Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Acta odontol. latinoam ; 34(3): 221-225, 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1383408

ABSTRACT

ABSTRACT The aim of this research was to determine compressive and shear bond strength of blocks prepared with bulk-fill and nanofill composite resin combinations. Materials used were Filtek Bulk Fill (FBF) and Z350 (both 3M-ESPE) and Surefil SDR flow (SFF) - Dentsply. To determine shear bond strength, cylindrical specimens 10 mm thick were prepared with composite consisting of thicknesses of 6 mm of one material and 4 mm of the other, in the following combinations: G1: FBF- FBF; G2: Z350-Z350, G3: FBF-Z350, G4: Z350-SFF and G5: SFFSFF. Materials were cured using a 1100 mw/cm2 light for 20 seconds for each layer. Samples were stored for 24 hours at 37 °C in distilled water and shear bond strength was determined. To assess compressive strength, cylindrical samples 4 mm diameter and 6 mm thick consisting of 4 mm + 2 mm were used in the same combinations as described above, stored in distilled water at 37 °C for 24 hours, after which compressive strength was determined. Both tests were performed with a Universal testing machine at a cross head speed of 1 mm/min. Results were analyzed with ANOVA and Tukey's test. Means and standard deviations in MPa for each group were the following: Shear bond strength: G1: 435.87 (65.86), G2: 233.6 (108.15), G3: 279.2 (22.05), G4:449.1 (109.35) and G5: 196.6 (51.16). Compressive strength: G1:160.07(4.27), G2: 149.49 (14.06), G3: 156.10 (29.99), G4: 199-30(39.28), G5: 171.23 (28.71). Evaluation with ANOVA showed no significant differences among combinations for compressive strength (p>0.05) and significant differences for bond strength (p<0.05). Tukey's test showed three homogeneous groups. Under these experimental conditions, it can be concluded that the study combinations have adequate mechanical behavior, equivalent to materials used individually. However, shear bond strength was affected by the combinations analyzed.


RESUMEN El objetivo de este trabajo fue determinar la resistencia compresiva (RC) y la resistencia adhesiva al corte (RAC) en bloques preparados con combinaciones de composites bulk-fill y nanoparticulados. Los materiales usados fueron Filtek Bulk Fill (FBF) y Z350 (ambos de 3M-ESPE) y Surefil SDR flow (SFF) - Dentsply. Para medir la RAC, se prepararon probetas cilindricas de 10 mm de espesor consistentes en 6 mm de un material y 4 mm del otro con las siguientes combinaciones: G1: FBF- FBF; G2: Z350-Z350, G3: FBF-Z350, G4: Z350-SFF y G5: SFF-SFF. Se curaron a 1100 mw/cm2 durante 20 segundos cada capa. Se conservaron 24 horas a 37 °C en agua destilada antes de determinar la RAC. Para medir la RC se prepararon probetas de 4 mm de diametro y 6 mm de espesor (4 mm + 2 mm de cada material), con las mismas combinaciones. Se conservaron en agua destilada a 37 °C durante 24 horas y se midió la RC. Ambos ensayos se realizaron con una máquina universal para ensayos mecánicos a 1 mm/min de velocidad de desplazamiento de cabezal. Los resultados se evaluaron con ANOVA y prueba de Tukey. Las medias y desviaciones estándar (MPa) para cada grupo fueron: RAC: G1: 435.87 (65.86), G2: 233.6 (108.15), G3: 279.2 (22.05), G4:449.1 (109.35) y G5: 196.6 (51.16). RC: G1:160.07(4.27), G2: 149.49 (14.06), G3: 156.10 (29.99), G4: 199-30(39.28), G5: 171.23 (28.71). ANOVA no mostró diferencias estadísticamente significativas para RC (p>0.05) y diferencias significativas para RAC (p<0.05). La prueba de Tukey mostró tres grupos homogéneos. En las condiciones experimentales de este trabajo puede concluirse que las combinaciones evaluadas tienen un comportamiento mecánico adecuado equivalente al de los materiales individuales. Sin embargo, la adhesión entre materiales se vio afectada por las combinaciones realizadas.

2.
Acta odontol. latinoam ; 28(3): 258-262, 2015. tab, ilus
Article in English | LILACS | ID: lil-781827

ABSTRACT

El objetivo de este estudio fue evaluar la estabilidad dimensional lineal de diferentes hidrocoloides irreversibles enfunción del tiempo. Se confeccionó una matriz metálica con sus correspondientes cubetas individuales realizadas con láminas termoplásticas (Sabilex, de 0.125 mm de espesor). Sele realizaron perforaciones para la retención del material. Se tomaron cinco impresiones con cada material a esta matriz, utilizando Kromopan 100 (LASCOD) [AlKr], que presentauna estabilidad dimensional de 100 horas, y Phase Plus (ZHERMACK) [AlPh], que tiene una estabilidad dimensional de 48 horas. Luego se tomaron fotografías estandarizadas adiferentes intervalos de tiempo (0, 15, 30, 45, 60, 120 minutos; 12, 24 y 96 horas), usando un dispositivo ad-hoc. Las imágenes se analizaron con software de procesamiento de imágenes(UTHSCSA Image Tool) realizando la medición de la distancia entre las intersecciones de surcos previamente realizados en la porción superior de la matriz. Los resultados obtenidos fueronanalizados mediante Análisis de Varianza para mediciones repetidas. Se detallan los datos iniciales y finales obtenidos (media y DS): AlKr: 16,44 (0,22) y 16,34 (0,11), AlPh: 16,40(0,06) y 16,18 (0,06). El análisis estadístico ha mostrado el efecto significativo para las variables material y tiempo. Bajo las condiciones de este estudio podemos concluir que tiempoafectaría significativamente la estabilidad dimensional lineal de los hidrocoloides irreversibles...


Subject(s)
Humans , Alginates/chemistry , Colloids/chemistry , Dimensional Measurement Accuracy , Dental Impression Materials/classification , Chemical Phenomena , Analysis of Variance , Materials Testing , Data Interpretation, Statistical , Time Factors
3.
Acta odontol. latinoam ; 24(3): 289-294, 2011. ilus
Article in English | LILACS | ID: lil-668281

ABSTRACT

El objetivo del trabajo fue evaluar la estabilidad dimensional lineal de diferentes elastómeros para impresión. Se confeccionó una matriz metálica con sus correspondientes cubetas individuales realizadas con láminas termoplásticas (Marca Sabilex, de 0.125 mm de espesor). Se tomaron tres impresiones con cada material a estamatriz. Se utilizaron tres siliconas por adición: Examix-GC- (AdEx), Aquasil-Dentsply-(AdAq), y Panasil –Kettenbach-(AdPa); y tres siliconas por condensación: Densell-Dental Medrano-(CoDe), Speedex-Coltene-(CoSp), y Lastic-Kettenbach-(CoLa). Se realizaron todas las impresiones utilizando dos consistencias: pesada y liviana, con la técnica de un solo tiempo. Luego se tomaron fotografías estandarizadas a diferentes intervalos de tiempo (0, 15,30, 60, 120 minutos; 24 horas; 7 días y 14 días), con una cámara fotográfica digital, utilizando un dispositivo ad-hoc. Las imágenes se analizaron con software de procesamiento de imágenes (Image Tool) realizando la medición de la distancia entre las interseccionesde surcos previamente realizados en la porción superior de la matriz. Los resultados obtenidos fueron analizados mediante Análisis de varianza para mediciones repetidas. La media y el DSinicial y final para todos los materiales fue: AdEx: 1,32 (0,01) y 1,31 (0,00); AdAq: 1,32 (0,00) y 1,32 (0,00); AdPa: 1,327 (0,006) y 1,31 (0,00); CoDe: 1,32 (0,00) y 1,32 (0,01); CoSp: 1,327 (0,006) y 1,31 (0,00); CoLa: 1,327 (0,006) y 1,303 (0,006). La evaluaciónestadística mostró el efecto significativo de las variables material y tiempo. Conclusión: Bajo las condiciones de este estudio podemos concluir que el tiempo afectaría significativamente la estabilidad dimensional lineal de elastómeros para impresiones.


Subject(s)
Elastomers/chemistry , Dental Impression Materials/classification , Chemical Phenomena , Dental Impression Technique , Data Interpretation, Statistical , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL