Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Virology ; (6): 264-268, 2015.
Article in Chinese | WPRIM | ID: wpr-280263

ABSTRACT

To explore the spatial distribution mechanism of Japanese encephalitis virus (JEV), PhyML v3.0 was used to build phylogenetic tree using JEV sequences in the dataset. PAUP v4.0 and Migrapyhla softz ware were then used to analyze the migration events. The results showed that a total of 95 migration events were observed during the dispersal of JEV throughout Asia. Further analysis revealed that Thailand, and several Chinese provinces (including Shandong, Shanghai, Sichuan and Yunnan), were the main migration sources of JEV. JEV spread from these migration sources as follows: from Thailand to Australia, Cambodia, Tibet and India; from Shanghai to eastern coastal Asian regions and Yunnan; from Shandong to Korea, Zhejiang, Hubei, Shanxi and Liaoning; from Sichuan mainly to inland regions of China, as well as Vietnam and Japan; and from Yunnan to Zhejiang. This study indicated that frequent migration events occurred during the dispersal of JEV in the Asia and Pacific regions, and that Thailand, Shandong, Shanghai, Sichuan and Yunnan were the sources of JEV dispersal.


Subject(s)
Asia , Epidemiology , China , Epidemiology , Encephalitis Virus, Japanese , Classification , Genetics , Physiology , Encephalitis, Japanese , Epidemiology , Virology , Phylogeny
2.
Chinese Journal of Radiological Medicine and Protection ; (12): 395-397, 2011.
Article in Chinese | WPRIM | ID: wpr-424203

ABSTRACT

Objective To assess the level of radiation exposures of operators in three typical types of interventional fluoroscopic procedures.Methods Alderson Radiation Therapy (ART) phantom was used to stimulate the practices of diagnosis and therapy using TLDs for dose measurement.The radiation exposures of eye lens, neck, and breast were measured when the lead shielding of machine was on/off and the equivalent dose and effective dose to the eye lens were estimated.Results Radiation exposure of head was obviously reduced by 85% -90% when the lead shielding was on.The doses in different procedures were different.In cerebral angiography the dose equivalent of eye len was the highest in the three procedures.The annual effective dose for the operators was smaller in peripheral vascular interventions than that in cardiovascular interventional therapy and that in cerebral angiography.Conclusions The operators involved in intervention will receive an annual effective dose of less than 20 mSv as recommended by the ICRP under the protection conditions provided by the current study, except for eye lens.Attention should be paid to the protection of the eyes of operators.

SELECTION OF CITATIONS
SEARCH DETAIL