Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Chinese Journal of Orthopaedic Trauma ; (12): 727-732, 2019.
Article in Chinese | WPRIM | ID: wpr-754794

ABSTRACT

The elbow is more susceptible to motion loss than other joints after trauma,and elbow stiffness leads to functional impairment in the upper limb and interferes with daily activities.Open arthrolysis is the most common and classical treatment for post-traumatic elbow stiffness.In this paper,we review the treatment protocols like preoperative clinical evaluation,arthrolysis strategies and postoperative rehabilitation program for post-traumatic elbow stiffness,discuss relevant issues and assess their prospects.

2.
Chinese Journal of Orthopaedic Trauma ; (12): 317-322, 2017.
Article in Chinese | WPRIM | ID: wpr-506002

ABSTRACT

Objective To evaluate the biomechanical characteristics of 4 fixation methods (single reconstruction plate,dual reconstruction plates,single cannulated screw and dual cannulated screws) in the treatment of pubic symphysis disruption.Methods Miniature spiral CT scans were performed on the complete pelvis in 5 healthy volunteers.The primary two-dimensional CT scan data at Dicom format were imported into software Mimics 15.0 for three-dimensional reconstruction of bilateral hips and sacrums.The finite element model of skeletal pelvis was obtained by grid partitioning and assignment using software Abqus 6.13.Models of pubic symphysis disruption were simulated by cutting off the unilateral sacroiliac ligament,sacral spine ligament,sacral tuberosity ligament,pubic ligament and pubic arch.Four implants(single reconstruction plate,dual reconstruction plates,single cannulated screw and dual cannulated screws) were simulated and emplaced onto the models according to standard surgical procedures.Compressive and rotational loads were implemented in all models for finite element analysis.The biomechanical properties were recorded and analyzed,including construct stiffness,micromotion of the pubic symphysis and yon Misses stress.Results Under vertical load,the space of pubic symphysis disruption > 25 mm.The vertical stiffness and rotational construct stiffness of the pelvis decreased significantly from 442.738 ±29.946 N/mm and 10.118 ± 1.432 N · m/Deg in the normal group to 14.754 ±0.876 N/mm and 0.328 ±0.119 N · m/Deg,respectively.Dual reconstruction plates and dual cannulated screws displayed the best vertical tensile strength;their construct stiffness achieved 117.647 ±9.193 N/mm and 131.443 ±4.348 N/mm,respectively.Under anti-rotation load,dual cannulated screws displayed the best performance because they rebuilt 68.6% of the whole structural stiffness.For the local stability of the pubic symphysis,dual reconstruction plates showed a strong local anti-rotation capability and dual cannulated screws a good local anti-tensile capability.The displacement in the dual cannulated screws group was only-0.240 ±0.119 mm under vertical load while the angular displacement in the dual reconstruction plates group only 0.218°±0.182°.Single reconstruction plate endured the maximum yon Misses stress which was obviously concentrated.Conclusion Dual cannulated screws may have biomechanical advantages for treatment of pubic symphysis disruption.

3.
Chinese Journal of Orthopaedic Trauma ; (12): 126-132, 2016.
Article in Chinese | WPRIM | ID: wpr-489204

ABSTRACT

Objective To evaluate the short and mid-term effects of fixing comminuted posterior acetabular wall fractures with structural autologous iliac bone graft combined with mini screws.Methods From January 2010 to January 2014,29 patients with comminuted posterior acetabular wall fracture were treated by structural autologous iliac bone graf combined with mini screws.They were 21 males and 8 females,with a mean age of 44.2 years (range,from 22 to 58 years).The mean time form injury to operation was 7.8 days (range,from 1 to 25 days).The operations were performed through the Kocher-Langenbeck approach,with the patients in the lying position on the uninjured side.The fragments were reduced and fixed by mini screws and the ischemic ones were removed.Structural autologous iliac bone graft was used to reconstruct the posterior wall of acetabulum before a reconstruction plate was applied to compress and maintain it.The functional outcomes were evaluated by the modified Merle d'Aubigne and Postel clinical grading system at the last follow-ups.The radiographs were graded according to the Matta criteria.Results By the Matta criteria,10 cases achieved excellent reduction,16 good reduction,and 3 poor reduction,giving a good to excellent rate of 89.7%.Of this series,29 patients were followed up for 31.5 months on average (range,from 12 to 48 months).By the modified Merle d'Aubigne and Postel criteria,the functional recovery was rated as excellent in 16 cases,good in 9,fair in 3 and poor in one,giving a good to excellent rate of 86.2%.Two cases developed femoral head necrosis according to the magnetic resonance imaging 18 months postoperation.Three patients developed traumatic arthritis two years postoperation.Five patients developed heterotopic ossification postoperation,with no obvious clinical symptoms.Two patient with injury to the sciatic nerve recovered 4 months postoperation.Conclusions Structural autologous iliac graft combined with mini screws can reconstruct the integrity and stability of the fractured acetabular posterior wall,avoiding osteonecrosis of the acetabulum.This surgical technique is effective and safe in treatment of comminuted fracture of the acetabular posterior wall.

4.
Chinese Journal of Orthopaedics ; (12): 307-314, 2015.
Article in Chinese | WPRIM | ID: wpr-669888

ABSTRACT

Objective To introduce the application of computer aided technology in the treatment of pelvic malunion and observe the effect of this technique on the operation.Methods Data of 9 consecutive patients with pelvic malunion who were enrolled in our hospital from January 2009 to December 2012 were retrospectively observed.There were 4 patients who had undergone surgery with computer aided technology,including 3 men and 1 woman with an average age of 34 years (computer aided technology,CAT) group.According to the Tile classification,4 cases were all type C.There were 1 case with open pelvic fractures,2 associated with the craniocerebral injury,2 associated with the thoracic injury and 2 associated with the abdomen trauma.There were 5 patients who had undergone surgery without computer aided technology,including 3 men and 2 women with an average age of 32.6 years (conventional group).According to the Tile classification,4 cases were all type C.There were 1 case with open pelvic fractures,2 associated with the craniocerebral injury,3 associated with the thoracic injury and 1 associated with the abdomen trauma.The Majeed score,the visual analogue score (VAS),operation time,blood loss,blood transfusion,intraoperative fluoroscopy,degree of improvement in lower limb length,iatrogenic injury and the complication were all recorded respectively.Results For the CAT group,the operation time was 195-230 min,the blood loss was 800-1 6 00 ml,the blood transfusion was 6-16 U,intraoperative fluoroscopy was 6-11 times and the degree of improvement in lower limb length was 2-3 cm.The Majeed score in the final follow-up was 78-90 points,including 3 excellent cases and 1 good.The VAS after surgery was 0-4 points.For the conventional group,the operation time was 210-330 min,the blood loss was 600-4 500 ml,the blood transfusion was 6-28 U,intraoperative fluoroscopy was 7-18 times and the degree of improvement in lower limb length was 1-3 cm.The Majeed score in the final follow-up was 79-89 points,including 3 excellent cases and 2 good.The VAS after surgery was 1-4 points.Conclusion Surgeons can make full preoperative planning by the computer aided technology before the operation.This technology which reduces the operation time can make the operation more accurately,effectively and safely.

5.
International Journal of Surgery ; (12): 562-566, 2015.
Article in Chinese | WPRIM | ID: wpr-480100

ABSTRACT

Treatment of the iliosacral joint complex injury is a ehallenge for orthopedist due to the unique anatomic structure.Currently,the internal fixation has become the primary treatment method,including ilio-sacral screws,transiliac rods,anterior plates posterior compression plate,and so on.This article reviews the development process of the internal fixation methods in the treatment of the iliosacral joint complex injury.

6.
International Journal of Surgery ; (12): 733-736,封3, 2014.
Article in Chinese | WPRIM | ID: wpr-601635

ABSTRACT

Objective To explore the efficacy of double fork plate in treating the posterior wall fracture of the acetabulum.Methods Reviewed 11 patients who had treated with open reduction and internal fixation with double fork plates for posterior wall fracture of the acetabulum from July 2008 to July 2012,including 8 male cases and 3 female cases with an average age of 35.3 years(from 22 to 53 years).The average time from getting injury to operation was 7.8 days(from 1 to 19 days).The operations were performed through the Kocher-langenbeck approach.Double fork plates(formed from a three-or four-tubular plate) with an overlapping reconstruction plate used for posterior wall fragments.The functional outcomes were evaluated by the modified Merled'Aubigne and Postel'clinical garding system.The radiographs were graded according to the Matte criteria.Rmults The patients were adopted telephone or outpatient follow-up for 25 months on average(from 12 to 33 months).By the Matte criteria,7 cases achieved excellent reduction,3 good reduction,1 case fair reduction and none poor reduction,with the good and excellent rate of 90.9%.By the modified Merled'Aubigne and Postel'critria,functional recovery of the affected hip at the last followe-up was rated as excellent in 6 cases,good in 3 cases,fair in 2 cases and none poor,with the good and excellent rate of 81.8%.Heterotopic ossification was happened to 1 patient.Neither infection nor ischemic necrosis of the femoral head was recorded.Coclusion Double fork plates with an overlapping reconstruction plate can provid stable fixation and allow for early functional exercise.So the use of Double fork plates have a certain clinical value.

SELECTION OF CITATIONS
SEARCH DETAIL