Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Arq. bras. cardiol ; 103(3): 231-237, 09/2014. tab, graf
Article in English | LILACS | ID: lil-723827

ABSTRACT

Background: Heart failure with preserved ejection fraction (HFPEF) is the most common form of heart failure (HF), its diagnosis being a challenge to the outpatient clinic practice. Objective: To describe and compare two strategies derived from algorithms of the European Society of Cardiology Diastology Guidelines for the diagnosis of HFPEF. Methods: Cross-sectional study with 166 consecutive ambulatory patients (67.9±11.7 years; 72% of women). The strategies to confirm HFPEF were established according to the European Society of Cardiology Diastology Guidelines criteria. In strategy 1 (S1), tissue Doppler echocardiography (TDE) and electrocardiography (ECG) were used; in strategy 2 (S2), B-type natriuretic peptide (BNP) measurement was included. Results: In S1, patients were divided into groups based on the E/E'ratio as follows: GI, E/E'> 15 (n = 16; 9%); GII, E/E'8 to 15 (n = 79; 48%); and GIII, E/E'< 8 (n = 71; 43%). HFPEF was confirmed in GI and excluded in GIII. In GII, TDE [left atrial volume index (LAVI) ≥ 40 mL/m2; left ventricular mass index LVMI) > 122 for women and > 149 g/m2 for men] and ECG (atrial fibrillation) parameters were assessed, confirming HFPEF in 33 more patients, adding up to 49 (29%). In S2, patients were divided into three groups based on BNP levels. GI (BNP > 200 pg/mL) consisted of 12 patients, HFPEF being confirmed in all of them. GII (BNP ranging from 100 to 200 pg/mL) consisted of 20 patients with LAVI > 29 mL/m2, or LVMI ≥ 96 g/m2 for women or ≥ 116 g/m2 for men, or E/E'≥ 8 or atrial fibrillation on ECG, and the diagnosis of HFPEF was confirmed in 15. GIII (BNP < 100 pg/mL) consisted of 134 patients, 26 of whom had the diagnosis of HFPEF confirmed when GII parameters were used. Measuring BNP levels in S2 identified 4 more patients (8%) with HFPEF as compared with those identified in S1. Conclusion: The association of BNP measurement and TDE data ...


Fundamento: A insuficiência cardíaca com fração de ejeção normal é a forma mais comum de insuficiência cardíaca e seu diagnóstico é um desafio na prática ambulatorial. Objetivo: Descrever e comparar duas estratégias, derivadas dos algoritmos do Consenso Europeu de Diastologia para diagnóstico de insuficiência cardíaca com fração de ejeção normal. Métodos: Estudo transversal com 166 pacientes (67,9 ± 11,7 anos, 72% mulheres) ambulatoriais consecutivos. As estratégias para confirmar insuficiência cardíaca com fração de ejeção normal foram estabelecidas de acordo com os critérios do Consenso Europeu de Diastologia. Na estratégia 1, utilizamos dados do eco Doppler tecidual e eletrocardiograma; na estratégia 2, incluímos o peptídeo natriurético tipo B. Resultados: Na primeira estratégia, os pacientes foram classificados em grupos, de acordo com a relação E/E': GI se E/E' > 15 (n = 16; 9%); GII se E/E' 8 a 15 (n = 79; 48%); e GIII se E/E' < 8 (n = 71; 43%). Insuficiência cardíaca com fração de ejeção normal foi confirmada no GI e excluída no GIII. No GII, parâmetros do eco Doppler tecidual (volume do átrio esquerdo indexado ≥ 40 mL/m2; massa do ventrículo esquerdo indexado > 122 para mulheres e > 149 g/m2 para homens) e do eletrocardiograma (fibrilação atrial) foram analisados, confirmando insuficiência cardíaca com fração de ejeção normal em mais 33 pacientes, totalizando 49 (29%). Na estratégia 2, utilizando o peptídeo natriurético tipo B, os pacientes foram divididos em três grupos. O GI (peptídeo natriurético tipo B > 200 pg/mL) foi formado por 12 pacientes e a insuficiência cardíaca com fração ...


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Heart Failure/diagnosis , Heart Failure/physiopathology , Heart Ventricles/physiopathology , Stroke Volume/physiology , Algorithms , Ambulatory Care Facilities , Atrial Fibrillation/physiopathology , Atrial Fibrillation , Cross-Sectional Studies , Echocardiography, Doppler , Electrocardiography , Guidelines as Topic , Natriuretic Peptide, Brain/blood , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , Statistics, Nonparametric
2.
Rev. bras. cardiol. (Impr.) ; 26(4): 253-258, jul.-ago. 2013. tab
Article in Portuguese | LILACS | ID: lil-702190

ABSTRACT

Fundamentos: Estudos têm demonstrado forte associação entre déficit de vitamina D (VitD) e risco de doença cardiovascular. Níveis reduzidos de VitD apresentam elevada prevalência, e são considerados fator de mau prognóstico na insuficiência cardíaca (IC). Objetivo: Avaliar a deficiência de VitD em pacientes com suspeita de IC e fração de ejeção normal e sua correlação com marcadores de função diastólica e sistólica. Métodos: Estudo transversal com 85 pacientes ambulatoriais (idade 70,8±11,5 anos, sexo feminino 72 % - Rio de Janeiro, latitude -22° Sul) com suspeita de IC e que apresentavam fração FEVE normal. Os pacientes foram submetidos à dosagem de vitamina D 25-hidroxi (25(OH)D) e BNP e realização de ecocardiograma, Doppler tecidual e eletrocardiograma para investigação de ICFEN, de acordo com os critérios da Sociedade Europeia de Cardiologia. Resultados: ICFEN foi confirmada em 32 pacientes (38 %) que tinham valores maiores de BNP (135,1 mediana 109 pg/mL vs. 23,4 mediana 16,4 pg/mL; p<0,0001) e dos índices de disfunção diastólica (volume AE-I 44,2±8,9 mL/m2 vs. 29,3±7,4 mL/m2; relação E/E’ 14,5±6,6 vs. 7,5±2,1; p<0,0001). Valores de VitD foram menores no grupo com ICFEN, com significado estatístico (34,9±14,9 mcg/L vs. 45,0±17,6 mcg/L; p=0,008). Regressão binária logística mostrou idade (p=0,001) e VitD (p=0,036) como fatores independentes significativos para ICFEN. Observou-se correlação negativa entre a relação E/E’ e valores de VitD (r=-0,300 p=0,005). Conclusão: Pacientes com ICFEN apresentavam menores níveis séricos de VitD e quase a metade apresentava deficiência de VitD. Observou-se correlação negativa entre VitD e relação E/E’ marcador da pressão de enchimento do VE.


Background: Studies have shown a strong association between vitamin D (VitD) deficiency and the risk of cardiovascular disease. Widely prevalent, VitD deficiency is considered as a poor prognosis factor for heart failure (HF).Objective: To assess VitD deficiency among patients with heart failure with normal ejection fraction (HFNEF) and correlations with systolic and diastolic function markers. Methods: A cross-section study with 85 outpatients (age 70.8±11.5 years, female 72 %, Rio de Janeiro, latitude -22°S) with suspected HF and normal EF, dosed with 25-hydroxy vitamin D (25(OH)D) and BNP measurements, with echocardiograms, tissue Doppler and electrocardiograms for investigating HFNEF, in compliance with the criteria established by the European Society of Cardiology. Results: HFNEF was confirmed in 32 patients (38 %) with higher BNP values (135.1 median 109 pg/mL vs. 23.4 median 16.4 pg/mL; p<0.0001) and diastolic dysfunction rates (volume AE-I 44.2±8.9 mL/m2 vs. 29.3±7.4 mL/m2, E/E’ 14.5±6.6 vs. 7.5±2.1; p<0.0001). The VitD values were lower in the HFNEF group, with statistical significance (34.9±14.9 mcg/L vs. 45.0±17.6 mcg/L; p=0.008). A binary logistic regression revealed age (p=0.001) and vitamin D (p=0.036) as independent factors significant for HFNEF. A negative correlation was noted between the E/E` ratio and the VitD values (r=-0.300 p=0.005). Conclusion: HFNEF patients had lower serum VitD levels and almost half were VitD deficient. A negative correlation was noted between VitD and the E/E’ ratio, an LV filling pressure marker.


Subject(s)
Humans , Male , Female , Middle Aged , Diastole/physiology , Cardiovascular Diseases/complications , Heart Failure/complications , Vitamin D/analysis , Echocardiography, Doppler/methods , Echocardiography, Doppler , Prevalence
3.
Arq. bras. cardiol ; 98(2): 175-181, fev. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-614509

ABSTRACT

FUNDAMENTO: O modelo fisiopatológico da insuficiência cardíaca com fração de ejeção normal (ICFEN) está centrado na presença de disfunção diastólica, o que ocasiona mudanças estruturais e funcionais no átrio esquerdo (AE). A medida do tamanho do AE pode ser utilizada como um marcador da presença de ICFEN, sendo um indicador da elevação crônica da pressão de enchimento do VE, cuja mensuração é de fácil obtenção. OBJETIVO: Estimar a acurácia da medida do tamanho do AE, utilizando os valores indexados do diâmetro e do volume do AE para o diagnóstico de ICFEN em pacientes ambulatoriais. MÉTODOS: Estudamos 142 pacientes (67,3 ± 11,4 anos, 75 por cento de mulheres) com suspeita de IC, os quais foram divididos em dois grupos: com ICFEN (n = 35) e sem ICFEN (n = 107). RESULTADOS: A função diastólica, avaliada pelo ecodopplercardiograma, mostrou diferença significativa entre os dois grupos em relação aos parâmetros que avaliaram o relaxamento ventricular (E' 6,9 ± 2,0 cm/s vs. 9,3 ± 2,5 cm/s - p < 0,0001) e a pressão de enchimento do VE (relação E/E' 15,2 ± 6,4 vs. 7,6 ± 2,2 - p < 0,0001). O ponto de coorte do volume do AE indexado (VAE-I) de 35 mL/m² foi o que melhor se correlacionou com o diagnóstico de ICFEN, demonstrando sensibilidade de 83 por cento, especificidade de 83 por cento e acurácia de 83 por cento. Já o ponto de coorte do diâmetro ântero-posterior do AE indexado (DAE-I) de 2,4 cm/m² apresentava sensibilidade de 71 por cento, especificidade de 66 por cento e acurácia de 67 por cento. CONCLUSÃO: Para o diagnóstico de ICFEN em pacientes ambulatoriais, o VAE-I é o método mais acurado em comparação ao DAE-I. Na avaliação ecocardiográfica, a medida do tamanho do AE deveria ser substituída pela medida indexada do volume. (Arq Bras Cardiol. 2011; [online].ahead print, PP.0-0).


BACKGROUND: The pathophysiological model of heart failure (HF) with preserved ejection fraction (HFPEF) focuses on the presence of diastolic dysfunction, which causes left atrial (LA) structural and functional changes. The LA size, an indicator of the chronic elevation of the left ventricular (LV) filling pressure, can be used as a marker of the presence of HFPEF, and it is easily obtained. OBJECTIVE: To estimate the accuracy of measuring the LA size by using indexed LA volume and diameter (ILAV and ILAD, respectively) for diagnosing HFPEF in ambulatory patients. METHODS: This study assessed 142 patients (mean age, 67.3 ± 11.4 years; 75 percent of the female sex) suspected of having HF, divided into two groups: with HFPEF (n = 35) and without HFPEF (n = 107). RESULTS: The diastolic function, assessed by use of Doppler echocardiography, showed a significant difference between the groups regarding the parameters assessing ventricular relaxation (E': 6.9 ± 2.0 cm/s vs. 9.3 ± 2.5 cm/s; p < 0.0001) and LV filling pressure (E/E' ratio: 15.2 ± 6.4 vs. 7.6 ± 2.2; p < 0.0001). The ILAV cutoff point of 35 mL/m2 best correlated with the diagnosis of HFPEF, showing sensitivity, specificity, and accuracy of 83 percent. The ILAD cutoff point of 2.4 cm/m2 showed sensitivity of 71 percent, specificity of 66 percent, and accuracy of 67 percent. CONCLUSION: For diagnosing HFPEF in ambulatory patients, the ILAV proved to be a more accurate parameter than ILAD. On echocardiographic assessment, ILAV, rather than ILAD, should be routinely measured. (Arq Bras Cardiol. 2011; [online].ahead print, PP.0-0).


Subject(s)
Aged , Female , Humans , Male , Heart Failure, Diastolic , Stroke Volume/physiology , Ventricular Dysfunction, Left , Epidemiologic Methods , Echocardiography, Doppler/adverse effects , Echocardiography, Doppler/methods , Heart Atria/pathology , Heart Atria , Heart Failure, Diastolic/physiopathology , Organ Size , Ventricular Dysfunction, Left/physiopathology
4.
Rev. bras. cardiol. (Impr.) ; 24(5): 320-325, set.-out. 2011. tab, graf
Article in Portuguese | LILACS | ID: lil-608357

ABSTRACT

Fundamentos: A insuficiência cardíaca (IC) representa um importante problema de saúde pública, tem custoelevado e crescente prevalência nos países desenvolvidos e em desenvolvimento. Dados do Sistema Único de Saúde, que responde por 80% do atendimento médico da população brasileira, mostram que as doenças cardiovasculares são a terceira causade internação, sendo a IC a causa mais frequente entre as doenças cardiovasculares após os 60 anos. Pesquisas sobre epidemiologia envolvendo prevalência da ICsão escassos no Brasil principalmente na atenção primária. Objetivo: Estimar a prevalência da insuficiência cardíaca na atenção primária. Métodos: Estudo observacional, transversal, envolvendo 632 indivíduos selecionados de modoaleatório, com idade ≥45 anos, assistidos pelo Programa Médico de família de Niterói, RJ. O diagnóstico de IC será confirmado ou excluídoutilizando-se: exame clínico, eletrocardiograma, ecocardiograma e dosagem de BNP. Todos os pacientesserão classificados em estágios que avaliam a progressão fisiopatológica da IC, de acordo com o estabelecido na III Diretriz Brasileira de IC crônica.Conclusão: O estudo pretende estabelecer a prevalência de IC em uma comunidade urbana, o que irá ajudarno planejamento da política de saúde para o cuidado da IC.


Subject(s)
Humans , Male , Female , Middle Aged , Family Health , Heart Failure/epidemiology , Public Health/statistics & numerical data , Unified Health System/statistics & numerical data , Brazil , Cross-Sectional Studies , Epidemiologic Studies , Prevalence
5.
Rev. bras. cardiol. (Impr.) ; 24(3): 192-195, maio-jun. 2011. ilus
Article in Portuguese | LILACS | ID: lil-599025

ABSTRACT

Paciente ambulatorial, sexo feminino, 58 anos de idade, com queixa de dor atípica em hemitórax direito. As bulhas cardíacas eram ouvidas no precórdio direito, normais. A radiografia torácica evidenciou dextrocardia em situs inversus. No ECG as ondas P eram negativas em D1 e a VL, enquanto nas derivações precordiais havia regressão do QRS de V1 a V6. Após a inversão dos eletrodos dos braços e do reposicionamento dos eletrodos no hemitórax direito, o ECG mostrava “normalização”. O vetor cardiograma evidenciava inversão das alças da ativação atrial e ventricular confirmando o diagnóstico eletrocardiográfico.


A 58-year-old female ambulatory patient reported atypical right chest pain. Heart sounds were heard in theright hemithorax, with no anormalies. The chest radiograph showed dextrocardia with situs inversus. Onthe ECG, the P waves were negative in D1 and aVL while in the thoracic leads the QRS decreased from V1 to V6. After reversing the arm electrodes and repositioning the chest leads on the right side, the electrocardiogram became “normal”. The vectorcardiogram showed inversion of the atrial and ventricular activation loops, confirming the electrocardiographic diagnosis.


Subject(s)
Humans , Female , Middle Aged , Heart Defects, Congenital , Dextrocardia , Situs Inversus , Electrocardiography/methods , Electrocardiography
6.
Arq. bras. cardiol ; 94(6): 799-805, jun. 2010. ilus, graf, tab
Article in English, Portuguese | LILACS | ID: lil-550696

ABSTRACT

FUNDAMENTO: A insuficiência cardíaca com fração de ejeção normal (ICFEN) é hoje o modelo mais prevalente de IC em diferentes estudos epidemiológicos, e anormalidades na função sistólica de grau leve (subclínica) têm sido observadas nesses pacientes quando a contratilidade do ventrículo esquerdo (VE) é avaliada no eixo longitudinal (S') pelo ecocardiograma Doppler tecidual (EDT), mesmo na presença de fração de ejeção do VE normal. OBJETIVO: Avaliar se pacientes com diagnóstico de ICFEN, de acordo com os novos critérios da Sociedade Europeia de Cardiologia, apresentam alterações da função sistólica constatada pela medida de S' quando comparados com os pacientes em que a ICFEN não foi confirmada. MÉTODOS: Cento e dezoito pacientes com sinais ou sintomas de IC foram submetidos a dosagem de BNP e ao EDT com medidas da velocidade do eixo longitudinal na sístole (S') e diástole (E') e medidas do fluxo transmitral durante a diástole (E,A). RESULTADOS: ICFEN foi confirmada em 38 pacientes (32,2 por cento). O pico da velocidade miocárdica durante a sístole (S') e a velocidade miocárdica no inicio da diástole (E') estavam significativamente diminuídas em pacientes com ICFEN em relação aos pacientes em que a ICFEN foi excluída (7,8 ± 2,3 cm/s vs 9,4 ± 2,5 cm/s p=0,002 - 7,7 ± 2,6 cm/s vs 9,4 ± 2,5 cm/s-p=0,001). Valores médios de BNP foram mais elevados em pacientes com ICFEN (140,5 ± 122,4 pg/ml vs 23,1 ± 25,0 pg/ml p< 0,0001). S' se correlacionou de modo significativo com E' (r=0,457 - p< 0,0001) mostrando uma forte ligação entre contração e relaxamento ventricular. CONCLUSÃO: Nossos achados mostram redução da função sistólica, quando avaliada pelo S', na ICFEN, existindo correlação linear entre o grau de disfunção sistólica (S') e diastólica (E/E'e E').


BACKGROUND: Heart failure with normal ejection fraction (HFNEF) is now the most prevailing model of HF in different epidemiological studies, and abnormalities in mild systolic function (subclinical) have been observed in those patients when the left ventricular contractility (LV) is evaluated in the longitudinal axis (S') by tissue Doppler echocardiography (TDE), even in normal LV ejection fraction. OBJECTIVE: To evaluate whether patients with HFNEF, according to the new criteria set out by the European Society of Cardiology, present changes in systolic function detected by S' measurement when compared with patients whose HFNEF has not been confirmed. METHODS: One hundred eighteen patients with signs or symptoms of HF underwent BNP measurement and TDE with measurements of longitudinal axis velocity during systole (S') and diastole (E') and measures of transmitral flow during diastole (E, A). RESULTS: HFNEF was confirmed in 38 patients (32.2 percent). Peak myocardial velocity during systole (S') and myocardial velocity in early diastole (E') were significantly reduced in patients with HFNEF compared to patients whose HFNEF was deleted (7.8 ± 2.3 cm/s vs 9.4 ± 2.5 cm/s p=0.002 - 7.7 ± 2.6 cm/s vs 9.4 ± 2.5 cm/s - p=0.001). Mean BNP values were higher in patients with HFNEF (140.5 ± 122.4 pg/ml vs 23.1 ± 25.0 pg/ml p <0.0001). S' correlated significantly with E' (r=0.457 - p<0.0001) revealing a strong link between ventricular contraction and relaxation. CONCLUSION: Our findings show a reduction of systolic function, as measured by S 'in HFNEF and a linear correlation between the systolic (E / E 'and E') and diastolic dysfunction degree.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Heart Failure/physiopathology , Stroke Volume/physiology , Systole/physiology , Ventricular Dysfunction, Left , Diastole/physiology , Echocardiography, Doppler , Heart Failure , Prospective Studies , Sex Distribution , Time Factors , Ventricular Dysfunction, Left/physiopathology
7.
Rev. SOCERJ ; 22(5): 294-302, set.-out. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-540219

ABSTRACT

Atualmente mais da metade dos pacientes com insuficiência cardíaca (IC) tem fração de ejeção do ventrículo esquerdo normal; são geralmente idosos, predominantemente mulheres, e com alta incidência de comorbidades. Esses pacientes são caracterizados como portadores de IC com FEVE normal (ICFEN). As comorbidades podem contribuir de forma isolada ou sinérgica nas alterações das funções diastólica, vascular e renal com papel importante no desenvolvimento dos sinais e sintomas de IC. Objetivo: Identificar a prevalência das principais comorbidades presentes em pacientes com ICFEN. Métodos: Estudo transversal prospectivo, envolvendo 118 pacientes (idade média 68,8 +/- 12,0 anos) em que foram avaliadas as principais comorbidades: obesidade, síndrome metabólica, diabetes, hipertensão arterial, doença renal, anemia, doença coronariana, hipotiroidismo e fibrilação atrial. Pacientes foram estratificados em dois grupos: com ICFEN e sem ICFEN, de acordo...


Subject(s)
Humans , Female , Aged , Hypertension/etiology , Heart Failure/complications , Comorbidity , Prevalence , Radiography
8.
Rev. SOCERJ ; 21(4): 232-238, jul.-ago. 2008. tab
Article in Portuguese | LILACS | ID: lil-500179

ABSTRACT

Fundamentos: A aplicação das diretrizes da Sociedade Européia de Cardiologia (SEC) na prática médica diária poderá aumentar a acurácia diagnóstica da insuficiência cardíaca com fração de ejeção normal (ICFEN). A confirmação ou exclusão diagnóstica da ICFEN poderá trazer como consequência a possibilidade de intervenção terapêutica adequada ou o redirecionamento para a busca de outras etiologias. O correto diagnóstico poderá levar à redução da morbimortalidade provocada pela ICFEN. Objetivo: Este estudo foi desenhado para avaliar a implantação da diretriz do SEC com a utilização do ecoDoppler com imagem e de peptídeo natriurético tipo-B (BNP) no diagnóstico ou na exclusão da ICFEN. Métodos: Serão avaliados 150 pacientes de ambos os sexos, com idade maior de 18 anos, com sintomas ou sinais de insuficiência cardíaca com realização de RX de tórax, eletrocardiograma, BNP e ecoDoppler tecidual. Conclusão: Este estudo irá avaliar se o algoritmo da Diretriz da Sociedade Européia de Cardiologia poderá ser útil na prática clínica para a avaliação de pacientes ambulatoriais com sinais ou sintomas de insuficiência cardíaca.


Subject(s)
Humans , Male , Female , Adult , Echocardiography/methods , Echocardiography , Heart Failure/complications , Heart Failure/diagnosis , Radiography, Thoracic , Data Interpretation, Statistical
9.
Rev. SOCERJ ; 20(5): 376-380, set.-out. 2007. graf
Article in Portuguese | LILACS | ID: lil-485756

ABSTRACT

Homem de 115 anos, sem sintomas cardiovascvulares nem fatores de risco conhecidos, exceto a idade e o sexo masculino. Portador de déficit auditivo e catarata. Exame físico: ritmo cardíaco regular, 60bpm, sopro sistólico mitro-aórtico grau 1 mais/6 mais. Normotenso. Exames laboratoriais: hemograma mostrou anemia macrocítica; urinálise evidenciou bacteriúria; bioquímica sanguínea: fosfatase alcalina, AST, ALT, lipidograma, uréia, creatinina, glicose e PCR ultra-sensível sem alterações. Bradicardia sinusal, distúrbio da condução interatrial e atraso da condução pelo ramo direito foram encontradas no eletrovetorcardiograma. O ecocardiogramaevidenciou esclerose aórtica e regurgitação aorto-mitro-tricúspide e pulmonar de grau leve. as características deste paciente sugerem que sua excepcional liongevidade esteja relacionada com um perfil de ótimo risco cardiovascular. Este extraordinário paciente viveu aproximadamente 42.200 dias, ou um milhão de horas, ou 60 milhões de minutos. Assumindo-se uma frequência média de 70bpm, seu coração bateu 4.230.000 vezes durante a vida. Um tremendo trabalho para uma bomba biológica.


Subject(s)
Humans , Male , Aged
SELECTION OF CITATIONS
SEARCH DETAIL