Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Main subject
Language
Year range
1.
Rev. Soc. Colomb. Oftalmol ; 54(1): 29-38, 2021. ilus
Article in Spanish | LILACS, COLNAL | ID: biblio-1451240

ABSTRACT

Introducción: La gonioscopía es la técnica utilizada para diagnosticar la sospecha de cierre angular primario (SCAP). Sin embargo, es una medida subjetiva, a diferencia de la tomografía óptica coherente de segmento anterior (OCT-SA). Se realizó un estudio midiendo los parámetros estereoscópicos por OCT-SA y su correlación con la gonioscopía. Objetivo: Comparar la gonioscopía y los parámetros por OCT-SA en ojos con ángulo estrecho y abierto, y evaluar la reproducibilidad intraobservador de estos parámetros. Método: Estudio observacional, analítico, descriptivo y longitudinal. Se recolectó la información de los pacientes valorados en la consulta de glaucoma entre marzo y junio de 2019 sin antecedente de cirugía ni láser ocular a quienes se solicitó OCT-SA. Resultados: De 131 ojos, el 28.25% tenían ángulos estrechos y el 68.7% abiertos. La distancia de apertura del ángulo 500 (AOD) promedio nasal fue de 210 µm (rango intercuartílico [RIQ]: 98-275.5) y el temporal fue de 214 µm (RIQ: 130.5-289). El área del espacio del iris trabecular área 500 (TISA) promedio nasal fue de 0.070 mm2 (RIQ: 0.034-0.093) y el temporal fue de 0.068 mm2 (RIQ: 0.038-0.093). El ángulo del iris trabecular (TIA) nasal fue de 23.77° (RIQ: 12.11-29.92) y el temporal fue de 23.46° (RIQ: 14.37-30.45). Cuanto más abiertos están los ángulos por gonioscopía, mayor área de TISA, TIA y AOD. Existe una buena reproducibilidad intraobservador respecto al AOD nasal, con un coeficiente de concordancia de 0.956 (intervalo de confianza del 95% [IC95%]: 0.94- 0.97), y para el AOD temporal de 0.940 (IC95%: 0.92-0.96). Respecto al TISA nasal, el coeficiente de concordancia fue de 0.956 (IC95%: 0.9-0.97), y para el temporal de 0.946 (IC95%: 0.93-0.96). Conclusiones: La OCT-SA tiene una buena correlación con la gonioscopía y una buena reproducibilidad intraobservador. Sin embargo, sigue siendo una ayuda diagnóstica que no reemplaza la evaluación clínicaIntroducción: La gonioscopía es la técnica utilizada para diagnosticar la sospecha de cierre angular primario (SCAP). Sin embargo, es una medida subjetiva, a diferencia de la tomografía óptica coherente de segmento anterior (OCT-SA). Se realizó un estudio midiendo los parámetros estereoscópicos por OCT-SA y su correlación con la gonioscopía. Objetivo: Comparar la gonioscopía y los parámetros por OCT-SA en ojos con ángulo estrecho y abierto, y evaluar la reproducibilidad intraobservador de estos parámetros. Método: Estudio observacional, analítico, descriptivo y longitudinal. Se recolectó la información de los pacientes valorados en la consulta de glaucoma entre marzo y junio de 2019 sin antecedente de cirugía ni láser ocular a quienes se solicitó OCT-SA. Resultados: De 131 ojos, el 28.25% tenían ángulos estrechos y el 68.7% abiertos. La distancia de apertura del ángulo 500 (AOD) promedio nasal fue de 210 µm (rango intercuartílico [RIQ]: 98-275.5) y el temporal fue de 214 µm (RIQ: 130.5-289). El área del espacio del iris trabecular área 500 (TISA) promedio nasal fue de 0.070 mm2 (RIQ: 0.034-0.093) y el temporal fue de 0.068 mm2 (RIQ: 0.038-0.093). El ángulo del iris trabecular (TIA) nasal fue de 23.77° (RIQ: 12.11-29.92) y el temporal fue de 23.46° (RIQ: 14.37-30.45). Cuanto más abiertos están los ángulos por gonioscopía, mayor área de TISA, TIA y AOD. Existe una buena reproducibilidad intraobservador respecto al AOD nasal, con un coeficiente de concordancia de 0.956 (intervalo de confianza del 95% [IC95%]: 0.94- 0.97), y para el AOD temporal de 0.940 (IC95%: 0.92-0.96). Respecto al TISA nasal, el coeficiente de concordancia fue de 0.956 (IC95%: 0.9-0.97), y para el temporal de 0.946 (IC95%: 0.93-0.96). Conclusiones: La OCT-SA tiene una buena correlación con la gonioscopía y una buena reproducibilidad intraobservador. Sin embargo, sigue siendo una ayuda diagnóstica que no reemplaza la evaluación clínica


Introduction: Gonioscopy is the technique used to diagnose primary angle closure suspect (PACS). Nevertheless, it is a subjective measure compared to anterior segment coherent optical tomography (AS-OCT). A study was performed by measuring the stereoscopic parameters with AS-OCT and correlating them with gonioscopy. Objective: To compare gonioscopy and AS-OCT parameters in eyes with closed and open angle. Moreover, to evaluate intraobserver reproducibility of those parameters. Method: Observational, analytical descriptive longitudinal study. Data was collected from patients who attended glaucoma service between March and June 2019 and had an AS-OOCT done. Patients were excluded if they had history of laser or intraocular surgery. Results: Out of 131 eyes, 28.25% had closed angles and 68.7% open angles. The average nasal angle opening distance 500 (AOD) was 210 µm ICR (98 ­ 275.5) and the temporal was 214 µm ICR (130.5 ­ 289). The average nasal trabecular iris space area 500 (TISA) was 0.070 mm2 ICR (0.034 ­ 0.093) and the temporal was 0.068 mm2 ICR (0.038 ­ 0.093). The nasal trabecular iris angle (TIA) was 23.77º ICR (12.11 ­ 29.92) and the temporal was 23.46º ICR (14.37 ­ 30.45). The wider the angles by gonioscopy, the greater the area of TISA, TIA and AOD. A good nasal AOD intraobserver reproducibility was observed with a concordance coefficient of 0.956 (IC 95%: 0.94 ­ 0.97) and temporal AOD of 0.940 (0.92 ­ 0.96). Regarding the nasal TISA, the concordance coefficient was 0.956 (IC 95%: 0.9 ­ 0.97) and temporal TISA was 0.946 (IC 95: 0.93 ­ 0.96). Conclusions: AS-OCT has a strong correlation with gonioscopy and a good intraobserver reproducibility. However, it remains as a diagnostic aid that does not substitute clinical evaluation.


Subject(s)
Humans , Male , Female , Middle Aged
2.
Rev. Soc. Colomb. Oftalmol ; 52(2): 110-116, 2019. ilus., tab., graf.
Article in Spanish | LILACS, COLNAL | ID: biblio-1094901

ABSTRACT

Introducción: el encapsulamiento de la ampolla o también llamado "quiste de Tenon" alrededor del dispositivo puede comprometer el funcionamiento valvular, aumentando la presión intraocular y así requiriendo procedimientos quirúrgicos adicionales. Objetivo: describir la eficacia y seguridad de la resección de quiste encapsulado en implante valvular de Ahmed en el control de la presión intraocular. Diseño de estudio: estudio observacional, retrospectivo, serie de casos. Método: se hizo un análisis de los pacientes a los que se les realizó resección de quiste encapsulado con un seguimiento a 6 meses, se excluyeron pacientes con antecedente de procedimiento ciclodestructivo, agudeza visual no percepción de luz, alteración del estado de conciencia, cirugía combinada y /o seguimiento postoperatorio menor de 3 meses. Resultados: se analizaron 14 ojos de los cuales 9 (64.3%) eran mujeres. El promedio de edad fue 56.1 con un rango entre 14 ­ 83 años. La presión intraocular preoperatoria promedio fue 26.7± 6.6 mmHg con una reducción estadísticamente significativa desde el primer día posoperatorio 9.8 ± 0.93 mmHg y al sexto mes 13.7 ± 0.94 mmHg (p 0.005). En el primer mes posoperatorio se logró reducción significativa en el número de medicamentos hipotensores (p 0.003), el cual se estabilizó al tercer mes y al sexto mes no presentó diferencia estadísticamente significativa (p 0.078). Conclusión: la resección de quiste encapsulado es un procedimiento efectivo para lograr el control de la presión intraocular en pacientes con glaucomas refractarios y/o no controlados con pocas complicaciones asociadas.


Background: the encapsulation of the bleb or so-called (Tenon cyst) around the device can compromise valve function, increasing intraocular pressure and thus requiring additional surgical procedures. Objective: to describe the efficacy and safety of encapsulated cyst resection in Ahmed valve implant for the control of intraocular pressure. Study design: observational study, retrospective cases series. Method: an analysis was made of the patients who underwent encapsulated cyst resection between January 2016 and August 2017 with a 6-month follow-up, patients with a history of cyclodestructive procedure, visual acuity of no light perception, altered state of consciousness, combined surgery and / or postoperative follow-up of less than 3 months were excluded. Results: 14 eyes were analyzed, of which 9 (64.3%) were women. The average age was 56.1 with a range between 14 - 83 years. he average preoperative intraocular pressure was 26.7 ± 6.6 mmHg with a statistically significant reduction from the first postoperative day 9.8 ± 0.93 mmHg and at the sixth month 13.7 ± 0.94 mmHg (p 0.005). In the fi rst postoperative month there was a significant reduction in the number of hypotensive drugs (p 0.003), which stabilized at the third month and at the sixth month did not present a statistically significant difference (p 0.078). Conclusion: encapsulated cyst resection is an effective procedure to achieve control of intraocular pressure in patients with refractory and / or uncontrolled glaucoma with few associated complications.


Subject(s)
Glaucoma/surgery , Ophthalmologic Surgical Procedures , Eye Diseases , Tenon Capsule/surgery , Intraocular Pressure
SELECTION OF CITATIONS
SEARCH DETAIL