Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Ciênc. rural ; 43(10): 1838-1842, Oct. 2013. ilus
Article in English | LILACS | ID: lil-686024

ABSTRACT

This research presents a noninvasive method for the acquisition of brain electrical signal in rat. Was used an electroencephalography (EEG) system developed for bovine and adapted to rats. The bipolar electrode system (needle electrodes) was glued on the surface of the head of the animal without surgical procedures and the other electrode was glued to the tail, as ground. The EEG activity was sampled at 120Hz for an hour. The accuracy and precision of the EEG measurement was performed using Fourier analysis and signal energy. For this, the digital signal was divided into sections successive of 3 seconds and was decomposed into four frequency bands: delta (0.3 to 4Hz), theta (4-8Hz), alpha (8-12Hz) and beta (12-30Hz) and energy (µV²) of the series of time filtered were calculated. The method allowed the acquisition of non-invasive electrical brain signals in conscious rats and their frequency patterns were in agreement with previous studies that used surgical procedures to acquire EEG in rats. This system showed accuracy and precision and will allow further studies on behavior and to investigate the action of drugs on the central nervous system in rats without surgical procedures.


Este trabalho apresenta um método não invasivo para a aquisição de sinal elétrico cerebral em ratos. Utilizou-se um sistema de eletroencefalografia EEG desenvolvido para bovino e adaptado para ratos. O sistema bipolar de eléctrodos (eléctrodos de agulha) foi colado na superfície da cabeça do animal, sem procedimentos cirúrgicos e outro eletrodo foi colado na cauda, como terra. A atividade do EEG foi amostrada em 120Hz durante uma hora. Foi calculada a exatidão e a precisão da medida de EEG usando análise de Fourier e energia do sinal. Para isso, o sinal digital foi dividido em trechos sucessivos de 3 segundos, decomposto em quatro faixas de frequência: delta (0,3-4Hz), teta (4-8Hz), alfa (8-12Hz) e beta (12-30Hz) e a energia (µV²) das séries de tempo filtradas foram calculadas. O método não invasivo permitiu adquirir sinais elétricos cerebrais em ratos conscientes e seus padrões de frequências foram de acordo com trabalhos anteriores, que utilizaram procedimentos cirúrgicos para adquirir EEG em ratos. Esse sistema apresentou exatidão e precisão e permitirá novos estudos sobre comportamento e para investigar a ação de drogas no sistema nervoso central sem procedimentos cirúrgicos em ratos.

2.
Arq. bras. cardiol ; 63(3): 197-201, set. 1994. tab
Article in Portuguese | LILACS | ID: lil-155550

ABSTRACT

PURPOSE--To search for the existence and degree of correlation between total 12 lead ECG amplitude and the sum of RaVL + SV3 > 28 mm (for men) or > 20mm (for women) and left ventricular hypertrophy (LV mass calculated by echocardiography > 215g for both sexes). METHODS--ECG and echocardiograms of 227 consecutive patients were examined and submitted to statistical analysis searching for correlation between total 12 lead ECG amplitude and Cornell criteria and LV mass (ASE formula modified by Devereux). RESULTS--Patients had ischemic heart disease, hypertension, valvular disease, cardiomyopathy or other less common heart diseases, or had no cardiac illness at all. There was statistically significant association of total 12 lead amplitude > 120mm and Cornell criteria with LV mass > 215g (p = 0.02 and p = 0.01 respectively). Total ECG amplitude showed 74.3//sensitivity, 42.6//specificity, and 52.4//accuracy. Cornell criteria showed values of 37.8//, 82.7//and 68.7//respectively. CONCLUSION--Total 12-lead amplitude presented limited diagnostic performance for detecting LV hypertrophy, as well as did ECG Cornell criteria, although the latter was more specific and more accurate


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Hypertrophy, Left Ventricular/diagnosis , Electrocardiography , Aged, 80 and over , Sex Factors , Predictive Value of Tests , Hypertrophy, Left Ventricular/physiopathology , Age Factors
3.
Arq. bras. med ; 62(5): 357-60, set.-out. 1988. mapas, tab
Article in Portuguese | LILACS | ID: lil-72109

ABSTRACT

A transfusäo de sangué é reconhecida como o segundo mais importante modo de transmissäo da doença de Chagas. Este estudo faz um levantamento dos métodos empregados em diversos bancos de sangue para detectar doadores infectados e prevenir esta iatrogenia e compara as áreas controladas por órgäos oficiais com aquelas de maior prevalência da doença


Subject(s)
Humans , History, 20th Century , Chagas Disease/transmission , Blood Transfusion/adverse effects , Brazil , Prevalence
4.
Acta méd. (Porto Alegre) ; (?): 1-10, jun. 1984-jul. 1985. mapas, tab
Article in Portuguese | LILACS | ID: lil-48295

ABSTRACT

A transfusäo de sangue é reconhecida como o segundo mais importante modo de transmissäo da Doença de Chagas. Este estudo faz um levantamento dos métodos empregados em diversos Bancos de Sangue para detectar doadores infectados e prevenir esta iatrogenia e compara as áreas controladas por órgäos oficiais com aquelas de maior prevalência da Doençça


Subject(s)
Humans , Chagas Disease/transmission , Blood Transfusion/adverse effects , Brazil
SELECTION OF CITATIONS
SEARCH DETAIL