Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
International Journal of Traditional Chinese Medicine ; (6): 849-853, 2018.
Article in Chinese | WPRIM | ID: wpr-693682

ABSTRACT

Objective Experimental model of experimental autoimmune Myasthenia Gravis (EAMG) were established to explore the effect of Zini-Huangqi-Gegen decoction and Peiyuan-Guben powder on EAMG rats model.Methods Experimental animals were randomly divided into the control group (n=10) and the model group (n=30).The model rats were induced by murine AChR-α97-116 peptide immunostaining for EAMG rats model.After the first immunization,the general condictions and body weight of rats were observed,and the Lennon score was used to evaluate the rats.The second immunization was performed on the 1 1th day after the first immunization.On the 15th day after the first immunization,the rats were randomly divided into the model group(n=8),Huangqi-Gegen decoction and Peiyuan-Guben powder group (abbreviated Huangpei group,n=8) and Prednisone group (n=8) according to the Lennon score.Huangpi group rats were treated with Huangqi-Gegen decoction (21.5 g/kg) combined with Peiyuan-Guben powder (0.8 g/kg),prednisone group with 0.005 4 g/kg prednisone aqueous solution,the control group and the model group oral volume of distilled water.The rats were administered with a body weight of 10 ml/kg once a day for a total of 56 days.At the 70th day after the first immunization,serum was extracted from the rats.The Anti-AChR-α97-116 IgG and its subtype in serum were detected by ELISA.The IL-4,IL-10,IL-17 in serum were detected by ELISA.Results Compared with the model group,the weight of the rats in the Huangpei group and the prednisone group significantly increased after the 28th day of the first immunization (P<0.05).After the 36nd day of the first immunization,the Lennon score of the Huangpei group significantly decreased (P<0.05).At the end of the administration,the amplitude of EMG amplitude attenuation (41.83% ± 7.45% vs.67.76% ± 4.32%) in the Huangpei group significantly decreased (P<0.05),and the serum IgG (1.15 ± 0.07 vs.1.24 ± 0.08),IgG1 (0.17 ± 0.01 vs.0.25 ± 0.03),IL-4 (16.54 ± 1.66 pg/ml vs.25.64 ± 1.74 pg/ml),IL-10 (113.65 ± 12.87 pg/ml vs.121.54 ± 10.44 pg/ml),IL-17 (43.58 ± 3.54 pg/ml vs.65.76 ± 3.59 pg/ml) in the rat serum significantly decreased (P<0.05).Conclusions Huangqi-Gegen decoction and Peiyuan-Guben powder can increase the body weight of rats,decrease the concentration of AChR-Ab in serum,the concentrations of IL-4,IL-10 and IL-17 in serum,and effectively improve the symptoms of EAMG rats.

2.
Chinese Journal of Medical Imaging Technology ; (12): 412-415, 2018.
Article in Chinese | WPRIM | ID: wpr-706253

ABSTRACT

Objective To explore the value of prenatal MRI signs in diagnosis of placenta accreta.Methods MRI data of 163 pregnant women with suspected placenta accreta were retrospectively reviewed.According to the results of cesarean section,they were divided into placenta accreta group (n =136) or without placenta accreta group (n =27).The differencesof MRI signs between the two groups were compared.Taking cesarean section results as the gold standard,the sensitivity,specificity,positive and negative predictive value of MRI signs were calculated,respectively.Results Uterine bulging,abnormal vessels and hypointense T2WI bands at junction of placental and myometrium,as well as uterine recess had statistical differences between the two groups (all P<0.05).No statistical difference of placental heterogeneity,focal interruptions in myometrial wall,uterine penetration and parametrium implantation nor protrusion of placenta into cervix was found between the two groups (all P>0.05).The MRI signs of uterine penetration and parametrium implantation,uterine recess,protrusion of placenta into cervix yielded a specificity and positive predictive value of 100%,respectively.Conclusion Prenatal MRI has high efficacy in the diagnosis of placenta accrete.Placenta accrete should be highly suspected especially in the presence of uterine penetration and parametrium implantation,uterine recess and protrusion of placenta into the cervix.

3.
Chinese Journal of Medical Imaging Technology ; (12): 590-593, 2017.
Article in Chinese | WPRIM | ID: wpr-608677

ABSTRACT

Objective To assess the effectiveness of iterative metal artifact reduction (IMAR) on metal artifacts reduction in thorax scan.Methods Thoracic phantom with two pedicle screws implanted in both sides of the T5 vertebrae was used,with the scan parameters of 130 kV and CARE Dose 4D,the phantom was scanned with and without the screws respectively.Images without screws were reconstructed with FBP.Images with screws were reconstructed with FBP and IMAR respectively.Three ROIs were selected on tissues including aorta,pulmonary and paravertebral soft tissue on image slice adjacent to the screws.The CT value and standard deviations (noise) of ROIs were measured,and the deviation of CT value (△HU) was calculated as the difference between CT values in images with and without screws.Twenty-six cases who received chest CT examination and with pedicle screw implant in scanning range were collected.The scanning parameters and image reconstruction methods were the same as phantom scan.The CT value (HU) of metal artifacts adjacent to vertebrae and dorsal soft tissue was measured,and the image quality of reconstructed image by two skilled radiologists independently was evaluated.Results In the phantom after implanted screws,the noise were significantly reduced by IMAR compared to FBP in all the three ROIs of aorta,pulmonary and paravertebral soft tissue (P<0.05),and the △HU was significantly smaller in IMAR compared to that with FBP (P<0.01).In 26 patients,there were significant differences in CT value of vertebral bone tissue and dorsal soft tissue between FBP and IMAR (P<0.05),and the subjective evaluation scores of the two image reconstruction methods showed a statistically significant difference (P<0.05).Conclusion IMAR can significantly reduce streak artifacts of metal implant and adjuste the CT values of artifact affected tissues to make it more close to the true value without metal implant.

4.
Chinese Journal of Medical Imaging Technology ; (12): 1526-1530, 2017.
Article in Chinese | WPRIM | ID: wpr-662131

ABSTRACT

Objective To compare the diagnostic value of MR examination with fast imaging employing steady state acquisition (FIESTA) and single shot fast spin echo (SSFSE) sequences for normal fetal thymuses.Methods Totally 366 normal fetuses were examined using MRI with FIESTA and SSFSE sequences,and the anatomy and MR manifestations of thymuses were observed.Kappa analysis and x2 test were performed.The transverse area (TA) and transverse diameter (TD) were measured on the "three vessel" level,while the superoinferior diameter (SID) was measured on the sagittal level.The mean value of these parameters at different gestational were calculated,and the regression equations of each parameter and gestational age were fitted.Results Two doctors had good agreements with the images of FIESTA and SSFSE sequences (Kappa=0.745,0.802,both P<0.01).The clear rate of FIESTA and SSFSE sequences was 86.34% (632/732) and 37.70% (276/732) respectively,and the differences were significant (x2 =367.520,P<0.001).The thymic size increased with the gestational age,and the regression equations and correlation coefficients were:TA =-5.80 + 0.35 ×gestational (r=0.820,P<0.01),TD=-14.59+1.63×gestational (r=0.817,P<0.01),and SID=-9.63+1.44×gestational (r=0.778,P<0.01).Conclusion The subtle structure and contour of fetal thymus showed with FIESTA sequence are clearer than those of SSFSE sequence.MRI can clearly show fetal thymus after 22 weeks of pregnancy.

5.
Chinese Journal of Medical Imaging Technology ; (12): 1526-1530, 2017.
Article in Chinese | WPRIM | ID: wpr-659453

ABSTRACT

Objective To compare the diagnostic value of MR examination with fast imaging employing steady state acquisition (FIESTA) and single shot fast spin echo (SSFSE) sequences for normal fetal thymuses.Methods Totally 366 normal fetuses were examined using MRI with FIESTA and SSFSE sequences,and the anatomy and MR manifestations of thymuses were observed.Kappa analysis and x2 test were performed.The transverse area (TA) and transverse diameter (TD) were measured on the "three vessel" level,while the superoinferior diameter (SID) was measured on the sagittal level.The mean value of these parameters at different gestational were calculated,and the regression equations of each parameter and gestational age were fitted.Results Two doctors had good agreements with the images of FIESTA and SSFSE sequences (Kappa=0.745,0.802,both P<0.01).The clear rate of FIESTA and SSFSE sequences was 86.34% (632/732) and 37.70% (276/732) respectively,and the differences were significant (x2 =367.520,P<0.001).The thymic size increased with the gestational age,and the regression equations and correlation coefficients were:TA =-5.80 + 0.35 ×gestational (r=0.820,P<0.01),TD=-14.59+1.63×gestational (r=0.817,P<0.01),and SID=-9.63+1.44×gestational (r=0.778,P<0.01).Conclusion The subtle structure and contour of fetal thymus showed with FIESTA sequence are clearer than those of SSFSE sequence.MRI can clearly show fetal thymus after 22 weeks of pregnancy.

SELECTION OF CITATIONS
SEARCH DETAIL