Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Indian J Ophthalmol ; 2023 Aug; 71(8): 3085-3090
Article | IMSEAR | ID: sea-225184

ABSTRACT

Purpose: To characterize the relationship between diabetic macular ischemia (DMI) delineated by optical coherence tomography angiography (OCTA) and microaneurysms (MAs) identified by fundus fluorescein angiography (FFA). Methods: Patients with diabetic retinopathy (DR) who underwent OCTA and FFA were retrospectively identified. FFA images were cropped and aligned with their respective OCTA images using i2k Align Retina software (Dual?Align, Clifton Park, NY, USA). Foveal avascular zone (FAZ) and ischemic areas were manually delineated on OCTA images, and MAs were marked on the corresponding FFA images before overlaying paired scans for analysis (ImageJ; National Institutes of Health, Bethesda, MD, USA). Results: Twenty?eight eyes of 20 patients were included. The average number of MAs identified in cropped FFA images was 127 ± 42. More DMI was noted in the superficial capillary plexus (SCP; 36 ± 13%) compared to the deep capillary plexus (DCP; 28 ± 14%, P < 0.001). Similarly, more MAs were associated with ischemic areas in SCP compared to DCP (92.0 ± 35.0 vs. 76.8 ± 36.5, P < 0.001). Most MAs bordered ischemic areas; fewer than 10% localized inside these regions. As DMI area increased, so did associated MAs (SCP: r = 0.695, P < 0.001; DCP: r = 0.726, P < 0.001). Density of MAs surrounding FAZ (7.7 ± 6.0 MAs/mm2) was similar to other DMI areas (SCP: 7.0 ± 4.0 MAs/mm2, P = 0.478; DCP: 9.2 ± 10.9 MAs/mm2, P = 0.394). Conclusion: MAs identified in FFA strongly associate with, and border areas of, DMI delineated by OCTA. Although more MAs are localized to SCP ischemia, the concentration of MAs associated with DCP ischemia is greater. By contrast, few MAs are present inside low?flow regions, likely because capillary loss is associated with their regression.

2.
Indian J Ophthalmol ; 2014 July ; 62 (7): 788-791
Article in English | IMSEAR | ID: sea-155702

ABSTRACT

Purpose: To study the relationship between the axial length and personal A‑constant for the 1‑piece Tecnis (Abbott ZCB00), AcrySof MA60AC (Alcon) and the Quatrix aspheric preloaded (CROMA) intraocular lenses (IOL). Materials and Methods: Patients matching the inclusion criteria were further subdivided according to the implanted IOL in this prospective comparative study. The obtained refractive outcomes were introduced into the formula installed in the biometry machine (Humphrey model 820 ultrasonic biometer) to obtain the personal A‑constant for each eye. Polynomial regression analysis was done to study the individualized A‑constant for each type of IOL in relation to preoperative axial length measurement. Results: Two hundred and forty five eyes of 186 patients were enrolled into this study, of whom 73 eyes with Tecnis 1‑piece, 116 eyes with MA60AC, and 56 eyes with Quatrix. The median of personalized A‑constant for Tecnis 1‑piece, MA60AC, and Quatrix were 119.21 (SD 1.3, Std. Mean error 0.15), 119 (SD 1.2, Std. Mean error 0.11) and 120.4 (SD 1.2, Std. Mean error 0.16) respectively. Regression plots for the same range of axial length among all the groups showed that the Tecnis1 group followed the same pattern of the Quatrix group in which there was a linear relationship of a trend towards myopia when the axial length had increased and a hyperopic shift when decreased. This relationship changed into a plateau when the axial length became in the range of 23.5 mm to 27 mm in the MA60AC group. Conclusions: Personal A‑constant follows different trends with different IOLs even for the same range of axial length.

SELECTION OF CITATIONS
SEARCH DETAIL