Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Anesthesia and Pain Medicine ; : 35-40, 2020.
Article | WPRIM | ID: wpr-830305

ABSTRACT

Background@#In arthroscopic shoulder surgery, a mechanical fluid-irrigation system is used to wash out blood from the joint. If used at high pressure, it can cause side effects such as fluid extravasation, leading to airway obstruction after surgery. Desflurane is prone to increasing sympathetic nerve activity and plasma catecholamine release more than another inhalation anesthetics. The objective of this study was to determine whether desflurane could increase in the irrigation pump pressure than sevoflurane in shoulder arthroscopy. @*Methods@#Patients were randomized into a sevoflurane group (group S) and a desflurane group (group D). Each included 20 patients. For group S, sevoflurane 1.2 MAC and intravenous remifentanil were administered for anesthesia maintenance. Group D received desflurane 1.2 MAC and intravenous remifentanil. Starting at 20 mmHg of pump pressure, the surgeon estimated the visibility of the surgical field (grade I–IV). After that, the pressure was freely adjusted by the surgeon to obtain clear vision with the arthroscope during the surgery. @*Results@#The maximum pressure of the mechanical water pump was higher in group D than group S (54.0 ± 6.8 mmHg vs. 48.9 ± 5.7 mmHg, P = 0.017), but the difference was not statistically significant at a significance level of 0.01. The arthroscopic visibility at the surgical site did not differ significantly between the two groups (P = 0.284). @*Conclusions@#When desflurane is used in arthroscopic shoulder surgery, it does not require more pressure from the irrigating-fluid pump to secure a clear vision of the surgical site, compared to sevoflurane.

2.
Anesthesia and Pain Medicine ; : 73-77, 2020.
Article | WPRIM | ID: wpr-830299

ABSTRACT

Background@#Patients with hemifacial microsomia may have a difficult airway due to the accompanying mandibular deformity. Fiberoptic bronchoscope-guided intubation is commonly used method for difficult airway management. However, awake fiberoptic nasotracheal intubation has several disadvantages, including difficulty in advancement of the endotracheal tube (ETT) due to the resistance between the ETT and bronchoscope. Wire-guided fiberoptic nasotracheal intubation may help to overcome the drawbacks of the conventional method.Case: An 18-year-old man with hemifacial microsomia was scheduled for double-jaw surgery. In preoperative evaluation, he had severe retrognathia and expected difficult airway. We successfully performed wire-guided fiberoptic nasotracheal intubation combined with high-flow nasal cannula and deep sedation without any complications. @*Conclusions@#A guidewire may be useful, in case of difficultly in advancing the ETT or if a smaller tube is required, while performing intubation with FOB in patients with difficult airways.

3.
Healthcare Informatics Research ; : 247-249, 2018.
Article in English | WPRIM | ID: wpr-716030

ABSTRACT

No abstract available.


Subject(s)
Delivery of Health Care
SELECTION OF CITATIONS
SEARCH DETAIL