Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Arch. cardiol. Méx ; 89(2): 172-180, Apr.-Jun. 2019. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1142179

ABSTRACT

Resumen Introducción y objetivos: En algunos centros el tamiz cardíaco no se realiza con la justificación de no tener el oxímetro adecuado. Comparamos la efectividad de dos marcas de oxímetros para realizarlo. Métodos: En los neonatos a término del Servicio de alojamiento conjunto del Hospital General de Occidente en Zapopan Jalisco México de mayo a noviembre del 2018 se realizó tamiz cardíaco según las guías de la Academia Americana de Pediatría con dos oxímetros, el Masimo SET (aprobado por la FDA) y el ChoiceMMed, comparando su efectividad para la detección de cardiopatías congénitas críticas, el tiempo de toma y los falsos positivos. Resultados: En cada grupo se analizaron 1,022 pacientes; con el oxímetro Massimo SET se obtuvieron 83 pruebas positivas (8.12%) de las cuales 22 casos presentaron alguna cardiopatía (26.5%), lo que representa una sensibilidad del 100%, una especificidad del 93.9%, un valor predictivo positivo del 26.5% y un valor predictivo negativo del 100% (Odd Ratio [OR]: 0.73; IC 95%: 0.6-0.8). Con el oxímetro ChoiceMMed se obtuvieron 168 pruebas positivas (16.4%), de las cuales 22 casos presentaron alguna cardiopatía (13.09%), con una sensibilidad del 100%, una especificidad del 85.4%, un valor predictivo positivo del 13.09% y un valor predictivo negativo del 100% (OR: 0.86; IC 95%: 0.8-0.92). En cuanto al tiempo para realizar el tamiz cardíaco, la media en minutos del oxímetro Masimo SET fue 5.38 y del oxímetro ChoiceMMed fue 9.7 minutos. Conclusiones: El oxímetro ChoiceMMed presentó mayor cantidad de falsos positivos y mayor tiempo de realización del tamiz cardíaco en comparación al Masimo SET, sin embargo, ambos presentan un valor predictivo negativo del 100%, siendo igualmente útiles como método de detección de cardiopatías críticas.


Abstract Introduction and objectives: In some centers the pulse oximetry is not performed with the justification of lack of the adequate oximeter. We compared the effectiveness of two brands of oximeters to perform it. Methods: In neonates a term of the joint housing service of a Hospital General de Occidente in Zapopan Jalisco Mexico from May-November 2018, an examination of the characteristics of the American Academy of Pediatrics with both oximeters (ChoiceMMed and Masimo SET) was carried out, comparing the detection of critical congenital heart disease (CCC), time of intake and false positives. Results: In each group 1,022 patients were analyzed; with the Masimo SET oximeter 83 positive tests were obtained (8.12%), of which 22 cases had some heart disease (26.5%), which represents a sensitivity of 100%, specificity of 93.9%, positive predictive value of 26.5% and negative predictive value of 100% (OR: 0.73; 95% CI: 0.6-0.8). With the ChoiceMMed oximeter, 168 positive tests were obtained (16.4%), of which 22 cases had some heart disease (13.09%), with a sensitivity of 100%, specificity of 85.4%, positive predictive value of 13.09% and negative predictive value 100% (OR: 0.86; 95% CI: 0.8-0.92). Regarding the time to perform the cardiac sieve, the mean in minutes of the Masimo SET oximeter was 5.38 and the ChoiceMMed oximeter was 9.7 minutes. Conclusions: The ChoiceMMed oximeter contains a large number of false positives and a greater number of echocardiograms and comparatively longer cardiac screen printing with Masimo SET, however, both with a negative predictive value of 100% eliminating such excuses.

2.
Arch. cardiol. Méx ; 88(1): 39-50, ene.-mar. 2018. tab
Article in Spanish | LILACS | ID: biblio-1054986

ABSTRACT

Resumen: El sistema cardiovascular es un sistema dinámico cuya función es asegurar un adecuado suministro de oxígeno, nutrientes y hormonas a los tejidos, necesarios para el metabolismo celular, además sintetiza y modifican los componentes vasoactivos los cuales regulan el tono vascular y la función miocárdica. Estos componentes vasoactivos son fundamentales en el manejo del paciente pediátrico en estado crítico con falla cardiaca y choque en los cuales se ha comprobado sus efectos benéficos, sin embargo, su uso y abuso trae consigo efectos nocivos, tales como mayor riesgo de arritmias, aumento el consumo miocárdico de oxígeno lo cual podría favorecer la presencia de isquemia. Por lo tanto, es preciso conocer el mecanismo de acción de los distintos tipos de agentes vasoactivos, así como las indicaciones de dichos fármacos para minimizar dichos efectos. El propósito de esta revisión es describir la farmacología y las aplicaciones clínicas de los agentes inotrópicos y Vasopresores en el paciente pediátrico en estado crítico. © 2017 Instituto Nacional de Cardiolog´ıa Ignacio Cha´vez. Publicado por Masson Doyma Me´xico S.A. Este es un art´ıculo Open Access bajo la licencia CC BY-NC-ND (https://creativecommons.org/licenses/by-nc-nd/4.0/).


Abstract: The cardiovascular system is a dynamic system, which is required to ensure adequate delivery of oxygen, nutrients, and hormones to the tissues that are necessary for cell metabolism. It also synthesises and modifies the vasoactive components that regulate vascular tone and myocardial function. These vasoactive components have demonstrated their beneficial effects in the management of paediatric patients in a critical condition with heart failure and shock. However, their use and abuse brings harmful effects, increases mortality, and is associated with arrhythmias. An increase in myocardial oxygen consumption favours the presence of ischaemia, therefore it is necessary to know the mechanism of action and indications of these drugs to minimise their harmful effects. The purpose of this review is to describe the pharmacology and clinical applications of inotropic and vasopressor agents in the paediatric patient in acritical condition. © 2017 Instituto Nacional de Cardiologìa Ignacio Chàvez. Published by Masson Doyma Mèxico S.A. This is an open access article under the CC BY-NC-ND license (http://creativecommons. org/licenses/by-nc-nd/4.0/).


Subject(s)
Humans , Child , Vasoconstrictor Agents/therapeutic use , Cardiotonic Agents/therapeutic use , Heart Failure/drug therapy
3.
Arch. cardiol. Méx ; 88(5): 376-380, dic. 2018. graf
Article in Spanish | LILACS | ID: biblio-1142145

ABSTRACT

Resumen Introducción: La prolongación del intervalo QT se asocia con arritmias ventriculares y muerte súbita. Objetivo: Determinar el valor del intervalo QTc en recién nacidos sanos y evaluar su comportamiento durante los primeros meses de vida. Métodos: Recién nacidos sanos a término de marzo-noviembre 2016 en el Hospital General de Occidente del Estado de Jalisco, México. Se les practicó un electrocardiograma de 12 derivaciones a una velocidad de 25 mm/s durante las primeras 48 h. Se midió el intervalo QT en DII y se calculó el QTc mediante la fórmula de Bazett. Los pacientes a los que se detectó prolongación del QTc en sus primeras 48 h se valoraron al mes con ECG y ecocardiograma. Si persistieron con QTc alargado se revaloraron a los 6 meses con ECG, Holter de 24 h y estudio electrocardiográfico a padres y hermanos. Los que persistieron con QTc alargado se revaloraron a los 9 meses con ECG. Resultados: Se incluyeron 548 pacientes. La media del intervalo QTc al nacimiento fue de 459 ms; durante este período 33 pacientes presentaron un QTc mayor de 470 ms, los cuales fueron evaluados al mes mediante un nuevo estudio electrocardiográfico, obteniendo una media del intervalo QTc de 446 ms. A los 6 meses se evaluaron 16 pacientes, con una media del intervalo QTc de 434 ms. A los 9 meses se evaluaron 6 pacientes, con una media del intervalo QTc de 438 ms, y solo 4 pacientes persistieron con QTc prolongado. Conclusiones: El intervalo QTc en nuestros pacientes es más prolongado en comparación con otras poblaciones y muestra una normalización paulatina.


Abstract Introduction: QT interval prolongation is associated with ventricular arrhythmias and sudden death syndrome. Objective: To determine the value of QTc interval in healthy newborns in a general hospital in Jalisco, Mexico, and their outcome during their first months of life. Methods: The study included healthy newborns from March to November 2016, in the Hospital General of Occidente in Jalisco, Mexico. A 12-lead electrocardiogram was performed at a speed of 25 mm/s during the first 48 h of life. The QT interval was measured in lead DII, and the QTc interval was calculated using the Bazett formula. Patients detected with QTc prolongation were assessed monthly with an ECG and echocardiogram. If they persisted with prolonged QTc interval, they were re-evaluated at 6 months with an ECG, 24 h Holter, and electrocardiography study on parents and siblings. Those who persisted with prolonged QTc interval were evaluated with an ECG at 9 months. Results: The study included 548 patients. The mean QTc interval at birth was 459 ms; during this period 33 patients has a QTc greated that 470 ms; which were evaluated monthly with a new electrocardiographic study, obtaining a mean QTc interal of 446 ms. At 6 months 16 patients were evaluated, with a mean QTc interval of 434 ms. At 9 months, 6 patients were found to have a mean QTc interval of 438 ms, and only 4 patients persisted with a prolonged QTc interval. Conclusions: The QTc interval in our population is prolonged compared to other populations and with a gradual return to normal.


Subject(s)
Humans , Male , Female , Infant, Newborn , Arrhythmias, Cardiac/epidemiology , Long QT Syndrome/epidemiology , Death, Sudden/epidemiology , Electrocardiography/methods , Time Factors , Long QT Syndrome/complications , Echocardiography , Pilot Projects , Electrocardiography, Ambulatory/methods , Hospitals, General/methods , Mexico/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL