Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Cardiology ; (12): 804-809, 2018.
Article in Chinese | WPRIM | ID: wpr-810216

ABSTRACT

Objective@#To investigate the safety and efficacy of percutaneous intervention of children with combined congenital heart abnormality solely guided by transthoracic echocardiography (TTE) .@*Methods@#From September 2015 to June 2017, 21 children with combined congenital heart abnormality undergoing percutaneous interventional guided by TTE in Fuwai hospital were enrolled in our study, and the clinical data were retrospective analyzed. The atrial septal defect(ASD) closure, ventricular septal defect(VSD) closure, patent ductus arteriosus(PDA) closure or balloon pulmonary valvuloplasty were performed under the guidance of TTE. The procedural effect was evaluated by TTE after operation. The patients were followed up after discharged from the hospital.@*Results@#The age was (37.3±11.6) months, and there were 9 male and 12 female patients. There were 4 cases with ASD and VSD, 6 cases with VSD and PDA, 6 cases with ASD and PDA, 2 cases with VSD and pulmonary stenosis, 3 cases with ASD and pulmonary stenosis. The operations were successfully performed in all patients. No one required extra X ray guidance or open heart surgery. The operation time was (44.6±7.5)min. All patients did not require blood transfusion, inotropic support, and analgesia. There were no complications such as peripheral vascular injury and pericardialeffusion after the operation. The length of hospital stay time was (3.5±0.6) days. All patients were recovered well. The follow-up was (17.6±5.2) months, and post-procedural conduction disturbances, residual shunts, occlude fall off, thrombosis, and new onset of valvular regurgitation were not observed in these patients.@*Conclusion@#Percutaneous interventional of children with combined congenital heart abnormality solely guided by TTE is safe and effective, and the procedure can avoid the potential injuries of X ray and contrast agent.

2.
Chinese Journal of Applied Clinical Pediatrics ; (24): 990-992, 2017.
Article in Chinese | WPRIM | ID: wpr-618194

ABSTRACT

Objective To investigate the efficacy and safety of percutaneous induced thrombosis closure on small patent ductus arteriosus (PDA) solely under echocardiography guidance.Methods From June 2013 to September 2016,276 PDA patients were treated by femoral artery retrograde approach under echocardiography guidance.Twenty-five patients (14 boys,11 girls) among them with small PDA received percutaneous induced thrombosis closure because the delivery sheath could not pass PDA,with mean age (3.7 ± 1.6) years,mean body weight (16.6 ±5.4) kg and the mean diameter of the most narrow PDA was (1.3 ± 0.4) mm.All patients were assessed by transthoracic echocardiography,chest radiography and electrocardiography preoperatively.The intraoperative and postoperative effects were evaluated by echocardiography.Outpatient assessment was performed at 1,3,6 and 12 months after operation with electrocardiography and echocardiography,and yearly thereafter.Results Twenty-five patients were successfully treated with percutaneous induced thrombosis closure solely under echocardiography guidance.The mean operation time was (35.2 ± 6.1) minutes.The immediate residual shunt rates and 24 hours after operation were 28.0% (7/25 cases) and 16.0% (4/25 cases),respectively.All patients recovered and were discharged from hospital.The average hospitalization stay was (3.0 ± 0.6) days.The mean follow-up was (16.8 ± 12.3) months,residual shunt was observed in 2 patients (8.0%),and it decreased from 1.5 mm and 2.0 mm preoperatively to 0.8 mm and 1.0 mm postoperatively,respectively.All patients survived without peripheral vascular injury,cardiac perforation,PDA rupture or thrombembolia.Conclusions Percutaneous induced thrombosis closure of small PDA solely under echocardiography guidance is safe and effective.It can avoid occluder implantation and radiation injury.However,the residual shunt after operation needs following up closely.

SELECTION OF CITATIONS
SEARCH DETAIL