Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Mycobiology ; : 164-167, 2012.
Article in English | WPRIM | ID: wpr-729673

ABSTRACT

The effects of aeration through lid filters on the hyphal growth of Lentinula edodes (oak mushroom) in sawdust cultivation bags were investigated. The aeration treatment levels were traditional 27 mm hole cotton plugs, cotton balls and combinations of seven hole sizes x two hole positions (up and under) in the lids covering plastic bags containing 1.4 kg sawdust medium at 63% moisture that had been autoclaved for one hour and inoculated with sawdust spawn of L. edodes strain 921. Aeration treatment effects were measured based on the CO2 concentration at the 15th wk, as well as the hyphal growth rate and degree of weight loss of bags every 14 days for 15 wk. In bags with traditional cotton plugs, the CO2 concentration was 3.8 +/- 1.3%, daily mean hyphal growth was 2.3 +/- 0.6 mm and daily mean weight loss was 0.84 +/- 0.26 g. In the bags with 15 mm diameter holes, the CO2 concentration was 6.0 +/- 1.6%, daily hyphal growth was 2.8 +/- 0.2 mm and daily weight loss was 0.86 +/- 0.4 g. The bags with 15 mm holes had a higher CO2 concentration and lower water loss than bags with other hole sizes, but the hyphal growth was not significantly different from that of other bags. The weight loss of bags increased proportionally relative to the lid hole sizes. Taken together, these results indicate that traditional cotton plugs are economically efficient, but 15 mm hole lids are the most efficient at maintaining hyphal growth and controlling water loss while allowing CO2 emissions.


Subject(s)
Lentinula , Plastics , Shiitake Mushrooms , Sprains and Strains , Weight Loss
2.
Journal of Korean Academy of Conservative Dentistry ; : 20-27, 2008.
Article in Korean | WPRIM | ID: wpr-167694

ABSTRACT

The purpose of this study was to evaluate the consistency of two electronic apex locators in vitro model. Materials consisted of fifty two extracted premolars and two electronic apex locators; Root ZX (J. Morita, Osaka, Japan) and E-Magic Finder Deluxe (S-Denti, Cheonan, Korea). After access preparation, the teeth were embedded in a saline-mixed alginate model. Canal lengths of each tooth were measured at "0.5" and "Apex" mark of the apex locators, respectively so that each tooth had two measurements from 0.5 and Apex points. The file was fixed at final measurement using a glass ionomer cement. The apical 4 mm from the apex was exposed to measure the distance from the file tip to the major apical foramen of each tooth. Average distances and standard deviations were used to evaluate the consistency. Results showed that all measurements of both Root ZX and E-Magic Finder located the major foramen the range of +/- 0.5 mm level. Both apex locators showed better consistency at Apex mark than at 0.5 mark. The average distance of file tip-major foramen was - 0.18 mm at 0.5 mark and - 0.07 mm at Apex mark in Root ZX, - 0.25 mm at 0.5 mark and - 0.02 mm at Apex mark in E-Magic Finder. Standard deviation was 0.21 at 0.5 mark and 0.12 at Apex mark in Root ZX, 0.12 at 0.5 mark and 0.09 at Apex mark in E-Magic Finder.


Subject(s)
Acrylic Resins , Alginates , Bicuspid , Electronics , Electrons , Glass Ionomer Cements , Glucuronic Acid , Hexuronic Acids , Silicon Dioxide , Tooth , Tooth Apex
3.
Journal of Korean Academy of Conservative Dentistry ; : 130-137, 2007.
Article in English | WPRIM | ID: wpr-18230

ABSTRACT

This in vitro study examined the effect of surface defects on cutting blades on the extent of the cyclic fatigue fracture of HEROShaper Ni-Ti rotary files using fractographic analysis of the fractured surfaces. A total of 45 HEROShaper (MicroMega) Ni-Ti rotary files with a #30/.04 taper were divided into three groups of 15 each. Group 1 contained new HEROShapers without any surface defects. Group 2 contained HEROShapers with manufacturing defects such as metal rollover and machining marks. Group 3 contained HEROShapers that had been clinically used for the canal preparation of 4-6 molars. A fatigue-testing device was designed to allow cyclic tension and compressive stress on the tip of the instrument whilst maintaining similar conditions to those experienced in a clinic. The level of fatigue fracture time was measured using a computer connected the system. Statistical analysis was performed using a Tukey's test. Scanning electron microscopy (SEM) was used for fractographic analysis of the fractured surfaces. The fatigue fracture time between groups 1 and 2, and between groups 1 and 3 was significantly different (p 0.05). A low magnification SEM views show brittle fracture as the main initial failure mode. At higher magnification, the brittle fracture region showed clusters of fatigue striations and a large number of secondary cracks. These fractures typically led to a central region of catastrophic ductile failure. Qualitatively, the ductile fracture region was characterized by the formation of microvoids and dimpling. The fractured surfaces of the HEROShapers in groups 2 and 3 were always associated with pre-existing surface defects. Typically, the fractured surface in the brittle fracture region showed evidence of cleavage (transgranular) facets across the grains, as well as intergranular facets along the grain boundaries. These results show that surface defects on cutting blades of Ni-Ti rotary files might be the preferred sites for the origin of fatigue fracture under experimental conditions. Furthermore, this work demonstrates the utility of fractography in evaluating the failure of Ni-Ti rotary files.


Subject(s)
Edible Grain , Fatigue , Fractures, Stress , Microscopy, Electron, Scanning , Molar
4.
Journal of Korean Academy of Conservative Dentistry ; : 192-202, 2006.
Article in Korean | WPRIM | ID: wpr-174005

ABSTRACT

The purpose of this study was to examine the viability of PDL cells in rat molars by using in vivo MTT assay, which was used to compare fast cryopreservation group by liquid nitrogen (-196degrees C) with 4degrees C cold preservation group. A total of 74 Sprague-Dawley white female rats of 4 week-old with a body weight of 100 grams were used. The maxillary left and right, first and second molars were extracted as atraumatically as possible under ketamine anesthesia. Ten teeth of each group were divided as six experimental groups depending upon the preservation. Cryopreservation groups were Group 1 (5% DMSO 6% HES in F medium), Group 2 (10% DMSO in F medium), Group 3 (5% DMSO 6% HES in Viaspan(R)), Group 4 (10% DMSO in Viaspan(R)) which were cryopreserved for 1 week and cold preservation groups were Group 5 (F medium), Group 6 (Viaspan(R)) at 4degrees C for 1 week. Immediate extraction group was used as a control. After preservation and thawing, the in vivo MTT assay was processed. Two way ANOVA and Duncan's Multiple Range Test was performed at the 95% level of confidence. Another 2 teeth of each group were treated as the same manner and frozen sections 10 microm thick for microscopic observation. The value of optical density obtained after in vivo MTT analysis was divided by the value of eosin staining for tissue volume standardization. Group 1, 2 had significantly higher optical density than Group 3 and 4 which had the lowest OD value. Group 6 had higher OD value than in Group 5 (P < 0.05). Histological findings of periodontal ligament cell, after being stained with MTT solution were consistent with the in vivo MTT assay results. In this study, the groups which were frozen with DMSO as a cryoprotectant and the groups with F medium showed the best results.


Subject(s)
Animals , Female , Humans , Rats , Anesthesia , Body Weight , Cell Survival , Cryopreservation , Dimethyl Sulfoxide , Eosine Yellowish-(YS) , Frozen Sections , Ketamine , Molar , Nitrogen , Periodontal Ligament , Rats, Sprague-Dawley , Tooth
5.
Journal of Korean Academy of Conservative Dentistry ; : 267-272, 2004.
Article in Korean | WPRIM | ID: wpr-43678

ABSTRACT

The purpose of this in vitro study was to evaluate the effect of surface defects and cross-sectional configuration of NiTi rotary files on the fatigue life under cyclic loading. Three NiTi rotary files (K3(TM), ProFile(R), and HERO 642(R)) with #30/.04 taper were evaluated. Each rotary file was divided into 2 subgroups: control (no surface defects) and experimental group (artificial surface defects). A total of six groups of each 10 were tested. The NiTi rotary files were rotated at 300rpm using the apparatus which simulated curved canal (40 degree of curvature) until they fracture. The number of cycles to fracture was calculated and the fractured surfaces were observed with a scanning electron microscope. The data were analyzed statistically. The results showed that experimental groups with surface defects had lower number of cycles to fracture than control group but there was only a statistical significance between control and experimental group in the K3(TM) (p<0.05). There was no strong correlation between the cross-sectional configuration area and fracture resistance under experimental conditions. Several of fractured files demonstrated characteristic patterns of brittle fracture consistent with the propagation of pre-existing cracks. This data indicate that surface defects of NiTi rotary files may significantly decrease fatigue life and it may be one possible factor for early fracture of NiTi rotary files in clinical practice.


Subject(s)
Fatigue , Fractures, Stress
SELECTION OF CITATIONS
SEARCH DETAIL