Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Arch. cardiol. Méx ; 90(1): 4-11, Jan.-Mar. 2020. tab, graf
Article in English | LILACS | ID: biblio-1130999

ABSTRACT

Abstract Background: Different mechanical properties have been suggested for metallic bioresorbable vascular scaffolds (BVS) in comparison to polymeric BVS. We aim to evaluate the acute mechanical performance of Magmaris® scaffold in comparison to Absorb®. Materials and Methods: Two groups of 10 coronary lesions treated with Magmaris® and Absorb® 1.1 (20584 vs. 21016 struts) were compared. In all cases, optical coherence tomographic (OCT) images were acquired after scaffold deployment. Baseline clinical, angiographic, and procedural characteristics were compared, including OCT evaluations. Results: No baseline clinical or angiographic significant differences were found between groups. The most common indication for revascularization was effort angina (60% vs. 70% p = 0.45) with no ST-elevation myocardial infarction (MI) cases. Main target artery was left anterior descending, with a mean vessel diameter of 3.46 ± 0.23 in Absorb® and 3.52 ± 0.19mm in Magmaris® groups (p = 0.56). All cases underwent pre- and post-dilatation with a procedural success rate of 100%. OCT analyses showed larger scaffold and vessel diameters in Magmaris® group: 3.11 ± 0.38 mm versus 3.07 ± 0.36 mm, p = 0.03 and 4.12 ± 0.51 mm versus 4.04 ± 0.46 mm, p = 0.04. Despite the application of slightly higher postdilatation pressures to Magmaris® devices (18.01 ± 2.15 vs. 17.20 ± 3.80 atm, p = 0.05), significantly lower percentages of disrupted and malapposed struts were identified within Magmaris® scaffolds (0.15% vs. 0.27%, p = 0.03 and 1.06% vs. 1.46% p = 0.01). No cardiac death, target vessel-related MI, or clinically driven target lesion revascularization was reported in a 30-day follow-up. Conclusion: Mechanical properties of Magmaris® scaffold allow achieving larger vessel and scaffold diameters in a safe manner, with lower rates of malapposition and scaffold disruption.


Resumen Introducción: Se ha sugerido la presencia de un distinto comportamiento mecánico entre los dos grupos principales de dispositivos bioresorbibles: metálicos y poliméricos. En este estudio evaluamos el comportamiento mecánico agudo del andamiaje bioresorbible metálico Magmaris® frente al del polimérico Absorb®. Métodos: Se compararon dos grupos de 10 lesiones coronarias tratadas con Magmaris® y Absorb® 1.1 (20584 vs. 21016 struts). En todos los casos se realizó estudio postimplante del dispositivo mediante tomografia de coherencia óptica (OCT). Se compararon las características basales clínicas y angiográficas, así como aspectos del procedimiento (incluídos los estudios de OCT) entre ambos grupos. Resultados: No se encontraron diferencias clínicas o angiográficas estadísticamente significativas entre ambos grupos. La indicación más frecuente de revascularización coronaria fué la presencia de angina de esfuerzo (60% vs. 70% p = 0.45), sin incluirse casos de IAMCEST. La arteria descendente anterior fué el principal vaso diana, con un diámetro medio de 3.46 ± 0.23 mm en el grupo de Absorb® y de 3.52 ± 0.19mm en el grupo de Magmaris® (p = 0.56). En todos los casos se realizó pre y postdilatación, con una tasa de éxito del procedimiento del 100%. Los estudios mediante OCT demostraron un mayor diámetro de stent y del vaso en el grupo de Magmaris®: 3.11 ± 0.38mm versus 3.07 ± 0.36 mm, p = 0.03 y 4.12 ± 0.51mm versus 4.04 ± 0.46mm, p = 0.04. A pesar de someter a los dispositivos Magmaris® a presiones de postdilatación ligeramente superiores (18.01 ± 2.15 vs. 17.20 ± 3.80 atm, p = 0.05), se identificó un menor porcentaje estadísticamente significativo de struts rotos o malapuestos en dicho grupo (0.15% vs. 0.27 %, p = 0.03 y 1.06 % vs. 1.46% p = 0.01). En un seguimiento a 30 días no se registraron eventos mayores: muerte cardíaca, IM relacionado con vaso diana o TLR. Conclusión: Las propiedades mecánicas del scaffold metálico bioresorbible Magmaris® permiten alcanzar mayores diámetros de stent y vaso de forma segura tras su implante, con una baja tasa de malaposición y disrupción.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Coronary Artery Disease/surgery , Absorbable Implants , Tissue Scaffolds , Drug-Eluting Stents , Polyesters/chemistry , Prosthesis Design , Coronary Artery Disease/diagnostic imaging , Retrospective Studies , Treatment Outcome , Coronary Angiography , Tomography, Optical Coherence , Magnesium/chemistry
3.
Arch. cardiol. Méx ; 89(1): 5-11, Jan.-Mar. 2019. tab, graf
Article in English | LILACS | ID: biblio-1038470

ABSTRACT

Abstract Introduction: Carotid disease, measured as carotid intima-media thickness (CIMT) and carotid plaque (CP), is associated with major adverse cardiac and cerebrovascular events (MACCE) in people without the previous atherosclerotic disease; however, there are few published data in patients undergoing coronary angiography. The aim of the study is to determinate if the carotid disease is associated with MACCE after coronary angiography. Methods: A total of 390 consecutive patients underwent coronary angiography after exercise echocardiography and carotid ultrasonography between 2002 and 2013. MACCE was defined as stroke, myocardial infarction due to atherosclerosis progression or death due to a stroke or cardiac event. Results: Two patients were lost (0.5%). During a mean follow-up of 6.0 years (standard deviation of 2.9), 52 patients (13.4%) suffered MACCE. 1, 5, and 10 years, event-free survival was 96.4% (1.0), 88.7% (1.7), and 81.4% (2.8), respectively. Event rates at 10 years were higher in the CP group (23.2% vs. 10.2%, p = 0.013) and in the CIMT > 0.9 mm group (25.9% vs. 13.3%, p = 0.023). Multivariate analysis showed smoking habit (hazard ratio [HR] 2.51, 95% confidence interval [CI] 1.36-4.62, p = 0.003), glomerular filtration rate (HR 0.98, 95% CI 0.98-0.99), aortic stenosis (HR 2.99, 95% CI 1.24-7.21, p = 0.014), incomplete/no coronary revascularization (HR 1.97, 95% CI 1.06-3.67, p = 0.033), insulin treatment (HR 2.63, 95% CI 1.30-5.31, p = 0.006), and CP (HR 2.36, 95% CI 1.02-5.44, p = 0.044) as predictors of MACCE. Conclusions: CP is an independent predictor of MACCE in patients undergoing coronary angiography.


Resumen La enfermedad carotídea, definida como grosor de íntima media (GIMC) y placa (PC), se asocia con eventos adversos cardiacos y cerebrovasculares (EACC) en sujetos sin aterosclerosis previa; sin embargo hay pocos datos en pacientes sometidos a coronariografía. El objetivo del estudio es determinar si la enfermedad carotídea se asocia a EACC en pacientes remitidos a coronariografía Métodos: Entre 2002 y 2013 390 pacientes fueron sometidos a coronariografía tras ecocardiograma de esfuerzo y ecografía carotídea. Se definió EACC como accidente cerebrovascular, infarto de miocardio por progresión aterosclerótica o muerte por accidente cerebrovascular o causa cardiaca. Resultados: Durante un seguimiento medio de 6 años (desviación estándar 2, 9) se registraron 2 pérdidas y 52 eventos (13,4%). La supervivencia media libre de eventos a uno, cinco y diez años fue 96.4% (1.0), 88.7% (1.7) y 81.4% (2.8). Hubo mayor número de eventos a 10 años en el grupo de PC (23.2% frente 10.2%, p = 0.013) y GIMC > 0.9 mm (25,9% frente 13.3%, p = 0.023). En el análisis multivariado los predictores de EACC fueron tabaquismo (hazard ratio [HR] 2.51, intervalo de confianza [IC] al 95% 1.36-4.62, p = 0.003), filtrado glomerular renal (HR 0.98 IC95% 0.98-0.99), estenosis aórtica (HR 2.99, IC 95% 1.24-7.21, p = 0.014), revascularización incompleta/no revascularización (HR 1.97, IC 95% 1.06-3.67, p = 0.033), tratamiento con insulina (HR 2.63, IC 95% 1.30-5.31, p = 0.006) y PC (HR 2.36, 95%CI 1.02-5.44, p = 0.044). Conclusiones: La PC es un predictor independiente de EACC en pacientes sometidos a coronariografía.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Carotid Artery Diseases/complications , Coronary Angiography , Stroke/etiology , Plaque, Atherosclerotic/complications , Myocardial Infarction/etiology , Carotid Artery Diseases/diagnosis , Survival Analysis , Retrospective Studies , Risk Factors , Follow-Up Studies , Disease Progression , Stroke/diagnosis , Stroke/mortality , Myocardial Infarction/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL