Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1119-1124, 2019.
Article in Chinese | WPRIM | ID: wpr-751331

ABSTRACT

@#Objective    To explore the practical feasibility of the weaving technique for pectus carinatum. Methods    From January 2011 to December 2018, a total of 51 patients with pectus carinatum, including 47 males and 4 females at age of 9-29 (13.7±2.9) years, were applied with minimally invasive waving technique for the correction. The steel plate was inserted through the subcutaneous layer, intercostal space and over the sternal surface under direct thoracoscopic vision. The number of implanted steel plates was determined by the degree of chest wall deformity. The steel plate was removed 2 years after surgery. Results    All the operations were successfully completed, the average operation time was 63.9±15.8 min, the amount of bleeding was 19.8±8.8 mL, and the duration of postoperative hospitalization was 4.6±1.6 d. The adverse events included intercostal artery injury (n=2), pneumothorax (n=4), pleural effusion (n=3) and skin rupture (n=1). And there were 29 patients of moderate pain (numerical rating scale 4-6 points) on the first day after surgery, but no patient was asked to remove the steel palate due to intolerable discomfort. All patients were followed up after plate placement. Of the 51 patients, the plates were removed in 37 patients until 2 years after placement, and the duration of postoperative hospitalization was 1.4±0.5 d. After 33 (1-48) months of routine follow-up after the removal of the plate, 22 patients achieved excellent outcomes and 9 patients with good outcomes. Besides, there were 5 patients with fair outcome and 1 patient with poor outcome. No adverse effect was found in growth and development after the steel plate placement. Conclusion    Minimally invasive weaving technique is a safe, feasible, effective and individualized operation for pectus carinatum with substantial thoracic reconstruction.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 153-158, 2018.
Article in Chinese | WPRIM | ID: wpr-749816

ABSTRACT

@#Objective    To evaluate the clinical efficacy of fistula repair by stapler technique in patients with cervical tracheoesophageal fistula. Methods    Retrospective analysis of 8 patients with cervical tracheoesophageal fistula who accepted operative treatment in the Department of Thoracic Surgery, Lanzhou University Second Hospital from October 2014 to October 2016 was conducted. There were 5 males and 3 females at a mean age of 46.4±13.9 years ranging from 23 to 67 years. The fistula was induced by tracheal intubation in 4 patients, by esophageal foreign bodies in 2, by tracheal stent in 1 and by esophageal diverticulum in 1. The fistula was closed by stapler technique. The surgical effects were evaluated through Karnofsky performance score (KPS), image assessment, patient satisfaction score and assessment of improvement in feeding-induced bucking. Results    The operations were performed successfully with time of 117.5±6.6 min and intraoperative blood loss of 60.0±7.0 ml. After the operations, the patients did not suffer incision bleeding and infection, hoarseness, dyspnea, drinking-induced bucking, fistula relapse, tracheoesophageal stenosis or any other complications, and no death occurred during the perioperative period. The chest X-ray test was performed 1 week later showed that the pulmonary infection disappeared, and only 1 patient suffered from esophageal stenosis 1 year later. The postoperative KPS score was 90.0±7.0 points, which significantly improved in contrast to preoperation (P<0.01).   Postoperative pulmonary infection area reduced significantly (P<0.05), tracheoesophageal fistula disappeared, postoperative patients satisfaction rate was 90%, and assessment of feeding-induced bucking was excellent. Conclusion    Using stapler technique to repair cervical tracheoesophageal fistula is safe, easy and useful, with less operation time and postoperative complications.

SELECTION OF CITATIONS
SEARCH DETAIL