Braz. J. Psychiatry (São Paulo, 1999, Impr.) ; 44(5): 495-506, Sept.-Oct. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1403774

ABSTRACT

Objective: Positron emission tomography (PET) allows in vivo evaluation of molecular targets in neurodegenerative diseases, such as Alzheimer's disease. Mild cognitive impairment is an intermediate stage between normal cognition and Alzheimer-type dementia. In vivo fibrillar amyloid-beta can be detected in PET using [11C]-labeled Pittsburgh compound B (11C-PiB). In contrast, [18F]fluoro-2-deoxy-d-glucose (18F-FDG) is a neurodegeneration biomarker used to evaluate cerebral glucose metabolism, indicating neuronal injury and synaptic dysfunction. In addition, early cerebral uptake of amyloid-PET tracers can determine regional cerebral blood flow. The present study compared early-phase 11C-PiB and 18F-FDG in older adults without cognitive impairment, amnestic mild cognitive impairment, and clinical diagnosis of probable Alzheimer's disease. Methods: We selected 90 older adults, clinically classified as healthy controls, with amnestic mild cognitive impairment, or with probable Alzheimer's disease, who underwent an 18F-FDG PET, early-phase 11C-PiB PET and magnetic resonance imaging. All participants were also classified as amyloid-positive or -negative in late-phase 11C-PiB. The data were analyzed using statistical parametric mapping. Results: We found that the probable Alzheimer's disease and amnestic mild cognitive impairment group had lower early-phase 11C-PiB uptake in limbic structures than 18F-FDG uptake. The images showed significant interactions between amyloid-beta status (negative or positive). However, early-phase 11C-PiB appears to provide different information from 18F-FDG about neurodegeneration. Conclusions: Our study suggests that early-phase 11C-PiB uptake correlates with 18F-FDG, irrespective of the particular amyloid-beta status. In addition, we observed distinct regional distribution patterns between both biomarkers, reinforcing the need for more robust studies to investigate the real clinical value of early-phase amyloid-PET imaging.

2.
Radiol. bras ; 48(1): 26-32, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-741690

ABSTRACT

Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service. .


Objetivo: Avaliar a viabilidade de substituir o radioisótopo 18F pelo 99mTc no teste de linearidade em medidores de atividade. Materiais e Métodos: O teste foi realizado empregando-se fontes de 99mTc (62 GBq) e 18F (12 GBq), cujas atividades foram mensuradas até valores abaixo de 1 MBq. As razões e desvios entre as atividades experimentais e teóricas foram calculados e comparados. Resultados: Os desvios médios entre as atividades experimentais e teóricas para o 99mTc e 18F foram, respectivamente, 0,56 (± 1,79)% e 0,92 (± 1,19)%. A razão média entre as atividades indicadas pelo equipamento para a fonte de 99mTc quando mensurada no equipamento pré-ajustado para medir o 99mTc e 18F foi 3,42 (± 0,06), e para o 18F este valor foi 3,39 (± 0,05), razões consideradas constantes ao longo de todo o período de medida. Conclusão: Os resultados do teste utilizando o 99mTc são compatíveis com os adquiridos com o 18F, implicando na possibilidade de utilização de ambos os radioisótopos na realização do teste de linearidade. Esta informação, aliada ao elevado potencial de exposição e custos de aquisição do 18F, sugere que o 99mTc seja empregado na realização do teste de linearidade para clínicas que utilizam 18F, sem prejuízo para o procedimento e garantia da qualidade de um serviço de medicina nuclear. .

3.
Clinics ; 62(6): 741-748, 2007. ilus, graf, tab
Article in English | LILACS | ID: lil-471794

ABSTRACT

OBJECTIVE: In bone injury, repair results in local increased vascularity and bone marrow remodeling. Characterizing the vascular and metabolic imaging patterns of the proximal femur following an intertrochanteric osteotomy may help clinicians decide proper management of the patient. Our objective was to measure Doppler sonography and scintigraphy interval changes in the proximal femur following intertrochanteric osteotomy and compare imaging and histomorphometric measurements in the late post-operative stage (6 weeks after surgery) in a rabbit model of bone injury. MATERIALS AND METHODS: Both hips of 12 adult rabbits were imaged with power Doppler sonography and scintigraphy prior to and after (7 days and 6 weeks) unilateral osteotomy. Accuracy of the imaging methods was evaluated using hip operative status and histomorphometric results (vascular fractional area and number of vessels per area unit) as reference standard measures. RESULTS: A significant difference in the mean number of pixels was noted between operated and non-operated femura in late post-operative power Doppler examinations (P=0.049). Although without reaching statistical significance, the AUC of Doppler measurements (AUC=0.99) was numerically greater than the AUC of scintigraphy measurements (AUC=0.857±0.099) (P=0.15) in differentiating proximal femura with regard to their fractional vascular areas in the late post-operative stage. In contrast, scintigraphy tended to perform better (AUC=0.984±0.022) than Doppler ultrasound (AUC=0.746±0.131) to demonstrate the vascularity intensity per area unit (P=0.07) in the late stage. CONCLUSION: Our results warrant further investigation to determine the value of different imaging modalities for assessment of pathologic changes following hip surgery. Power Doppler sonography demonstrated larger AUCs (representing higher accuracy) for the discrimination of vascular fractional areas and scintigraphy, for discrimination...


OBJETIVO: Regeneração em casos de lesão óssea resulta em aumento da vascularização local e remodelamento da medula óssea adjacente. A caracterização imagenológica de padrões vasculares e metabólicos no fêmur proximal após uma osteotomia intertrocantérica pode auxiliar ortopedistas a decidirem qual a terapêutica mais apropriada. O objetivo deste estudo foi avaliar as alterações temporais observadas por ultra-sonografia Doppler e cintilografia no fêmur proximal após a realização de uma osteotomia intertrocantérica; e comparar achados imagenológicos e histomorfométricos no estágio pós-operatório tardio (6 semanas após a cirurgia) num modelo animal de lesão óssea. MATERIAIS AND MÉTODOS: Ambos os quadris de 12 coelhos adultos foram examinados por ultra-sonografia power Doppler e cintilografia antes e após (7 dias e 6 semanas) uma osteotomia unilateral. A acurácia dos métodos de imagem foi avaliada usando-se o status operatório dos quadris and os resultados histomorfométricos (área vascular fracional e número de vasos/unidade de área) como medidas de referência. RESULTADOS: Uma diferença significativa foi observada entre o número médio de pixels presentes no fêmur proximal operado e não-operado ao exame de power Doppler obtido no estágio pós-operatório tardio (P=0.049). Embora ser atingir significância estatística, a área abaixo da curva ("area-under-the-curve") dos exames de power Doppler (AUC=0.99) for numericamente superior à área abaixo da curva dos exames de cintilografia (AUC= 0.857±0.099) (P=0.15) para diferenciar fêmures proximais com relação a suas áreas vasculares fracionais no estágio pós-operatório tardio. Ao contrário, a cintilografia tendeu a apresentar uma "performance" diagnóstica superior (AUC=0.984±0.022) em relação ao Doppler (AUC=0.746±0.131) para demonstrar a quantidade de vasos por unidade de área (P=0.07) no estágio tardio. CONCLUSÃO: Nossos resultados despertam a importância de continuar-se investigando...


Subject(s)
Animals , Rabbits , Bone Diseases , Bone Diseases , Femur , Hip Joint , Osteotomy/methods , Bone Remodeling/physiology , Disease Models, Animal , Epiphyses, Slipped , Epiphyses, Slipped , Femur , Femur , Hip Joint , Hip Joint , Legg-Calve-Perthes Disease , Legg-Calve-Perthes Disease , Postoperative Period , Ultrasonography, Doppler/methods
4.
Radiol. bras ; 39(1): 33-38, jan.-fev. 2006. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-423388

ABSTRACT

OBJETIVO: O trabalho teve por objetivo padronizar o método e estabelecer valores normais da captacão renal absoluta do99mTc-DMSA em criancas. MATERIAIS E MÉTODOS: Vinte e duas criancas (idade de 7 meses a 10 anos; média de 4,5 anos) sem doenca renal prévia foram submetidas a cintilografia renal estática com 99mTc-DMSA. Dezoito apresentavam ultra-sonografia, uretrocistografia miccional, "clearance" de creatinina e padrão visual da cintilografia renal estática normais. Quatro criancas foram excluídas por não terem completado ou por apresentarem reducão do "clearance" de creatinina. A captacão absoluta de DMSA (DMSA-Abs) foi calculada como a porcentagem da atividade administrada retida em cada rim após seis horas da administracão do radiofármaco. RESULTADOS: Os valores de DMSA-Abs foram de 21,8 por cento n 3,2 por cento para o rim direito e de 23,1 por cento n 3,3 por cento para o rim esquerdo. Os valores da captacão absoluta não mostraram correlacão com a idade dos pacientes estudados, apesar da tendência de aumento do "clearance" de creatinina com a idade. CONCLUSAO: A definicão de valores normais da DMSA-Abs permite o emprego deste parâmetro na avaliacão inicial e acompanhamento de doencas renais, principalmente em pacientes com acometimento bilateral ou com rim único (nos quais a funcão diferencial direita X esquerda tem valor limitado).