Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 889-894, 2019.
Article in Chinese | WPRIM | ID: wpr-750990

ABSTRACT

@#Objective     To introduce the application of transcatheter closure of multi-fenestrated atrial septal defect (ASD) via femoral vein under ultrasound guidance with amplatzer cribriform occluder (ACO) and atrial septal defect occluder (ASDO), as well as to assess its feasibility, effectiveness and safety. Methods     The clinical data of 48 patients with fenestrated ASD occluded via femoral vein under ultrasound guidance from December 2015 to May 2018 in our hospital were retrospectively analyzed, including 17 males and 31 females, aged 10 months to 51 years, an average of 11.50±13.86 years, and weighting 6-79 (27.00±20.14) kg. Among 48 patients with fenestrated ASD, 12 patients had double-foramen and 13 atrial septal aneurysm combined with defects and 23 multi-foramen. All patients underwent transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE) to complete the closure of fenestrated ASD. Ultrasound, electrocardiogram and chest X-ray were reviewed the next day after surgery to evaluate the curative effect. Results     Forty-eight patients with ASD were treated with 49 occluders, due to one patient with two occluders. There were 29 ASDO (8-26 mm) and 20 ACO (18-34 mm). During the operation, TTE/TEE examination showed that 48 patients were completely occluded, 13 patients showed fine bundle shunt in the unreleased push notification rod, and 9 patients had fine bundle shunt after the release of push notification rod. Fine bundle shunt was found in 8 patients 24 hours after operation, and microshunt was found in 3 patients 1 year after operation. All the patients were followed up. The occluder position was good. The right heart was reduced in different degrees, and the X-ray showed that the pulmonary blood was reduced in different degrees. No arrhythmia was found by electrocardiogram after operation. Conclusion     It is a safe and effective method to use ACO and ASDO to occlude ASD through femoral approach under ultrasound guidance.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1208-1212, 2019.
Article in Chinese | WPRIM | ID: wpr-777751

ABSTRACT

@#Objective    To evaluate the efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with transthoracic echocardiography (TTE). Methods    From February 2016 to November 2018, 98 patients of pure PDA were selected, including 43 patients of funnel type and 55 patients of tube type. There were 38 males and 60 females at age of 2-48 (9.8±10.4) years. All patients underwent TTE-guided retrograde closure of the PDA through the femoral artery to establish a femoral-abdominal aorta-thoracic aorta-ductus arteriosus-aorta-right ventricle trajectory.Under the guidance of TTE, a suitable closure umbrella was placed through the femoral artery. One month, 3 months, 6 months, 12 months after the surgery, the patients received out-patient clinical follow-up. Results    Ninety eight patients were successfully occluded by TTE. The occluder was replaced many times in an adult PDA patient, but finally it was successfully plugged. The operation time was 33.2±5.8 min. The lumbar diameter was 12±6 mm. And the postoperative murmur disappeared. Ultrasound showed no shunt between the aorta and the pulmonary artery, and the postoperative hospital stay was 3-4 days. No shunt signal was found in 1, 3, 6, 12 months follow-up. Left atrial anteroposterior diameter (25.8±6.1 mm vs. 30.6±8.4 mm) and left ventricular end diastolic diameter (38.5±9.1 mm vs. 45.2±11.5 mm) were significantly smaller (P < 0.05). Conclusion    TTE-guided transcatheter closure of PDA via femoral artery is a safe and effective method to avoid the damage of X-ray and contrast medium. The prospect of clinical application is good.

SELECTION OF CITATIONS
SEARCH DETAIL