Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Chinese Journal of Tissue Engineering Research ; (53): 5722-5729, 2016.
Article in Chinese | WPRIM | ID: wpr-500742

ABSTRACT

BACKGROUND:Cerebral aneurysm is a kind of mortal hemangioma, and its treatments such as endovascular embolization and clipping both cause high postoperative recurrence rate and mortality. So the stent implantation for cerebral aneurysm is coming into being. OBJECTTVE:To evaluate the hemodynamic parameters after stent implantation into cerebral aneurysm and to provide a novel feasible strategy for clinical treatment. METHODS:A retrospective analysis was preformed based on the CT image data of 11 patients with cerebral aneurysm from the Affiliated Hospital of Xinjiang Medical University. Firstly, the flexible and solid model of cerebral aneurysm was established by the MIMICS and reverse engineering. Secondly, the matching stent model was implanted into the cerebral aneurysm, and then the blood flow structure of cerebral aneurysm was analyzed by the fluid dynamics theory and the Fluent with the method of two-way flow solid coupling. Final y, comparative analysis of the kinetic parameters of cerebral aneurysm before and after implantation, including wal pressure, blood velocity, path line of the blood flow, wal shear stress, wal deformation was conducted, and blood flow characteristics after stent implantation were analyzed under different entrance velocity. RESULTS AND CONCLUSION:After implantation, the wal surface pressure was reduced about 61.1%;the blood flow velocity around the stent and the inside of the cerebral aneurysm was decelerated obviously;under setting 2 000 lines of blood flow, the number of path line of blood flow into the cerebral aneurysm reduced about 75.0%, the maximum wal shear stress decreased about 79.3%, and the maximum wal deformation reduced to a lower level. The entrance velocity was respectively v1=0.1 m/s, v2=0.2 m/s, v3=0.3 m/s and the wal pressure was in a gradient ascent;the wal shear stress increased with the velocity, meanwhile,τzou (left neck of aneurysm)<τzhong (aneurysm )<τyou (right neck of aneurysm). The path lines of blood flow mainly concentrated in the top of the aneurysm, and the blood velocity markedly affected the surface deformation. These results indicate that main hemodynamic parameters are obviously improved after stent implantation into cerebral aneurysm, and the blood velocity should never be neglectful in the treatment process.

2.
Indian J Pathol Microbiol ; 2013 Jul-Sept 56 (3): 243-247
Article in English | IMSEAR | ID: sea-155876

ABSTRACT

Background: The secreted aspartyl proteinases 2 (Sap2) of Candida albicans (C. albicans) is a potential marker of candididasis. It is a virulence factor associated with adherence and tissue invasion. Aim: In order to detect Sap2 in clinical sera, we developed an indirect competitive enzyme-linked immunosorbent assay (ELISA). Materials and Methods: Polyclonal antibodies were produced for Sap2 by injecting Sap2 into a New Zealand White inbred rabbit. They could be used at a dilution exceeding 1:1200 in an indirect ELISA, and detected Sap2 concentration up to 1 ng/mL. Results: Of the 286 cancer serum samples tested, 16.8% were found as candidiasis. The test was simple and economical to perform and had a level of sensitivity for detection of low-titer positive sera; thus, it may be proven to be of value in epidemiological studies on candidiasis.

3.
Acta Physiologica Sinica ; (6): 639-645, 2012.
Article in Chinese | WPRIM | ID: wpr-333160

ABSTRACT

This study was undertaken to observe the effect of acute stress on seizure occurrence in chronic period of epileptic model rats. Lithium-pilocarpine (LiCl-PILO)-induced epileptic rat model was constructed. At the spontaneous recurrent seizure period, acute stress stimulations such as cat's urine and foot electrical shock were applied to observe the behavioral changes and seizure occurrence. The results showed that after the cat's urine stimulation, the self-directed behaviors of the epileptic model rats decreased significantly, while the risk assessment behaviors increased significantly. The seizure occurrence, however, was not observed during the 45 min after the stimulation. Applying electrical foot shocks also did not evoke seizures in epileptic model rats. On the contrast, intra-peritoneal injection of low dose of pentylenetetrazole (PTZ, 30 mg/kg) evoked seizure more efficiently, and the duration of seizure activity was extensively prolonged in epileptic model rats than that of control rats. Taken together, these results indicate that although applying stress stimulations such as cat's urine and electrical foot shock cause several behavioral changes, they are not severe enough to evoke seizure in epileptic model rats.


Subject(s)
Animals , Rats , Behavior, Animal , Disease Models, Animal , Epilepsy , Lithium Chloride , Pentylenetetrazole , Pilocarpine , Seizures , Stress, Physiological
SELECTION OF CITATIONS
SEARCH DETAIL