Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Clinical and Experimental Otorhinolaryngology ; : 66-68, 2014.
Article in English | WPRIM | ID: wpr-8122

ABSTRACT

Laser-assisted uvulopalatoplasty (LAUP) was widely performed in 1990s as a surgical therapeutic procedure to improve snoring or mild obstructive sleep apnea (OSA). However, LAUP is not currently recommended as a treatment for OSA because the evidence for its efficacy is insufficient. Little is known about alternative minimally invasive surgery in patients who refuse continuous positive airway pressure or oral appliance after failed LAUP. We present a case of successful surgical treatment of persistent snoring and mild OSA with palatal implants after LAUP. This case suggests that palatal implants may be offered as an alternative surgical procedure for selective patients with persistent or recurrent snoring or mild OSA after LAUP.


Subject(s)
Humans , Continuous Positive Airway Pressure , Palate , Sleep Apnea, Obstructive , Snoring , Minimally Invasive Surgical Procedures
2.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 201-205, 2013.
Article in Korean | WPRIM | ID: wpr-646208

ABSTRACT

BACKGROUND AND OBJECTIVES: The purpose of the study was to evaluate the changes in electrical stimulation levels, i.e. threshold (T) levels, comfortable (C) levels, dynamic range (DR), and electrode impedance values (EIVs) during the first year in cochlear implant users. SUBJECTS AND METHOD: The maps of 49 cochlear implant users (at least 1 year mapping), using the Nucleus device, were examined at the time of initial connection, and at 6 and 12 months post-initial stimulation. T levels, C levels, DR and EIVs were analyzed according to three frequency levels. RESULTS: During the first 6 months of implant use, C levels and DR increased significantly whereas T levels were stable. EIVs of current carrying electrodes decreased significantly from the connection to the 12-month visit. The changes of electrical stimulation levels did not differ among three frequency levels during the entire follow-up. CONCLUSION: During the first 6 months of implant use, C levels and DR increased significantly. Thus, an appropriate mapping in the first 6 month is critical to setup hearing capacity in implant users. The mapping should be performed under the best communication environment between the audiologist and the patient, and it makes correct setting of T levels from the initial connection period.


Subject(s)
Humans , Auditory Threshold , Cochlear Implants , Electric Impedance , Electric Stimulation , Electrodes , Hearing , Lifting , Longitudinal Studies
SELECTION OF CITATIONS
SEARCH DETAIL