Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Braz. j. biol ; 65(2): 217-228, May 2005. tab, mapas
Article in English | LILACS | ID: lil-417916

ABSTRACT

O objetivo deste estudo foi realizar um levantamento malacológico na bacia do reservatório de Ibirité, na região metropolitana de Belo Horizonte (Minas Gerais), e avaliar a taxa de infestação natural de Biomphalaria straminea (Gastropoda: Planorbidae)por Schistosoma mansoni (Platyhelminthes: Trematoda) e Chaetogaster limnaei (Oligochaeta: Naididae). As amostragens foram realizadas de julho a agosto de 2002. Os espécimes de B. straminea coletados foram levados para o laboratório e as avaliações da taxa de infestação foram realizadas semanalmente. O levantamento malacológico identificou cinco espécies de moluscos presentes na bacia do reservatório: B. straminea, Physa marmorata, Lymnea sp., Melanoides tuberculatus e Pomacea austrum. As observações em laboratório mostraram que os espécimes de B. straminea estavam infectados somente por C. limnaei. Apesar de não ter sido encontrado S. mansoni, a presença desse planorbídeo deve ser vista com atenção, em decorrência da possibilidade de infecção com esquistossomose humana para a população local.


Subject(s)
Animals , Biomphalaria/parasitology , Oligochaeta , Schistosoma mansoni/isolation & purification , Brazil , Disease Vectors , Fresh Water
2.
Rev. bras. eng. biomed ; 16(2): 83-87, maio-ago. 2000. tab, graf
Article in Portuguese | LILACS | ID: lil-358879

ABSTRACT

Este trabalho apresenta uma comparação dos resultados obtidos na determinação da dose absorvida na água em feixe de elétrons usando os formalismos da AAPM/TG-39 (1994) e o da IAEA/TRS-277 (1987), com o novo protocolo IAEA/TRS-381 (1997). As medidas foram realizadas no acelerador linear modelo Therac 20, que produz feixes de elétrons de 6, 9, 13, 17 e 20 MeV, instalado no Instituto Nacional de Câncer/RJ. A curva de percentual de ionização para cada energia foi obtida, utilizando uma câmara de ionização de placas paralelas, tipo NACP, em um fantoma de água, com a finalidade de especificar a qualidade dos feixes. A calibração da câmara utilizada foi feita através da comparação com uma câmara cilíndrica tipo FARMER, com fator de calibração em termos da grandeza kerma no ar, Nk, usando o feixe de 20 MeV, de acordo com o formalisma de cada um dos protocolos. Após sua calibração, a câmara de ionização de placas paralelas foi utilizada para determinar a dose absorvida na água em cada um dos feixes. A maior diferença encontrada quando comparada às respostas obtidas foi entre os protocolos IAEA/TRS-381 e AAPM/TG-39, para o feixe de 13 MeV, em torno de 1,1 por cento.


Subject(s)
Quality Control , Dosimetry , Particle Accelerators/standards , Radiation, Ionizing , Calibration , Radiation Sources , Radiation Monitoring/standards , Reference Standards
3.
Southeast Asian J Trop Med Public Health ; 1992 Mar; 23(1): 98-102
Article in English | IMSEAR | ID: sea-34593

ABSTRACT

Immunoelectrophoretic studies of common antigenicities were carried out by using rabbit sera immunized against the Belo Horizonte strain of Schistosoma mansoni eggs and crude antigens of Biomphalaria snails and vice versa. With regard to common antigenicities between S. mansoni eggs and Biomphalaria snails, S. mansoni eggs produced 4 to 5 bands with Biomphalaria glabrata pigmentado, 3 to 4 bands with B. glabrata albino and only 1 band with B. straminea. In our laboratory, the infection rate of S. mansoni miracidia to B. glabrata pigmentado was 64.3% and 55.0% for B. glabrata albino, but B. straminea was not found to be susceptible to S. mansoni miracidia. It was observe that more bands were seen between S. mansoni egg and suitable hosts. Biomphalaria snail crude antigens were fractionated by Sephadex G-100 column, and each fraction antigen was tested with anti-S. mansoni egg sera by immunoelectrophoresis. As results, three fractions were collected form each snail strains. The common antigenicities between fractionated antigens from Biomphalaria snails crude antigens and anti-S. mansoni egg sera mostly existed in the first fraction and they were estimated to have molecular weights over 45,000.


Subject(s)
Animals , Biomphalaria/immunology , Brazil , Epitopes/immunology , Evaluation Studies as Topic , Humans , Immunoelectrophoresis , Molecular Weight , Schistosoma mansoni/classification , Species Specificity
5.
Radiol. bras ; 16(1): 62-8, 1983.
Article in Portuguese | LILACS | ID: lil-17543

ABSTRACT

A qualidade e intensidade da radiacao secundaria produzida em uma unidade de telecobaltoterapia e proveniente da fonte, material que a envolve e sistema de colimacao, o que enfatiza a importancia de se medir tal influencia para cada tipo de unidade. Foi feito um estudo da distribuicao de dose na regiao de "build-up" em funcao do tamanho de campo e distancia fonte superficie (DFS) em sete unidades de telecobaltoterapia que apresentam caracteristicas distintas de construcao. Para campos pequenos, onde a contaminacao e pouco significativa, ha uma concordancia entre os resultados obtidos para as diferentes unidades. Com o aumento do tamanho de campo, o ponto de dose maxima deslocase na direcao da superficie criando "picos de contaminacao" cuja intensidade e funcao do sistema de colimacao e da distancia entre a extremidade do colimador e a superficie. O aumento da DFS acarreta uma diminuicao da dose na regiao de "build-up" justificando-se medir a distribuicao de dose para diversas distancias, uma vez que e comum utilizar-se distancias maiores a fim de se obter campos maiores. A utilizacao de mesas de tampo solido tambem altera as caracteristicas de "build-up" do feixe


Subject(s)
Cobalt , Radiation Dosage , Radiation , Radiotherapy
6.
Radiol. bras ; 16(2): 131-5, 1983.
Article in Portuguese | LILACS | ID: lil-17555

ABSTRACT

Foi feito um estudo de campos grandes aumentando-se a distancia de tratamento e verificando-se parametros tais como a razao tecido-ar, fator abertura do colimador e posicao efetiva da fonte. Os valores de TAR encontrados para as distancias de 130 cm e 180 cm foram cerca de 3% maiores que os relativos a distancia de 80 cm. Foi observado que o fator abertura do colimador independe da distancia e que o rendimento pode ser corrigido pela lei do inverso do quadrado da distancia


Subject(s)
Humans , Radiation Dosage , Radiotherapy
SELECTION OF CITATIONS
SEARCH DETAIL