Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Chinese Journal of Forensic Medicine ; (6): 47-50, 2018.
Article in Chinese | WPRIM | ID: wpr-701481

ABSTRACT

Objective This exploratory study aimed to assess effectiveness with ethylene oxide treatment for removing DNA contamination. Methods 98 different spiked samples such as saliva, dander, skin cell, hair, blood and cartilage were conducted with ethylene oxide treatment. After extraction of samples, the dna was amplified and then the STR analysis was performed with 3130xl or 3500xl. Results A 6h EO treatment results showed that two saliva stains of 44 samples STR profile were detected; Just one hair of 54 samples treated with ethylene oxide was detected contaminating DNA with EO treatment for 8 hours. Conclusion This work suggested that it was more successful to reduce DNA contamination by using ethylene oxide treatment.

2.
Chinese Journal of Forensic Medicine ; (6): 614-617, 2017.
Article in Chinese | WPRIM | ID: wpr-665659

ABSTRACT

Objective This study aimed to assess the efficiency and purification of the Trace DNA extraction with a quantified method for the magnetic bead-based DNA extraction as performed on the Tecan Automated systems with TE-MAGS magnetic separator. Methods Serial dilutions of standard commercial DNA 9947A were used with the total DNA contents, 0.1ng, 0.2ng,0.3ng, 0.4ng,0.5ng, 0.6ng, 0.7ng, 0.8ng, 0.9ng,1ng,diluted progressively and a 1ng DNA (standard commercial DNA 9947A) admixed with 6 common DNA-PCR inhibitors were extracted on the Automated systems and then performed via Fluorogenic probe quantitative PCR and STR genotype for the quantification analysis of recovery and purification. Results The recovery rate of standard 9947A DNA diluted with 0.1~1ng was 38.92~60.01%, and 0.3ng and more DNA could observed the full STR profiles. For the different PCR inhibitors, above 94.5% of bile acid, collagen and urea were efficient removal during the purification process, and the hemoglobin, melanin and humic acid removal efficiency were about 97.5%, 97.85%, 82.14%, respectively.Conclusion Our results suggested that The TE-MAGS magnetic bead-based DNA extraction was suitable for the extraction of trace DNA with high recovery efficiency and purification ability.

3.
Chinese Journal of Hospital Administration ; (12): 721-724, 2017.
Article in Chinese | WPRIM | ID: wpr-662798

ABSTRACT

Objective To analyze the operation of the diagnosis-related groups ( DRGs) pilots for inpatients in the new rural cooperative medical system in Yulin city of Shaanxi province. Methods The medical records of 33306 inpatients discharged from the 3 pilot hospitals between January and July in 2017 were analyzed, aided by expert discussions, on-site assessment and medical records examinations. Results By the end of July 2017, the DRGs grouping tool had been running stably. The DRGs enrollment rates of discharged inpatients were all up to 99% in the 3 pilot hospitals. The coefficient of variation ( CV) was higher than 1 only in a few DRGs. The average length of stay and the average hospitalization expenses growth rate were both found declined. However, there also exist problems in the pilots, namely incomplete regulations for DRGs, low clinical path coverage rate, hysteretic supervision and assessment, uneven quality of medical records management and so on. Conclusions The pilots operated smoothly as evidenced in their initial success. Yet the following recommendations were raised for the improvements: To strengthen the organization and leadership to improve the DRGs related supporting system in pilot hospitals; To strengthen the promotion and application of clinical paths for standardization of the medical service process;To improve the DRGs assessment program and establish DRGs operation monitoring and tracking analysis system; To strengthen the training of medical record coding staff to improve continuously the quality of medical records.

4.
Chinese Journal of Hospital Administration ; (12): 721-724, 2017.
Article in Chinese | WPRIM | ID: wpr-660759

ABSTRACT

Objective To analyze the operation of the diagnosis-related groups ( DRGs) pilots for inpatients in the new rural cooperative medical system in Yulin city of Shaanxi province. Methods The medical records of 33306 inpatients discharged from the 3 pilot hospitals between January and July in 2017 were analyzed, aided by expert discussions, on-site assessment and medical records examinations. Results By the end of July 2017, the DRGs grouping tool had been running stably. The DRGs enrollment rates of discharged inpatients were all up to 99% in the 3 pilot hospitals. The coefficient of variation ( CV) was higher than 1 only in a few DRGs. The average length of stay and the average hospitalization expenses growth rate were both found declined. However, there also exist problems in the pilots, namely incomplete regulations for DRGs, low clinical path coverage rate, hysteretic supervision and assessment, uneven quality of medical records management and so on. Conclusions The pilots operated smoothly as evidenced in their initial success. Yet the following recommendations were raised for the improvements: To strengthen the organization and leadership to improve the DRGs related supporting system in pilot hospitals; To strengthen the promotion and application of clinical paths for standardization of the medical service process;To improve the DRGs assessment program and establish DRGs operation monitoring and tracking analysis system; To strengthen the training of medical record coding staff to improve continuously the quality of medical records.

5.
Chinese Journal of Forensic Medicine ; (6): 9-12, 2017.
Article in Chinese | WPRIM | ID: wpr-509783

ABSTRACT

Objective To evaluate the forensic application of TE-MAGS technology based on magnetic beads kit on TECAN pipetting platform and establish the automated DNA extraction system of case work samples. Methods Sensitivity test: 10 different DNA samples from 0.1ng to 1ng were prepared with a commercial standard DNA 9947A diluted into 200μL TES. DNA samples were purified by the TE-MAGS technology automatically on the TECAN pipetting platform and then typed using the IdentifilerTM Kit and get the profile of STR with the software GeneMapper ID-X; the power of purification was tested with a trail that purified 1ng DNA mixed with humus acid and hemachrome. Comparative test: 304 casework samples were divided into two purified by TE-MAGS technology and silicon beads respectively to compare the power of purification and the possibility of forensic utility. Results Sensitivity test: 0.3ng and more imported DNA can obtain a good quality of DNA profile compared to the lower imported DNA with dropout of STR peaks (0.1ng and 0.2ng). The power of purification of the TE-MAGS technology was not affected by humus acid and hemachrome. The comparison result between automatic TE-MAGS technology and manual silicon beads extraction methods from 304 casework samples showed that the former's success rate(50%) was higher than the latter(40.8%). Conclusion The established DNA purification method of TE-MAGS technology automatic DNA extraction system in this study was obviously advantaging at the aspect of success rate, stability, and uniformity and suited to application in the forensic utility future.

6.
Chinese Journal of Postgraduates of Medicine ; (36): 27-29, 2014.
Article in Chinese | WPRIM | ID: wpr-475924

ABSTRACT

Objective To discuss the efficacy of the modified falling risks for older people-community setting screening tool and the falling risks of the older people.Methods A cross-sectional study was conducted in 4 communities of Chengdu.A total of 408 people aged 65 years and over from 4 residents communities were selected with convenient sampling.To screen out the people who were in high risk of falls with a self-making questionnaire and the modified falling risks for older people-community setting screening tool.Results After the 408 older people were evaluated by modified falling risks for older people-community screening tool,the result showed the area under curve of receiver operating characteristic of the scale was 0.936.Its sensitivity was 77.6% (66/85),specificity was 93.2% (301/323),positive predictive value was 75.0% (66/88) and negative predictive value was 94.1% (301/320).Conclusions The using of modified falling risks for older people-community setting screening tool is easy and fast,it has higher sensitivity,specificity and evaluation function.It can be used for screening falling risks among community setting elderly people in China.

7.
Journal of Biomedical Engineering ; (6): 716-720, 2010.
Article in Chinese | WPRIM | ID: wpr-230798

ABSTRACT

Cardiac contractility variability (CCV) is a new concept which is introduced in the research field of cardiac contractility in recent years, that is to say, there are some disparities between cardiac contractilities when heart contracts. The changing signals of cardiac contractility contain a plenty of information on the cardiovascular function and disorder. In order to collect and analyze the message, we could quantitatively evaluate the tonicity and equilibrium of cardiac sympathetic nerve and parasympathetic nerve, and the effects of bio-molecular mechanism on the cardiovascular activities. By analyzing CCV, we could further understand the background of human being's heritage characteristics, nerve types, the adjusting mechanism, the molecular biology, and the adjustment of cardiac automatic nerve. With the development of the computing techniques, the digital signal processing method and its application in medical field, this analysis has been progressing greatly. By now, the assessment of CCV, just like the analysis of heart rate variability, is mainly via time domain and frequency domain analysis. CCV is one of the latest research fields in human cardiac signals being scarcely reported in the field of sports medicine; however, its research progresses are of important value for cardiac physiology and pathology in sports medicine and rehabilitation medicine.


Subject(s)
Humans , Autonomic Nervous System , Physiology , Exercise , Physiology , Myocardial Contraction , Physiology , Phonocardiography , Methods , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL