Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Acta cir. bras ; 38: e384123, 2023. tab, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1519878

ABSTRACT

Purpose: To study the uptake capacity of cells from the reticuloendothelial system after irradiation with high-energy X-rays. Methods: Eighteen male Wistar rats were distributed in three groups: group A (n = 6): control, unirradiated animals studied alongside animals from group B; group B (n = 6) and group C (n = 6): animals irradiated and studied after 24 and 48 hours, respectively. The rats were anesthetized and placed on a 10 MV linear accelerator. Next, they were irradiated in the abdominal region, with 8 Gy. Twenty-four (groups A and B) and 48 hours later (group C), a colloidal carbon solution (1 mL/kg) was intravenously injected in the tail vein. Fifty minutes later, the spleens and livers were withdrawn and prepared to be studied. Kupffer cells and splenic macrophages containing carbon pigments were counted in an optical microscope. Arithmetic means were calculated for each group and compared among them. Results: X-rays were associated with a reduced number of Kupffer cells containing colloidal carbon, proliferation and enlargement of biliary ducts, hypoplasia, and hepatocyte necrosis. In the irradiated spleen, the colloidal carbon uptake was concentrated in the marginal zone around the white pulp, with an inexpressive uptake of pigments by macrophages from white and red pulps. Conclusions: The X-rays in the rat abdomen are associated with a reduction in the Kupffer cells uptake of colloidal carbon, hepatocyte disorders, bile duct proliferation, and splenic uptake of colloidal carbon concentrated in the marginal zone.


Subject(s)
Animals , Rats , Mononuclear Phagocyte System , Radiotherapy, High-Energy , Kupffer Cells
2.
Radiol. bras ; 32(4): 175-8, jul.-ago. 1999. ilus, tab
Article in Portuguese | LILACS | ID: lil-254463

ABSTRACT

Resumo: A irradiaçäo dos campos tangentes mamários inclui certa quantidade do volume pulmonar, o que pode levar a uma pneumonite radiógena. O volume de pulmäo irradiado pode ser avaliado medindo-se a altura do parênquima pulmonar irradiado (API) pelas radiografias de posicionamento ("portals"). Considera-se tecnicamente satisfeitos sempre que a API for menor ou igual a 2,5cm. Analisamos retrospectivamente "portals" de 100 pacientes, tratadas entre janeiro de 1996 e junho de 1997. Tomamos o contornodas mamas das pacientes e, por intermédio da geometria do feixe de radiaçäo, observamos o ângulo para incidência dos campos tangentes . Em 71 por cento dos casos este ângulo conduziu a uma API maior do que 2,5cm o que necessitou novo arranjo dos campos. Realizamos análise estatística objetivando encontrar uma expressäo matemática que relacionasse a API com os parâmetros geométricos do tratamento. O ajuste linear obtido, embora útil, näo foi inteiramente satisfatório, provavelmente devido a variaçöes anatômicas individuais ou a exclusäo de variáveis.


Subject(s)
Humans , Male , Female , Breast Neoplasms , Breast Neoplasms , Breast Neoplasms , Lung Volume Measurements , Radiography/adverse effects , Total Lung Capacity/radiation effects , Tidal Volume/radiation effects
3.
Radiol. bras ; 30(4): 211-215, jul.-ago. 1997. ilus, tab
Article in Portuguese | LILACS | ID: lil-309958

ABSTRACT

Utilizando a aproximação de Clarkson, desenvolvemos um método computacional para obter a dose em campos irregulares. Diferentemente de outros métodos apresentados, levamos em conta a dependência não-linear da razão espalhamento-ar (SAR) com a profundidade e tamanho de campo. Ajustando equações de um modelo teórico aos dados tabelados de SAR para campos circulares, obtêm-se os parâmetros numéricos dessas equações, com os quais o SAR é obtido para um dado tamanho de campo e profundidade. Com este método nenhuma interpolação é necessária e os erros nos valores de dose são exclusivamente de natureza experimental na determinação dos valores dos SARs. As dependências funcionais do SAR foram introduzidas em um programa de microcomputador para cálculo da dose. Comparamos valores de dose obtidos pelo método proposto com aqueles obtidos pelo cálculo manual e encontramos erros menores que 1,5 por cento em pequenas profundidades e erros da ordem de até 10 por cento para grandes profundidades. Os erros encontrados são atribuídos ao grande número de interpolações lineares que são executadas e à não-linearidade das curvas de SAR.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy
SELECTION OF CITATIONS
SEARCH DETAIL