Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Arq. bras. oftalmol ; 71(6,supl.0): 42-46, nov.-dez. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-507473

ABSTRACT

OBJETIVOS: Avaliar e comparar o desempenho visual, por meio da análise de frentes de onda, de seis diferentes tipos de lentes de contato gelatinosas [Cooperflex® (Coopervision), Frequency® 55 Aspheric (Coopervision), World Vision FW® (World Vision), Pure Vision® (Bausch & Lomb), Focus® Monthly (Ciba Vision), Focus® Choice AB (Ciba Vision)]. MÉTODOS: Realizou-se estudo prospectivo em amostra constituída por 130 olhos de 71 indivíduos portadores de miopia ou hipermetropia até 6,00D e astigmatismo até 1,50D, com acuidade visual corrigida com óculos igual ou superior a 20/20. Os sujeitos foram inicialmente submetidos ao exame clínico oftalmológico e posteriormente, ao exame de análise de frentes de onda com o aberrômetro LADARWave® (Alcon), em duas condições: sem correção óptica e em uso de um dos tipos de lente de contato incluídos no estudo, com grau correspondente ao equivalente esférico do paciente e corrigido pela distância vértice. Para análise de resultados os indivíduos foram divididos em seis grupos similares, sendo testado em cada grupo um dos tipos de lente incluídos no estudo. RESULTADOS: Mudanças nos valores das aberrações de alta ordem foram verificadas durante uso das lentes de contato. De 130 olhos estudados, 78 apresentaram aumento no valor de RMS total durante o uso da lente. Os seis tipos de lente estudados demonstraram tendência ao aumento no valor médio de RMS total durante seu uso, sem diferença estatisticamente significante entre as mesmas. O estudo demonstrou tendência ao aumento no valor médio das aberrações tipo "coma" durante o uso das lentes. As lentes Frequency® Aspheric e Cooperflex® apresentaram melhor desempenho visual em relação ao "coma". O estudo demonstrou tendência à diminuição no valor médio das aberrações esféricas durante o uso das lentes, sendo esta tendência maior nos pacientes míopes em relação aos hipermétropes. Foi demonstrado tendência ao aumento no valor médio de outras aberrações de alta ordem...


PURPOSE: To evaluate the visual performance by wavefront analyses of six different kinds of soft contact lenses: Cooperflex® (Cooper Vision), Frequency® 55 Aspheric (Cooper Vision), World Vision FW® (World Vision), Pure Vision® (Bausch & Lomb), Focus® Monthly (Ciba Vision) and Focus® Choice AB (Ciba Vision). METHODS: A prospective study was performed with 130 eyes of 71 myopic or hyperopic patients with astigmatism until 1.50 diopter and best corrected visual acuity 20/20 or better. The patients first underwent ophthalmic examination and then wavefront analyses without visual correction and wearing one of the different contact lenses included in the study. The patients were divided into six similar groups, each one tested with one of the six lenses included in the study. RESULTS: Changes at the values of high order aberrations were verified during the use of contact lenses. In 78 (60 percent) of the 130 analyzed eyes an increase at the RMS (rooth mean square) values during the use of contact lens was detected. All types of analyzed contact lenses showed an increase of "coma" aberrations due to contact lens use. Frequency® Aspheric and Cooperflex® had the best visual performance in relation to "coma". There was a decrease in the medium value of spherical aberrations during the use of contact lenses, higher in myopic patients than in the hyperopic. There was an increase in the other high order aberrations (that exclude the third order "coma" and fourth order spherical aberration) characterized by the component "others" on the aberrometry examination. Focus® Choice AB had the best visual performance of this component. CONCLUSION: The use of soft contact lenses modifies the performance of high order aberrations, showing an increase of the medium values of asymmetric Zernike aberrations. This was not observed for symmetric spherical aberrations. No statistically significant differences were observed between the performance of six kinds of...


Subject(s)
Adult , Humans , Contact Lenses, Hydrophilic/classification , Refraction, Ocular/physiology , Refractive Errors/physiopathology , Analysis of Variance , Corneal Topography/methods , Prospective Studies , Reference Values , Refractive Errors/rehabilitation
SELECTION OF CITATIONS
SEARCH DETAIL