Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Korean Journal of Radiology ; : 20-26, 2012.
Article in English | WPRIM | ID: wpr-28659

ABSTRACT

OBJECTIVE: To assess the performance of a high-definition CT (HDCT) for imaging small caliber coronary stents (< or = 3 mm) by comparing different scan modes of a conventional 64-row standard-definition CT (SDCT). MATERIALS AND METHODS: A cardiac phantom with twelve stents (2.5 mm and 3.0 mm in diameter) was scanned by HDCT and SDCT. The scan modes were retrospective electrocardiography (ECG)-gated helical and prospective ECG-triggered axial with tube voltages of 120 kVp and 100 kVp, respectively. The inner stent diameters (ISD) and the in-stent attenuation value (AVin-stent) and the in-vessel extra-stent attenuation value (AVin-vessel) were measured by two observers. The artificial lumen narrowing (ALN = [ISD - ISDmeasured]/ISD) and artificial attenuation increase between in-stent and in-vessel (AAI = AVin-stent - AVin-vessel) were calculated. All data was analyzed by intraclass correlation and ANOVA-test. RESULTS: The correlation coefficient of ISD, AVin-vessel and AVin-stent between the two observers was good. The ALNs of HDCT were statistically lower than that of SDCT (30 +/- 5.7% versus 35 +/- 5.4%, p < 0.05). HDCT had statistically lower AAI values than SDCT (15.7 +/- 81.4 HU versus 71.4 +/- 90.5 HU, p < 0.05). The prospective axial dataset demonstrated smaller ALN than the retrospective helical dataset on both HDCT and SDCT (p < 0.05). Additionally, there were no differences in ALN between the 120 kVp and 100 kVp tube voltages on HDCT (p = 0.05). CONCLUSION: High-definition CT helps improve measurement accuracy for imaging coronary stents compared to SDCT. HDCT with 100 kVp and the prospective ECG-triggered axial technique, with a lower radiation dose than 120 kVp application, may be advantageous in evaluating coronary stents with smaller calibers (< or = 3 mm).


Subject(s)
Humans , Analysis of Variance , Cardiac-Gated Imaging Techniques/methods , Coronary Disease/diagnostic imaging , Phantoms, Imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Stents , Tomography, Spiral Computed/methods
2.
Chinese Journal of Clinical Psychology ; (6)2000.
Article in Chinese | WPRIM | ID: wpr-536311

ABSTRACT

Objective: To compare the H.R neuropsychological functions of urban and rural children and to elucidate possible affecting factors. Methods:57 urban children and 54 rural children between 6.5~7.5 ages were assessed on the Halstead-Reitan Neuropsychological Battery. Results:①The scores of Category, Touch Operating, and Proceeding subtests in H.R.B of urban children were significantly higher than those of rural children.②There were significant differences in parenting behaviors between the parents of urban children and rural children.③There were significant correlations between parenting behaviors and H.R.B performance. Conclusion: Parenting behavior could be an influential factor in the development of neuropsychological functioning in children.

SELECTION OF CITATIONS
SEARCH DETAIL