Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Annals of Surgical Treatment and Research ; : 72-81, 2020.
Article in English | WPRIM | ID: wpr-889248

ABSTRACT

Purpose@#This preliminary in-vitro study was designed to evaluate the risk factors of compression injury from use of a circular stapler for end-to-end anastomosis. @*Methods@#Transparent collagen plates were prepared in dry and wet conditions. Physical properties of collagen plates and porcine colon tissue were examined using a rheometer. Adjustable and fixed-type circular staplers were applied on the collagen plates and the gap distance and compressive pressure were measured during anvil approximation. Tissue injury was evaluated using a compression injury scale. Compression properties were accessed to optimal or overcompression based on gap distance. @*Results@#Unacceptable injuries were rarely observed on the dry collagens, regardless of compression device. In the adjustable compression, the compressibility ratio was similar between dry and wet collagen. Overcompression and unacceptable injury increased on the wet collagens. In the fixed compression, the compressibility ratio increased significantly and unacceptable injuries were observed in more than 50% of wet collagens. Peak pressure was significantly higher in the fixed-compression types than those of adjustable type. On bivariate correlation analysis, fixed-compression type and wet collagens were respectively associated with overcompression. On multivariate analysis, edematous collagen condition was the most important risk factor and proximal anvil side, fixed compression type, and overcompression were also independent risk factors for unacceptable compression injury. @*Conclusion@#In the edematous tissue condition, unintentional overcompression could be increased and result in tissue injury on the compression line of the circular stapler.

2.
Annals of Surgical Treatment and Research ; : 72-81, 2020.
Article in English | WPRIM | ID: wpr-896952

ABSTRACT

Purpose@#This preliminary in-vitro study was designed to evaluate the risk factors of compression injury from use of a circular stapler for end-to-end anastomosis. @*Methods@#Transparent collagen plates were prepared in dry and wet conditions. Physical properties of collagen plates and porcine colon tissue were examined using a rheometer. Adjustable and fixed-type circular staplers were applied on the collagen plates and the gap distance and compressive pressure were measured during anvil approximation. Tissue injury was evaluated using a compression injury scale. Compression properties were accessed to optimal or overcompression based on gap distance. @*Results@#Unacceptable injuries were rarely observed on the dry collagens, regardless of compression device. In the adjustable compression, the compressibility ratio was similar between dry and wet collagen. Overcompression and unacceptable injury increased on the wet collagens. In the fixed compression, the compressibility ratio increased significantly and unacceptable injuries were observed in more than 50% of wet collagens. Peak pressure was significantly higher in the fixed-compression types than those of adjustable type. On bivariate correlation analysis, fixed-compression type and wet collagens were respectively associated with overcompression. On multivariate analysis, edematous collagen condition was the most important risk factor and proximal anvil side, fixed compression type, and overcompression were also independent risk factors for unacceptable compression injury. @*Conclusion@#In the edematous tissue condition, unintentional overcompression could be increased and result in tissue injury on the compression line of the circular stapler.

3.
Tuberculosis and Respiratory Diseases ; : 120-126, 1994.
Article in Korean | WPRIM | ID: wpr-212116

ABSTRACT

BACKGROUND: Antibiotic therapy has proven an effective method of treatment on the majority of patients with pyogenic lung abscess and infected bulla. When medical therapy has failed, pulmonary resection is the current generally recommended therapy. But nowdays complications of percutaneous tube drainage has decreased with the use of small catheter. So we evaluated the effect of percutaneous tube drainage as an alternative therapy to the pyogenic lung abscess and infected bulls refractory to medical therapy in preference of the pulmonary resection. METHOD: Nine cases of the lung abscess and three cases of infected bulls which has large cavity size over 6cm, and has underlying diseases such as lung cancer, diabetes mellitus, refractory to over 1 week of antibiotics, were performed percutaneous tube drainage with All Purpose Drainage catheter(Medi-tech, Watertown, USA) under fluoroscopy. RESULTS: All the cases except one case which complicated empyema was improved clinically. Fever was down within 4days of percutaneous tube drainage(mean : 1.9days). Mean duration of tube drainage was 9.9days. CONCLUSION: Percutaneous tube drainage is an effective and relatively safe procedure in the management of lung abscesses that do not response to medical therapy We speculate this procedure should be considered as an alternative therapy for the lung abscess refractory to medical therapy in preference to the surgery. The safety and effectiveness of this procedure in infected bulla should be evaluated with an additional study.


Subject(s)
Humans , Anti-Bacterial Agents , Catheters , Diabetes Mellitus , Drainage , Empyema , Fever , Fluoroscopy , Lung Abscess , Lung Neoplasms , Lung
4.
Korean Journal of Medicine ; : 813-817, 1993.
Article in Korean | WPRIM | ID: wpr-211613

ABSTRACT

No abstract available.


Subject(s)
Liver , Osteosarcoma
5.
Korean Circulation Journal ; : 1152-1158, 1991.
Article in Korean | WPRIM | ID: wpr-28852

ABSTRACT

The sensitivity and specificity of ST segment change on ECG for detection of coronary artery disease(CAD) by pacing stress test were assessed. Among 28 cases with chest pain(mean age 52, M/F : 21/7), 10 patients had normal coronary angiographic finding(Group I), and 18 had coronary artery disease(Group II). Pacing stress test showed high specificity(100%), but low sensitivity(61%) for the diagnosis of CAD. Especially in patients with 1 vessel disease, the sensitivity was only 50%, and positive results were not attained unless there was at least 90% or more stenosis in any of the major branches(LAD, RCA or LCX). But in patients with multivessel disease, the sensitivity was much higher(83%). Lateral(V4-6) or inferior leads(2, 3, aVF) showed ischemic ST segment depression most commonly. Therefore one of the inferior lead and V5 may be a minimum requirement for monitoring pacing-induced ST segment changes. Time constant during isovolumic relaxation showed statistically significant prolongation after pacing only in CAD patient group, suggesting pacing-induced impairment of early left ventricular relaxation.


Subject(s)
Humans , Constriction, Pathologic , Coronary Artery Disease , Coronary Vessels , Depression , Diagnosis , Electrocardiography , Exercise Test , Relaxation , Sensitivity and Specificity , Thorax
SELECTION OF CITATIONS
SEARCH DETAIL