Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Arq. Ciênc. Vet. Zool. UNIPAR (Online) ; 24(1, cont.): e2403, jan-jun. 2021. tab, graf
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1252764

ABSTRACT

O Whatman FTA-Card® é um papel-filtro quimicamente tratado, destinado à coleta, transporte, armazenamento de amostras para posterior extração de ácidos nucléicos. A tecnologia FTA-Card® é utilizada para manter estável DNA e RNA em temperatura ambiente, podendo ser utilizados para fixação de uma ampla variedade de material orgânico ou tecidos. Foram realizados testes para certificar sua eficiência na conservação do material a ser analisado com o intuito de eliminar a cadeia fria de conservação, agilizando o processo e diminuindo os custos da execução de exames moleculares associados ao diagnóstico de patologias. Foram testadas oito amostras de felinos na forma de sangue total e soro, para a extração utilizou-se o kit Magazorb RNA Total mini-prep kit (Promega®, EUA), para o diagnóstico foi utilizada a técnica de PCR em tempo real para amplificar o gene CI2 de mamíferos, a fim de visualizar a eficácia na conservação de ácidos nucleicos. A utilização desse método torna possível que o material biológico seja enviado por serviços de transporte postais, reduzindo os custos e viabilizando diagnósticos provenientes de áreas mais remotas.(AU)


Whatman FTA-Card® is a chemically treated filter paper intended for the collection, transport, and storage of samples for later extraction of nucleic acids. FTA-Card® technology is used to keep DNA and RNA stable at room temperature and can be used to fix a wide variety of organic material or tissues. Tests were carried out to certify its efficiency in the conservation of the material to be analyzed in order to eliminate the cold conservation chain, speeding up the process and decreasing the costs of performing molecular tests associated with the diagnosis of pathologies. By using this method, biological material can be sent by postal transport services, reducing costs and making diagnoses from more remote areas feasible. Samples of feline specimens were tested in the form of whole blood and serum, using the Magazorb RNA Total mini-prep kit (Promega®, USA) for the extraction. Diagnosis was performed using real-time PCR technique to amplify the mammalian CI2 gene in order to visualize the effectiveness in conserving nucleic acids.(AU)


Whatman FTA-Card® es un papel de filtro tratado químicamente, destinado a la recogida, transporte, almacenamiento de muestras para su posterior extracción de ácidos nucleicos. La tecnología FTA-Card® se usa para mantener el ADN y el ARN estables a la temperatura ambiente y se puede usar para la fijación de una amplia variedad de materiales o tejidos orgánicos. Se realizaron pruebas para certificar su eficiencia en la conservación del material a analizar con el fin de eliminar la cadena de frío de conservación, agilizando el proceso y reduciendo los costos de realización de pruebas moleculares asociadas al diagnóstico de patologías. Se analizaron ocho muestras felinas en forma de sangre total y suero, para la extracción se utilizó el mini-prep kit Magazorb RNA Total (Promega®, USA), para el diagnóstico se utilizó la técnica de PCR en tiempo real para amplificar el CI2 de mamífero gen, con el fin de visualizar la efectividad en la conservación de ácidos nucleicos. El uso de ese método permite el envío de material biológico por los servicios de transporte postal, lo que reduce los costes y permite realizar diagnósticos desde zonas más remotas.(AU)


Subject(s)
Biocompatible Materials , DNA , Real-Time Polymerase Chain Reaction
2.
J. Bras. Patol. Med. Lab. (Online) ; 56: e3582020, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1143141

ABSTRACT

ABSTRACT Introduction: Although reverse transcription-polymerase chain reaction (rRT-PCR) is the gold standard method for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), some factors, such as the presence of amplification inhibitors, lead to false-negative results. Objective: Here we describe the differences between rRT-PCR results for SARS-CoV-2 infection in normal and diluted samples, simulating the need for dilution due to the presence of amplification inhibitors. Material and method: Viral ribonucleic acid (RNA) from samples of nasopharyngeal swabs from 20 patients previously detected as "Negative" and 21 patients detected as "Positive" for SARS-CoV-2 was performed with the EasyExtract DNA-RNA kit (Interprise®). The rRT-PCR was performed with the OneStep/COVID-19 kit (IBMP), with normal and diluted (80 µl of H2O RNAse free) samples, totaling 82 tests. Results: The results indicate that there is an average variation (a < 0.05) delaying the Cq between the results of amplification of the internal control (IC), N gene (NG), and ORF1ab (OF), 1.811 Cq, 3.840 Cq, and 3.842 Cq, respectively. Discussion: The extraction kit does not completely purify the inhibitor compounds; therefore, no amplified product result may occur. In this study, we obtained a 19.04% false-negative diagnosis after sample dilution; this process reduces the efficiency of rRT-PCR to 29.8% in detecting SARS-CoV-2. Conclusion: Knowing the rRT-PCR standards of diluted samples can assist in the identification of false-negative cases and, consequently, avoid incorrect diagnosis.


RESUMEN Introducción: Aunque la reacción en cadena de la polimerasa con transcriptasa reversa en tiempo real (rRT-PCR) sea el método de referencia para detección del coronavirus tipo 2 del síndrome respiratorio agudo grave (Sars-CoV-2), algunos factores como la presencia de inhibidores de amplificación conducen a resultados falsos negativos. Objetivo: Describimos las diferencias entre los resultados de rRT-PCR para infección por Sars-CoV-2 en muestras normales y diluidas, simulando la necesidad de dilución debido a la presencia de inhibidores de amplificación. Material y método: La extracción de ácido ribonucleico (ARN) viral de muestras de hisopos nasofaríngeos de 20 pacientes previamente detectados como "negativos" y 21 pacientes detectados como "positivos" para Sars-CoV-2 se realizó con el kit Easy Extract DNA-RNA (Interprise®). La rRT-PCR se realizó con el kit OneStep/Covid-19 (IBMP), con muestras normales y diluidas (80 µl de H2O libre de ARNasa), totalizando 82 pruebas. Resultados: Los resultados indican que hay una variación media (a < 0,05) retrasando el ciclo de cuantificación (Cq) entre los resultados de amplificación del control interno (CI), gen N (GN) y ORF1ab (OF) de 1,811 Cq, 3,840 Cq y 3,842 Cq. Discusión: El kit de extracción no purifica completamente los compuestos inhibidores; por lo tanto, puede ocurrir no amplificación. Obtuvimos un diagnóstico falso negativo de 19,04% después de la dilución de la muestra; ese proceso reduce la eficiencia de la rRT-PCR hacia 29,8% en la detección de Sars-CoV-2. Conclusión: Conocer los patrones de la rRT-PCR de muestras diluidas puede ayudar en la identificación de casos falsos negativos y, por consiguiente, evitar un diagnóstico equivocado.


RESUMO Introdução: Embora a reação em cadeia da polimerase de transcrição reversa (rRT-PCR) seja o método padrão-ouro para detecção de coronavírus da síndrome respiratória aguda grave 2 (SARS-CoV-2), alguns fatores como a presença de inibidores de amplificação levam a resultados falso negativos. Objetivo: Descrevemos as diferenças entre os resultados de rRT-PCR para infecção por SARS-CoV-2 em amostras normais e diluídas, simulando a necessidade de diluição devido à presença de inibidores de amplificação. Material e método: A extração de ácido ribonucleico (RNA) viral de amostras de suabes nasofaríngeos de 20 pacientes previamente detectados como "negativos" e 21 pacientes detectados como "positivos" para SARS-CoV-2 foi realizada com kit o EasyExtract DNA-RNA (Interprise®). A rRT-PCR foi realizada com o kit OneStep/COVID-19 (IBMP), com amostras normais e diluídas (80 µl de H2O RNAse-free), totalizando 82 testes. Resultados: Os resultados indicam que existe uma variação média (a < 0,05) atrasando o Cq entre os resultados de amplificação do controle interno (CI), gene N (GN) e ORF1ab (OF) de 1,811 Cq, 3,840 Cq e 3,842 Cq, respectivamente. Discussão: O kit de extração não purifica completamente os compostos inibidores, portanto, pode ocorrer não amplificação. Obtivemos um diagnóstico falso negativo de 19,04% após a diluição da amostra; esse processo reduz a eficiência da rRT-PCR para 29,8% na detecção de SARS-CoV-2. Conclusão: Conhecer os padrões da rRT-PCR de amostras diluídas pode auxiliar na identificação de casos falso negativos e, consequentemente, evitar um diagnóstico incorreto.

SELECTION OF CITATIONS
SEARCH DETAIL