Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Article in Chinese | WPRIM | ID: wpr-1021957

ABSTRACT

BACKGROUND:In vitro lymphocyte proliferation test is often used to detect the potential immunogenicity of medical devices,but no detailed extraction conditions and dose are given in the relevant standards. OBJECTIVE:To investigate the effects of different extraction conditions of the test product and different doses of the extract on in vitro human lymphocyte proliferation,and to consider the factors that need to be considered when selecting test conditions for in vitro lymphocyte proliferation test. METHODS:In the experiment,the homogenous bone repair material and heparin-modified intraocular lens were divided into the following 12 groups:(1)Experimental group 1:24-hour complete medium(RPMI modified medium containing 10%fetal bovine serum)extract of 200 μL + lymphocyte suspension of 50 μL;(2)negative control group 1:24-hour complete medium 200 μL + lymphocyte suspension 50 μL;(3)experimental group 2:24-hour complete medium extract 100 μL + lymphocyte suspension 100 μL;(4)negative control group 2:24-hour complete medium 100 μL + lymphocyte suspension 100 μL;(5)experimental group 3:72-hour RPMI modified medium extract(addition of 10%fetal bovine serum before experiment)200 μL + lymphocyte suspension 50 μL;(6)negative control group 3:72-hour RPMI modified medium(addition of 10%fetal bovine serum before experiment)200 μL + lymphocyte suspension 50 μL;(7)experimental group 4:72-hour RPMI modified medium extract(addition of 10%fetal bovine serum before experiment)100 μL + lymphocyte suspension 100 μL;(8)negative control group 4:72-hour RPMI modified medium(addition of 10%fetal bovine serum before experiment)100 μL + lymphocyte suspension 100 μL;(9)positive control group 1:complete medium containing 10 μg/mL plant hemagglutinin-M 200 μL + lymphocyte suspension 50 μL;(10)positive control group 2:complete medium containing 10 μg/mL plant hemagglutinin-M 100 μL + lymphocyte suspension 100 μL;(11)blank control group 1:250 μL complete medium;(12)control group 2:200 μL complete medium.After 3 days of culture,the proliferation of lymphocytes was detected by CCK-8 assay. RESULTS AND CONCLUSION:(1)Under different test conditions,the extracts of the allogeneic bone repair material could enhance the activity of human lymphocytes.Under the condition of 72-hour leaching in RPMI modified medium and the volume ratio of leaching solution and lymphocyte suspension was 4:1,the most significant effect was observed.Heparin-modified intraocular lens extract also had obvious inhibitory effect on lymphocyte activity under this condition;its inhibitory effect on lymphocyte activity may be related to the heparin in the extract.However,the activity of lymphocytes was slightly enhanced by heparin-modified intraocular lens extract under the experimental conditions of complete medium extraction for 24 hours and the volume ratio of extract to lymphocyte suspension was 4:1.(2)Under different extraction conditions and doses,the results of in vitro lymphocyte proliferation test may be quite different.The selection of test conditions should be combined with the clinical application of the product,and the inherent characteristics of the product should also be considered.

2.
Article in Chinese | WPRIM | ID: wpr-939759

ABSTRACT

With the rapid development of my country's hemodialysis industry, the application of hemodialysis machines has become more and more extensive, but at the same time, the quality control technology of hemodialysis machines is not perfect. Especially for a wide range of leachable substances in dialyzers, there are few studies and detection methods. This study first briefly describes the development of hemodialyzers, and then expounds the common types of leachables, extraction methods, and chromatography and mass spectrometry conditions. It is summarized that the research plan of leachable substances is to determine the type first, then formulate the extraction plan, and then establish the detection method. Finally, we look forward to the research prospects of hemodialyzer leachables, and point out that with the deepening and extensive development of research, it can further promote the healthy development of the hemodialyzer industry.


Subject(s)
Humans , Kidney Failure, Chronic/therapy , Kidneys, Artificial , Renal Dialysis
SELECTION OF CITATIONS
SEARCH DETAIL