Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Arch. cardiol. Méx ; 75(4): 435-440, oct.-dic. 2005. ilus, tab
Article in Spanish | LILACS | ID: lil-631923

ABSTRACT

Objetivo: Analizar la utilidad de la resonancia magnética para el diagnóstico morfológico en las cardiopatías congénitas complejas comparada con el ecocardiograma transtorácico. Método: Se incluyeron 45 pacientes con sospecha clínica de cardiopatía congénita grave, se les realizó una resonancia magnética y ecocardiograma transtorácico y se comparó anatomía y tamaño de cavidades cardíacas. Para el análisis se empleó estadística descriptiva y análisis de Bland-AItman para la concordancia entre ambos métodos. Resultados: No hubo diferencias significativas en mediciones obtenidas por ambos métodos, excepto en la fracción de expulsión del ventrículo izquierdo (66.56 ± 9.47 por ECO vs 52.32 ± 13.85 por RM, p = 0.0001) y la medición del diámetro de la rama izquierda de la arteria pulmonar (9.77 ± 6.80 por ECO vs 13.83 ± 8.46 por RM, p = 0.05). La sensibilidad, especificidad y los valores predictivos de la RM fueron elevados para analizar la conexión AV y VA, no así para el situs atrial y los drenajes venosos (pulmonar y sistémico) donde el ECO tiene baja resolución. La concordancia de las mediciones de la FE, índice de McGoon y tamaño del VD mostró pocos valores extremos. Conclusiones: La RM y el ECO son similares para el diagnóstico morfológico de las cardiopatías congénitas graves, pero la RM puede superar al ECO en la visualización de estructuras extracardíacas.


Objective: To analyze the usefulness of magnetic resonance for the morphological diagnosis in complex congenital cardiopathies and compare it with the transthoracic echocardiogram. Method: We included 45 patients with clinical suspicion of severe congenital cardiopathy A magnetic resonance and a transthoracic echocardiogram were performed and the anatomy and size of the cardiac cavities were compared. Descriptive statistics were used and Bland-Altman test was used to analyze concordance between both methods. Results: There were no significant differences in the measures obtained with either method, except for the left ventricle ejection fraction (66.56 ± 9.47 with ECO vs 52.32 ± 13.85 with MR, p = 0.0001) and for diameter of the left branch of the pulmonary artery (9.77 ± 6.80 with ECO vs 12.83 ± 8.46 with MR, p = 0.05). The sensitivity, specificity, and predictive values of MR were high to analyze the AV and VA connection, but not for the atrial sinus and the venous drainages (pulmonary and systemic). Concordance of ejection fraction measures, McGoon index, and size of VD revealed few extreme values. Conclusions: MR and ECO are similar for the morphological diagnosis of severe congenital cardiopathies, but MR can be better than ECO for the visualization of extracardiac structures.


Subject(s)
Adolescent , Child , Humans , Heart Diseases/congenital , Heart Diseases/diagnosis , Magnetic Resonance Imaging , Heart Diseases , Severity of Illness Index
SELECTION OF CITATIONS
SEARCH DETAIL