Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Japanese Journal of Cardiovascular Surgery ; : 181-183, 2011.
Article in Japanese | WPRIM | ID: wpr-362090

ABSTRACT

A 61-year-old man was referred to our hospital for treatment of hemolytic anemia after ascending aortic replacement aortic dissection. Cine mode magnetic resonance imaging (MRI) showed stenosis at the proximal anastomostic site of a Teflon strip. We diagnosed hemolytic anemia induced by collision of red blood cells on the inverted felt strip. Conservative therapy with Sarpogrelate and β-blockers was effective to treat his hemolytic anemia. However, 7 years later he was re-admitted because of infective endocarditis at the aortic valve, and underwent aortic root replacement. Intraoperative findings showed a stiff and inverted Teflon felt strip causing stenosis of the proximal anastomosis. Hemolytic anemia should be considered a rare complication of using a Teflon felt strip to reinforce anastomosis for acute aortic dissection.

SELECTION OF CITATIONS
SEARCH DETAIL