Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Cancer Research and Clinic ; (6): 24-27, 2021.
Article in Chinese | WPRIM | ID: wpr-886007

ABSTRACT

Objective:To investigate the clinical value of peripheral monocyte and neutrophil count in predicting the response of patients with metastatic non-small cell lung cancer (mNSCLC) to immunosuppressive checkpoint inhibitors (ICI).Methods:The clinical data of 34 adult mNSCLC patients who received nafulizumab or pabolizumab in Danzhou People's Hospital of Hainan Province from January 2017 to March 2019 were retrospectively analyzed. The correlation of the demographic characteristics, clinical data, hematological examination results in the first two weeks before the treatment and two weeks after ICI treatment with prognosis was recorded and observed.Results:The baseline mean monocyte count [(0.52±0.09)×10 9/L vs. (0.60±0.12)×10 9/L] and neutrophil count [(4.27±0.87)×10 9/L vs.(5.39±1.02)×10 9/L] of patients with ICI reaction were lower than those of patients without ICI reaction, and the differences were statistically different ( t = -2.572, -2.727, all P < 0.05). However, there was a negative correlation between the monocyte count of the patients who responded to ICI and the reaction time ( r = -0.507, P < 0.05). The median reaction time in patients with monocyte count >0.70×10 9/L was shorter than that in patients with monocyte count ≤0.70×10 9/L (8 weeks vs. 12 weeks, χ2=4.162, P = 0.041). There was no correlation between monocyte count and time of reaction duration, progression of free survival (PFS) and overall survival (OS) ( r = -0.214, 0.182, 0.232, all P > 0.05). The decrease rate of neutrophil count in response group was higher than that in non-response group (22% vs. 2%, P < 0.05). After the first administration, cutoff value of neutrophil count was 4.2×10 9/L; the response rate of patients with neutrophil count ≤ 4.2×10 9/L was higher than that of patients with neutrophil count > 4.2×10 9/L [86.7% (13/15) vs. 36.8% (7/19), χ2=6.657, P < 0.05]. Conclusion:Peripheral blood monocyte and neutrophil count can predict the response to ICI therapy in patients with mNSCLC.

2.
Chinese Journal of Radiology ; (12): 761-765, 2018.
Article in Chinese | WPRIM | ID: wpr-707986

ABSTRACT

Objective To study the feasibility and value of magnetic resonance diffusion tensor imaging (DTI) to monitor non?arteritic anterior ischemic optic neuropathy (NAION). Methods Thirty eight NAION patients (56 eyes) were divided into acute period in 17 eyes, progressive period in 16 eyes and chronic period in 23 eyes at the base of onset time. According to matching principle, 56 eyes in 38 normal controls (NCs) were enrolled. All the patients and NCs underwent MR and DTI scan. The raw data were processed by two experienced radiologists, mean diffusivity (MD), axial diffusivities (λ//), radial diffusivities (λ┴), fractional anisotropy (FA) and Length value were got. The independent sample t test was used for the parameter values between the NAION group and the NCs group. A single factor variance analysis was used to compare the parameters among different stages of NAION group. Results Compared to the NCs group, the values of FA and Length in NAION group were reduced [0.20±0.11 vs 0.31±0.12, (5.85±0.92) vs (65.11± 6.89) mm], and the differences were statistically significant (t=-4.28,-5.25;P<0.05). The values of MD andλ┴were increased [(0.16±0.04)×10-3 vs (0.10±0.04)×10-3 mm2/s, (0.16±0.05)×10-3 vs (0.09±0.03)×10-3 mm2/s] in NAION group and the differences were statistically significant (t=6.83, 7.10;P<0.05). The value of FA and Length in acute period, progressive period and chronic period of the NAION group decreased differently compared to the NCs group. At the same time, the value of MD value and λ┴in the three periods of the NAION group increased compared to the NCs groupand the differences were statistically significant (P<0.05). The value of FA between the acute period, the progressive period, and the chronic period of NAION group were statistically signficant (F=10.88, P<0.05). However, no significant differences were found in the values of MD, λ┴and Length of the NAION group (F=0.23, 0.64, 0.33, 1.38;P=0.79, 0.54, 0.72, 0.27). Conclusion The parameters of DTI can be used to monitor the damage of optic nerve and development in NAION.

3.
Chinese Journal of Radiology ; (12): 234-238, 2012.
Article in Chinese | WPRIM | ID: wpr-425171

ABSTRACT

Objective To investigate the methods of reducing radiation dose in CT coronary angiography through optimizing individualized scan dosage protocol.Methods Two hundred patients (group A)underwent coronary CTA examination which was performed with fixed 120 kV and variable mA according to their BMI.The mA was set as 150-300 mA(BMI < 18.5 kg/m2),300-500 mA (18.5 kg/m2 ≤ BMI < 25.0 kg/m2),and 500-800 mA(BMI ≥ 25.0 kg/m2).When all examinations were finished,a linear regression was employed to analyze the correlation between mA and BMI,body surface(Suf),image noise(SD)respectively.The results of the analysis were used to formulate a regression equation,which was further used to establish a table list for quick search on how much mA that individualized coronary CTA scan would need.Another 200 patients(group B)enrolled for the individualized scan were scanned under new protocol that previous study established.The tube voltage was 100 and 120 kV.The tube current was variable according to the data in the table list.One-way ANOVA and Kruskal-wallis H test were used for statistics.Results Regression equation between mA and BMI,Suf,SD was:mA =17.984 × BMI + 169.149 × Suf-2.282 × SD-361.039.The SD(group A:32.08 ± 5.80,group B:28.60±4.47),dose index volume(CTDIvol)[group A:(41.97 ± 11.37)mGy,group B:(33.18±10.07)mGy],effective dose(ED)[group A:(10.91 ±3.07)mSy,group B:(8.83 ±2.72)mSv]had significant differences between the two groups(F =43.45,63.71,49.07 respectively,P <0.01 for all).The SD and ED results obtained in group B were better than those in group A.Conclusion Better performances were obtained when BMI combined Suf was used as a new individualized protocol than when BMI was used only,which means good image quality and lower radiation dosage in coronary CTA examination.

SELECTION OF CITATIONS
SEARCH DETAIL