Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 343-350, 2023.
Article in Chinese | WPRIM | ID: wpr-993095

ABSTRACT

Objective:To investigate the necessity and feasibility of the virtual simulation teaching experiment software of the bronchoscopy intelligent navigation-based fiducial marker implantation technology in the clinical application of radiotherapy.Methods:This study developed a 3D virtual operation and interactive system using the Unity3D engine, tools including 3Dmax and Maya, and the SQL database. The scenes in the system were produced using the currently popular next-generation production process. Targeting the priorities and difficulties in the implantation of fiducial markers, the system developed in this study allowed for simulated demonstration and training based on 12 steps and 10 knowledge points. Internal tests and remote evaluation tests were adopted in this system to obtain the test result of each subject. Then, the application value of the system was analyzed based on the test result.Results:As of May 1, 2022, the system had received 2 409 views and 425 test participants, with an test completion rate of 100% and an experiment pass rate of 96.5%. Moreover, this system won unanimous praise from 167 users, primarily including the students majoring in multilevel medical imaging technology and medical imaging science from the Fujian Medical University, as well as the radiotherapy-related staff of this university.Conclusions:The virtual simulation teaching experiment software of the bronchoscopy intelligent navigation-based fiducial marker implantation technology can be applied to the teaching of students and the training of related professionals.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 865-870, 2022.
Article in Chinese | WPRIM | ID: wpr-956873

ABSTRACT

Objective:To explore the feasibility of recoverable fiducial marker implantation guided using the intelligent navigation bronchoscopy technology in the Cyberknife Synchrony-based respiratory tracking.Methods:CT scans of an inflatable pig lung after anti-rot processing were obtained. Then, eight simulated tumor lesion sites were designed in the left and right lung lobes using intelligent navigation software, with four classified as the sputum bronchial environment group and four classified as the wet bronchial environment group. Based on the implantation principle of Cyberknife fiducial markers, 32 recoverable fiducial markers were implanted around various simulated tumor lesions via bronchus under intelligent guidance. Then, the end-expiratory state of the pig lung was simulated, the pig lung was scanned again to obtain CT images of the implanted recoverable fiducial markers, and the number of successfully implanted fiducial markers was recorded. Eight deliverable Synchrony treatment protocols were designed using the Cyberknife planning system (Multiplan v4.6), and then the pig lung with simulated respiratory movements was exposed to radiation. After radiation, the implanted recoverable fiducial markers were retrieved using the bronchoscopy technique, and the number of successfully retrieved fiducial markers was recorded. Moreover, the translational errors, rotational errors, and rigid body errors were extracted from the Cyberknife log file and analyzed.Results:No recoverable fiducial markers slipped or fell during the experiment. Thirty-two recoverable fiducial markers were successfully implanted and recovered under the guidance of intelligent navigation bronchoscopy, with implantation and recovery success rates of both 100%. Moreover, the tracking rate and rigid body errors of the fiducial markers were 100% and less than 5 mm, respectively. The data from the Cyberknife log file indicated that there was no significant difference between the sputum bronchial environment group and the wet bronchial environment group in the translational errors in the left-right direction, the rotational errors in the roll direction, and the rotational errors in the pitch direction ( P>0.05). Compared to the wet bronchial environment group, the sputum bronchial environment group had slightly higher translational errors in front-back ( Z=-3.57, P<0.01) and cranio-caudal ( Z=-2.53, P<0.05) directions, lower rotational errors along the yaw axis ( Z = -3.88, P < 0.01), and lower rigid body error ( Z=-3.32, P<0.01), and the differences were all statistically significant. Conclusions:The recoverable fiducial marker implantation guided using the intelligent navigation bronchoscopy technology is feasible. Recoverable fiducial markers are stable in the bronchus of the phantom, and the Cyberknife tracking precision can meet clinical requirements. Therefore, the recoverable fiducial marker implantation guided using the intelligent navigation bronchoscopy technology has promising prospects in clinical and teaching applications.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 630-634, 2017.
Article in Chinese | WPRIM | ID: wpr-611153

ABSTRACT

Objective To investigate the feasibility of low-c oncentration iso_osmolar contrast agent together with low tube voltage and iterative reconstruction algorithm in rabbit liver computed tonography (CT) perfusion imaging.Methods A total of 15 bealthy New Zealand rabbits were scanned twice of liver CT perfusion scans each with 24 hours interval.The first scan (routine group) was acquired at 100 kV and 100 mAs with ultravist (370 mg/ml),while the second (double low group) was acquired at 80 kV and 100 mAs with iodixanol (270 mg/ml) at 24 hours after the first scan.The obtained images were reconstructed with filtered back projection (FBP) and adaptive iterative dose reduction (AIDR-3D)algorithms in the controlled and experimental groups,respectively.The perfusion parameters including hepatic artery perfusion(HAP),portal vein perfasion(PVP),hepatic perfusion index(HPI),and total liver perfusion(TLP) and image quality as image quality score,average CT value of abdomen aorta,signalto-noise ratio(SNR),carrier-to-noise ratio(CNR),and figure of merit(FOM) were compared used pair ttest or Mann-Whitney U-test between the two groups wherever appropriate.The effective radiation dose and iodine intake were also recorded and compared.Results The image quality and perfusion parameters had no significantly different between the two groups except for FOM.The effective radiation dose and iodine intake were 38.79% and 27.03% lower in the double low group.Conclusions Low concentration iso _osmolar contrast agent (iodixanol,270 mg/ml) together with low tube voltage (80 kV) helps to reduce radiation dose and iodine intake without compromising perfusion parameters and image quality in liver CT perfusion imaging.

SELECTION OF CITATIONS
SEARCH DETAIL