Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Rev. bras. ortop ; 53(3): 350-356, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-959133

ABSTRACT

ABSTRACT Objective To evaluate patients diagnosed with posterior four-part fracture-dislocations of the proximal humerus, that were surgically treated with osteosynthesis, regarding their clinical and functional outcomes. Methods A prospective observational study of eight patients from the same hospital institution in the interior of São Paulo State (Brazil), through individual interviews using the UCLA, DASH, and Constant international scores. The active movements included in the scores plus the range of motion of the affected and non-affected limb were measured. The affected shoulder's radiographs were requested to verify bone conditions and the fixation of the osteosynthesis. Results The rating of eight patients by the international scores indicated that seven of the eight patients presented good clinical and functional evolution of the affected limb; this represents 87.5% of the evaluated individuals. Conclusion Surgical treatment with osteosynthesis performed during the acute period (<four weeks) leads to good results in most cases.


RESUMO Objetivo Avaliar os pacientes com diagnóstico de fratura-luxação posterior da extremidade proximal do úmero em quatro partes que foram tratados cirurgicamente com osteossínteses, do ponto de vista clínico e funcional. Métodos Estudo observacional prospectivo de oito pacientes de um mesmo serviço de ortopedia e traumatologia do interior do Estado de São Paulo, por meio de entrevistas individuais, com os scores internacionais de UCLA, DASH e Constant. Mediram-se os movimentos ativos incluídos nos scores e a amplitude de movimentos do membro acometido e do não acometido. Solicitaram-se radiografias do ombro acometido para verificar as condições ósseas e de fixação dos materiais de síntese. Resultados A avaliação de oito pacientes por meio dos scores usados indicou que sete apresentaram uma boa evolução clinico-funcional do membro acometido, ou seja, 87,5% dos avaliados. Conclusão O tratamento cirúrgico com osteossínteses feito no período agudo (< quatro semanas) apresenta bons resultados na maioria dos casos.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Shoulder Dislocation , Fracture Fixation, Internal , Humeral Fractures
2.
Acta ortop. bras ; 21(1): 34-39, jan.-fev. 2013. ilus
Article in Portuguese | LILACS | ID: lil-670855

ABSTRACT

Objetivo: Realizar um estudo biomecânico de quatro técnicas de fixação das fraturas em quatro partes da cabeça umeral. Métodos: A fratura foi reproduzida em 40 úmeros plásticos, divididos em grupos de dez conforme a técnica de fixação, cada uma delas empregando diferentes recursos de fixação, em configurações distintas. Os modelos umerais foram montados em uma escápula de alumínio, com tiras de couro mimetizando os tendões do capuz rotador, e submetidos a ensaios de encurvamento e de torção em uma máquina universal de ensaios, usando a rigidez relativa como parâmetro de avaliação. Montagens com o úmero intacto foram analisadas para comparação. Resultados: O comportamento biomecânico das técnicas de fixação variou dentro de uma ampla faixa, as montagens incluindo a placa DCP e os parafusos de 4,5mm de diâmetro sendo significantemente mais rígidos do que as montagens com os fios de Kirschner e os parafusos 3,5 mm de diâmetro. Conclusão: As quatro técnicas foram capazes de suportar cargas compatíveis com a demanda fisiológica, mas aquelas com a maior rigidez relativa devem ser as preferidas para finalidades clínicas. Trabalho experimental.


Objective: To carry out a biomechanical study of four techniques for fixation of four-part humeral head fractures. Methods: The fracture was reproduced in 40 plastic humeri, divided into groups of ten according to the fixation technique, each one employing different fixation resources, in different configurations. The humeral models were mounted on an aluminum scapula, with leather straps simulating the rotator cuff tendons, and submitted to bending and torsion tests in a universal testing machine, using relative stiffness as an evaluation parameter. Assemblies with intact humeri were analyzed for comparison. Results: The biomechanical behavior of the fixation techniques varied within a wide range, where the assemblies including the DCP plate and the 4.5mm diameter screws were significantly more rigid than the assemblies with the Kirschner wires and the 3.5mm diameter screws. Conclusion: The four fixation techniques were able to bear loads compatible with the physiological demand, but those with higher relative stiffness should be preferred for clinical application. Laboratory investigation.


Subject(s)
Humans , Biomechanical Phenomena/physiology , Bone Screws , Humeral Head/physiology , Fracture Fixation, Internal/methods , Scapula , Shoulder Fractures , Torsion, Mechanical
3.
Acta ortop. bras ; 14(5): 256-260, 2006. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-443615

ABSTRACT

Foi avalida a resistência à avulsão de âncoras rosqueadas de 3,5 e 4,5 mm de diâmetro, utilizando fêmores de suínos frescos congelados como modelo e uma máquina universal de ensaios. O trocânter maior era ressecado e as âncoras, montadas com um cabo de aço flexível para permitir a fixação na máquina de ensaio, eram inseridas no osso esponjoso próximo à borda da cabeça femoral, a 30°, 60° e 90° com o eixo longitudinal da diáfise femoral. Os espécimes eram fixados na máquina de ensaio e a tração era aplicada continuamente, à razão de 1 mm/minuto até que ocorresse a falha da montagem. Dados referentes à carga máxima aplicada, carga no limite da proporcionalidade, rigidez e resiliência foram registrados e comparados (p<0.05). Os resultados mostraram que a carga máxima, a carga no limite da proporcionalidade e a resiliência foram significantemente maiores (p=0,04, p=0,01 e p=0,02, respectivamente) para as âncoras de 4,5 mm de diâmetro inseridas a 60°, comparado aos outros ângulos e às âncoras de 3,5 mm em qualquer ângulo. Carga no limite da proporcionalidade e rigidez não diferiram significantemente para as âncoras de ambos os diâmetros e os diferentes ângulos de inserção.


The avulsion strength of threaded anchors with 3.5 and 4.5 mm diameter was assessed by using pigsÆ frozen fresh femurs as a model and an assay universal machine. The major trochanter was dried and the anchors, mounted with a flexible steel wire for enabling its fixation on the assay machine, were inserted into the spongy bone near femoral head edge, at 30°, 60° and 90° with femoral diaphysis longitudinal axis. The specimens were fixed on the assay machine and traction was continuously applied at a ratio of 1 mm/ minute until assembly failure occurred. Data concerning maximum load applied, load at proportionality limit, stiffness and resiliency were recorded and compared (p<0.05). The results showed that the maximum load, the load at proportionality limit, and the resiliency were significantly higher (p=0.04, p=0.01 and p=0.02, respectively) for 4.5-diameter anchors inserted at 60°, compared to other angles and to 3.5-diameter anchors at any angle. Load at proportionality limit and stiffness were not significantly different for anchors of both diameters and for different insertion angles.


Subject(s)
Animals , Male , Female , Shoulder , Materials Testing/methods , Biomechanical Phenomena , Swine , Tensile Strength , Materials Testing/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL