delivery Systems , Drug-Eluting Stents , Polymers/chemical synthesis , Sirolimus/analogs & derivatives
SELECTION OF CITATIONS
SEARCH DETAIL