Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Article | IMSEAR | ID: sea-215131

ABSTRACT

Measurement of blood pressure accurately is imperative in the diagnosis and monitoring of a wide range of clinical conditions. The mercury sphygmomanometer discovered more than 100 years ago, has since been used as the gold standard to record blood pressure. Using the mercury sphygmomanometer requires adequate training and practice, whereas the automated devices are convenient and easier to use. We wanted to compare the readings taken by the manual mercury and the digital sphygmomanometer and determine the variations in the readings if any. MethodsThis cross-sectional study was done in 148 apparently healthy medical students (males n=58, females n=90) (Fig. 1). Written informed consent was taken and the procedure was carried out. Questionnaires were provided to obtain demographic data from students. Blood pressure was recorded in the dominant arm using Pulse Wave 300 NISCO mercury sphygmomanometer, and OMRON HEM-7130 digital sphygmomanometer in the sitting, standing and recumbent posture. Three readings were recorded in each position with an interval of 2 mins., between each recording. The mean of the systolic and diastolic blood pressured was compared between the mercury and digital sphygmomanometer for variations if any. Data was analyzed using IBM SPSS version 22. P value of ≤ 0.05 was considered significant. ResultsIn our study out of the 148 participants 58 were males and 90 were females. The overall mean systolic blood pressure recorded using the mercury sphygmomanometer was found to be 107.59 ± 11.62 mmHg; mean diastolic blood pressure was found to be 68.83 ± 8.91 mmHg; overall mean systolic blood pressure recorded using the digital sphygmomanometer was found to be 107.72 ± 13.36 mmHg and overall mean diastolic blood pressure was found to be 71.4 ± 9.62 mmHg. ConclusionsIn our study no statistically significant difference was found between the BP measurements recorded using the mercury and digital sphygmomanometer (Table. 1, 2). Mercury sphygmomanometer still remains the gold standard in recording blood pressure, and those who are unskilled in recording BP using the standard method could utilize the digital device as it is easier and more convenient.

2.
RPG rev. pos-grad ; 10(3): 211-216, jul.-set. 2003. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-391749

ABSTRACT

O objetivo desta pesquisa foi avaliar, por meio da análise fotoelástica, a concentração de tensões ao redor de raízes dentais e rebordos alveolares, considerando-se diferentes sistemas de retenção utilizados na confecção de sobredentaduras (Cúpula, O'Ring, ERA, Magneto). Foram aplicadas cargas (11 kg, 16 kg e 20 kg) verticais e inclinadas em: canino, segundo pré-molar e primeiro molar inferiores. Os resultados permitiram-nos concluir que: 1) as menores tensões foram observadas com o modelo cúpula; 2) as maiores tensões foram observadas com os modelos O'Ring e ERA; 3) os sistemas O'Ring, ERA e magneto apresentaram tensões cervicais; 4) em todas as situações, as tensões aumentaram quando as cargas foram inclinadas


Subject(s)
Denture, Complete , In Vitro Techniques , Tooth Root , Models, Dental , Dental Prosthesis Retention , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL