Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Radiol. bras ; 53(6): 390-396, Nov.-Dec. 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1136116

ABSTRACT

Abstract Objective: To identify the main hemorrhagic complications after percutaneous nephrolithotomy, as well as the results obtained with transcatheter arterial embolization (TAE) at an interventional radiology center. Materials and Methods: This was a retrospective analysis of patients undergoing TAE for the treatment of hemorrhagic complications after percutaneous nephrolithotomy. All patients underwent computed tomography angiography (CTA). Results: We evaluated a total of nine patients. At emergency department readmission, the most common symptom was macroscopic hematuria, which was seen in five patients. Three patients had an isolated pseudoaneurysm, two had a pseudoaneurysm together with active bleeding (perirenal hematoma), and one had a pseudoaneurysm together with arteriocalyceal fistula. Arteriovenous fistula was diagnosed in three patients and was not seen in combination with other vascular lesions. We did not identify arteriocalyceal fistula in isolation. Five patients underwent TAE with 6 × 15 mm and 6 × 20 mm microcoils. Four patients underwent TAE with n-butyl-2-cyanoacrylate and ethiodized oil. Follow-up CTAs revealed no complications. Conclusion: Because of its high diagnostic accuracy, CTA provides the interventional radiologist with valuable data for individualized therapeutic planning. The TAE procedure is safe and effective. It can therefore be used as a first-line treatment for hemorrhagic complications resulting from percutaneous renal procedures.


Resumo Objetivo: Demonstrar as principais complicações hemorrágicas após nefrolitotripsia percutânea, bem como os resultados após o tratamento por embolização arterial transcateter (EAT) em um centro de radiologia intervencionista. Materiais e Métodos: Coleta e análise de dados retrospectivos de pacientes submetidos a EAT por complicações hemorrágicas após nefrolitotripsia percutânea. Resultados: O sintoma mais comum foi hematúria macroscópica, presente em cinco pacientes no momento da readmissão ao pronto-socorro, e nestes pacientes identificamos três pseudoaneurismas isolados, dois casos de combinação de pseudoaneurisma e sangramento ativo (hematoma perirrenal) e um caso de associação de pseudoaneurisma e fístula arteriocalicinal. Fístula arteriovenosa foi diagnosticada em três pacientes, não sendo observada em associação com outras lesões vasculares. Não identificamos fístula arteriocalicinal isolada, somente associada a pseudoaneurisma. Cinco pacientes foram submetidos a embolização por micromolas 6 × 15 mm e 6 × 20 mm. Quatro pacientes foram submetidos a embolização por Histoacryl e Lipiodol. Não observamos complicações pela angiotomografia computadorizada de controle. Conclusão: A angiotomografia computadorizada apresenta alta acurácia diagnóstica e guarnece o radiologista intervencionista de dados para um planejamento terapêutico individualizado. EAT é um procedimento seguro e eficaz e pode ser utilizado como primeira linha para o tratamento de complicações hemorrágicas resultantes de procedimentos percutâneos renais.

2.
Rev. bras. cir. cardiovasc ; 28(2): 167-175, abr.-jun. 2013. ilus, tab
Article in English | LILACS | ID: lil-682426

ABSTRACT

OBJECTIVES: The purpose of our study was to establish, with an entirely noninvasive method, transthoracic Doppler echocardiography, criteria for patency of composite left internal thoracic artery grafts when placed on the left anterior descending artery and other branches of the left coronary system. METHODS: The control group comprised 20 patients with single graft and 20 patients with composite graft; all forty having their patency confirmed by coronary angiogram (CA). In this control group, two Doppler echocardiographic variables, diastolic mean velocity-time and integral diastolic peak velocity to systolic peak velocity ratio were recorded. For each variable, established cut-off points were established, using the ROC (Receiver Operator Characteristic) curves, to identify criteria which could differentiate the composite grafts. Only patients with composite grafts were included in the 159-patients study group. The criteria established by the cut-off points in the control group were then applied to detect patency using a diastolic fraction of > 0.5 as the gold standard. The sensitivity, specificity, and positive and negative predictive values of these two criteria were determined. RESULTS: In the control group, cut-off points of 0.71 and 0.09m were established for the diastolic peak velocity/systolic peak velocity ratio and for diastolic mean velocity-time integral, respectively. In the study group phase, the sensitivity and negative predictive value of the diastolic peak velocity/systolic peak velocity > 0.71 criterion were 36% and 11%, respectively. Diastolic mean velocity-time integral > 0.09m criterion, were 40% and 10.48%. The specificities and positive predictive values of each criterion were 100%. CONCLUSION: Values reaching the criteria established for each variable indicate high probability of composite graft patency. Lower values have a large proportion of false negatives and are not conclusive as patency criteria.


OBJETIVO: O objetivo deste estudo é estabelecer parâmetros preditores de perviedade, avaliados por Dopplerfluxometria, do enxerto composto de artéria torácica interna esquerda, quando revasculariza a artéria interventricular anterior e outro ramo do sistema esquerdo. MÉTODOS: O grupo controle foi formado por 20 pacientes com enxerto simples e 20 pacientes com enxerto, composto cuja perviedade foi confirmada por cineangiocoronariografia. No grupo controle, as variáveis de fluxo relação velocidade pico diastólico/velocidade pico sistólico e integral da velocidade média/tempo na diástole foram registradas. Para cada variável, estabeleceram-se pontos de corte para identificar enxertos compostos, usando-se curvas ROC (receiver operator characteristic). No grupo estudo, foram avaliados 159 pacientes com enxerto composto, determinando-se os dois parâmetros de fluxo. Pontos de cortes estabelecidos no grupo controle foram usados para determinar sensibilidade, especificidade, valores preditivos positivo e negativo de cada variável relacionada à perviedade dos enxertos, tomando-se como referência a fração diastólica > 0,5. RESULTADOS: No grupo controle, os pontos de corte estabelecidos para as variáveis velocidade pico diastólico/velocidade pico sistólico e integral velocidade média/tempo na diástole foram, respectivamente, 0,71 e 0,09m. No grupo estudo, a sensibilidade para a velocidade pico diastólico/velocidade pico sistólico e integral da velocidade média/tempo na diástole, considerando seus pontos de corte, foi de 36,4% e 40%, respectivamente. Os respectivos valores preditivos negativos foram 11% e 10.48%, enquanto especificidade e valor preditivo positivo foram de 100% para os dois parâmetros. CONCLUSÃO: Valores maiores ou iguais aos estabelecidos para cada variável indicam alta probabilidade de perviedade do enxerto composto. Valores inferiores apresentam grande proporção de falsos negativos, não sendo conclusivos quanto à perviedade.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Echocardiography, Doppler/standards , Mammary Arteries , Vascular Grafting , Vascular Patency , Blood Flow Velocity , Coronary Artery Bypass/methods , Diastole/physiology , Mammary Arteries/transplantation , Reference Values , Reproducibility of Results , ROC Curve , Statistics, Nonparametric , Systole/physiology
SELECTION OF CITATIONS
SEARCH DETAIL