Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Tissue Engineering and Regenerative Medicine ; (6): 225-233, 2021.
Article in English | WPRIM | ID: wpr-896337

ABSTRACT

BACKGROUND@#Long segmental tracheal repair is challenging in regenerative medicine due to low adhesion of stem cells to tracheal scaffolds. Optimal transplantation of stem cells for tracheal defects has not been established. We evaluated the role of hyaluronic acid (HA) coating of tracheal scaffolds in mesenchymal stem cell (MSC) adhesion and tracheal regeneration in a rabbit model. @*METHODS@#A three-dimensionally printed tubular tracheal prosthesis was incubated with dopa-HA-fluorescein isothiocyanate in phosphate-buffered saline for 2 days. MSCs were incubated with an HA-coated scaffold, and their adhesion was evaluated by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay. HA coated scaffolds with or without MSC seeding were transplanted at the circumferential tracheal defect in rabbits, and survival, rigid bronchoscopy, radiologic findings, and histologic findings were compared between the two groups. @*RESULTS@#HA-coated scaffolds showed better MSC adhesion than non-coated scaffolds. The HA-coated scaffolds with MSC group showed a wider airway and greater mucosal regeneration compared to the HA-coated scaffolds without MSC group. @*CONCLUSION@#HA coating of scaffolds can promote MSC adhesion and tracheal regeneration.

2.
Tissue Engineering and Regenerative Medicine ; (6): 225-233, 2021.
Article in English | WPRIM | ID: wpr-904041

ABSTRACT

BACKGROUND@#Long segmental tracheal repair is challenging in regenerative medicine due to low adhesion of stem cells to tracheal scaffolds. Optimal transplantation of stem cells for tracheal defects has not been established. We evaluated the role of hyaluronic acid (HA) coating of tracheal scaffolds in mesenchymal stem cell (MSC) adhesion and tracheal regeneration in a rabbit model. @*METHODS@#A three-dimensionally printed tubular tracheal prosthesis was incubated with dopa-HA-fluorescein isothiocyanate in phosphate-buffered saline for 2 days. MSCs were incubated with an HA-coated scaffold, and their adhesion was evaluated by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay. HA coated scaffolds with or without MSC seeding were transplanted at the circumferential tracheal defect in rabbits, and survival, rigid bronchoscopy, radiologic findings, and histologic findings were compared between the two groups. @*RESULTS@#HA-coated scaffolds showed better MSC adhesion than non-coated scaffolds. The HA-coated scaffolds with MSC group showed a wider airway and greater mucosal regeneration compared to the HA-coated scaffolds without MSC group. @*CONCLUSION@#HA coating of scaffolds can promote MSC adhesion and tracheal regeneration.

3.
Endocrinology and Metabolism ; : 114-120, 2018.
Article in English | WPRIM | ID: wpr-713167

ABSTRACT

BACKGROUND: To compare pain, tolerability, and complications associated with fine needle aspiration (FNA) versus core needle biopsy (CNB). METHODS: FNAs were performed using 23-gauge needles and CNBs were performed using 18-gauge double-action spring-activated needles in 100 patients for each procedure. Patients were asked to record a pain score using a 10-cm visual analog scale and procedure tolerability. Complications and number of biopsies were recorded. RESULTS: The median pain scores were similar for the FNA and CNB approaches during and 20 minutes after the biopsy procedures (3.7 vs. 3.6, P=0.454; 0.9 vs. 1.1, P=0.296, respectively). The procedure was tolerable in all 100 FNA patients and in 97 CNB patients (P=0.246). The mean number of biopsies was fewer in the CNB group (1.4 vs. 1.2, P=0.002). By subgroup analysis (staff vs. non-staff), no significant difference was detected in any parameter. There were no major complications in either group, but three patients who underwent CNB had minor complications (P=0.246). CONCLUSION: FNA and CNB show no significant differences for diagnosing thyroid nodules in terms of pain, tolerability, or complications.


Subject(s)
Humans , Biopsy , Biopsy, Fine-Needle , Biopsy, Large-Core Needle , Needles , Thyroid Gland , Thyroid Nodule , Visual Analog Scale
SELECTION OF CITATIONS
SEARCH DETAIL