Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
International Journal of Traditional Chinese Medicine ; (6): 433-435, 2016.
Article in Chinese | WPRIM | ID: wpr-486480

ABSTRACT

Objective To dynamically the preparation process of Huangqi injection and to verify the rationality and existing problems of the process. Methods The preparation was made by the current standard (WS3-B-3335-98) issued by Ministry of Health, and the solid amount of the key processes were measured. The HPLC separation was performed on a Agilent Zorbax Bio-C18 reversed-phase column (250 mm × 4.6 mm, 5μm) in gradient mode of acetonitrile-water with UV detection at 254 nm. The column temperature was kept at 25 ℃, and the flow rate of mobile phase was 1.0 ml/min. Results Solid amounts of different operations of Huangqi injection were measured accurately. The content of the third water extracts was only 6.1%, and the changes of HPLC pointed the content of the 12 peaks of the second peaks decreased obviously. Conclusion The technological rationality of Huangqi injection need to be verified and optimized, the dynamic analysis of HPLC describes the changes of chemical constituents of Huangqi injection qualitatively, which also provides a reference value for establishing its fingerprint.

2.
Chinese Journal of Information on Traditional Chinese Medicine ; (12): 42-45, 2014.
Article in Chinese | WPRIM | ID: wpr-451678

ABSTRACT

Objective To study effects of oligo-peptide I-C-F-6 in carapax trionycis on rats with liver fibrosis induced by CCl4;To discuss its anti-liver fibrosis effects and possible mechanisms. Methods Forty-eight SD male rats were randomly divided into normal control group, model group, bifendate group, and oligo-peptide I-C-F-6 group, 12 in each group.CCl4 was injected intraperitoneally to build rat liver fibrosis model.Oligo-peptide I-C-F-6 group and bifendate group were given subcutaneous injection of oligo-peptide I-C-F-6 (0.12μg/g) or bifendate (0.12μg/g). At the same time, normal control group and model group were giventhe same volume of saline for seven weeks. The levels ofALT, AST,MDA, SOD, IL-4, IL-10 and TNF-α were tested.The histomorphology changes were observed under optical microscopeby HE, and the expressions of transforming growth TGF-β1 were determined by immunohistochemistry.Results Compared with model group, serum levels of ALT and AST were reduced evidently in oligo-peptide I-C-F-6 group. Hepatic content of MDA, IL-4 and TNF-α decreased, while SOD activity and IL-10 were found significantly increased. Liver fibrosis was ameliorated significantly. Hepatic expressions of TGF-β1 were weakly positive.Conclusion Oligo-peptide I-C-F-6 can ameliorate hepatocyte damage of model rats, thus it has anti-oxidative and anti-liver fibrosis effects on liver fibrosis in rats.

3.
Chinese Traditional Patent Medicine ; (12): 648-650, 2005.
Article in Chinese | WPRIM | ID: wpr-409840

ABSTRACT

AIM: To establish HPLC for the determination of icariin and adenosine in Cordyceps Vigorine Tablet. METHODS:MetaChem Polaris ODS C18-A column(4.6 mm × 250 mm, 5 μm) was adopted; acetonitrile-water was the mobile phase; detection wavelength was set at 272 nm for icariin and at 260 nm for adenosine; column linearity within the range of 0. 374-2. 246 μg for icariin and 0. 348-1. 392 μg for adenosine, respectively. The average recovery and RSD were found to be (99.4 ± 1.84) % for icariin ( n = 6), (99.63 ± 1.29 ) % for adenosine,respectively. CONCLUSION: The method is convenient, fast, reliable to operate and suitable for the quality control of Cordyceps Vigorine Tablet.

4.
Chinese Traditional and Herbal Drugs ; (24)1994.
Article in Chinese | WPRIM | ID: wpr-575498

ABSTRACT

Objective To study a fingerprint of raw material of Rhizoma Polygoni Cuspidati from(various) habitats by RP-HPLC. Methods Kromasil C_(18) column(150 mm?4.6 mm,5 ?m) was used,with mixtures of acetonitrile and water as mobile phase in a gradient mode.The flow rate was 1 mL/min and wavelength was 303 nm.Results According to the optimum chromatographic conditions,a good fingerprint of Rhizoma Polygoni Cuspidati has been described.Conclusion The method is simple and accurate with good reproducibility.It may be practical value for the quality control of sample for Rhizoma Polygoni Cuspidati from various habitats.

SELECTION OF CITATIONS
SEARCH DETAIL