1.
Journal of Tehran University Heart Center [The]. 2015; 10 (4): 167-175
in English | IMEMR | ID: emr-179325

ABSTRACT

Background: The aim of the present study was to develop a scoring system for predicting 1-year major adverse cardiac events [MACE], including mortality, target vessel or target lesion revascularization, coronary artery bypass graft surgery, and non-fatal myocardial infarction after percutaneous coronary intervention [PCI]


Methods: The data were extracted from a single center PCI registry. The score was created based on the clinical, procedural, and laboratory characteristics of 8206 patients who underwent PCI between April 2004 and October 2009. Consecutive patients undergoing PCI between November 2009 and February 2011 [n= 2875] were included as a validation data set


Results: Diabetes mellitus, increase in the creatinine level, decrease in the left ventricular ejection fraction, presentation with the acute coronary syndrome, number of diseased vessels, primary PCI, PCI on the left anterior descending artery and saphenous vein graft, and stent type and diameter were identified as the predictors of the outcome and used to develop the score [R[²] = 0.795]. The models had adequate goodness of fit [Hosmer-Lemeshow statistic; p value = 0.601] and acceptable ability of discrimination [c-statistics = 0.63]. The score categorized the individual patients as low-, moderate-, and high-risk for the occurrence of MACE. The validation of the model indicated a good agreement between the observed and expected risks


Conclusion: An individual risk-scoring system based on both clinical and procedural variables can be used conveniently to predict 1-year MACE after PCI. Risk classification based on this score can assist physicians in decision-making and postprocedural health care

2.
Journal of Tehran University Heart Center [The]. 2014; 9 (3): 115-119
in English | IMEMR | ID: emr-161466

ABSTRACT

Controversy persists over the potential benefits/harms of opium consumption in coronary heart disease. This study investigated the association between 12 months' major adverse cardiac events [MACE] and pre-procedural opium consumption among patients undergoing percutaneous coronary intervention [PCI]. Retrospectively, 1545 consecutive men who underwent PCI between 21[st] June 2009 and 20[th] June 2010 at Tehran Heart Center and were registered in the PCI Databank were entered into this cohort study. The occurrence of MACE, defined as cardiac death, non-fatal myocardial infarction, and need for target vessel revascularization [TVR] or target lesion revascularization [TLR], was compared between two groups of opium consumers and non-consumers in 350 [22.7%] patients. Sixty-four [0.86%] patients expired within 12 months. After adjustment for potential confounders, analysis revealed that opium consumption had no significant relationship with 12 months' MACE [11[3.1%] vs. 53[4.4%]; p value = 0.286, among opium users vs. non users, respectively]. Furthermore, the different components of MACE, including target vessel revascularization, target lesion revascularization, coronary artery bypass graft, and non-fatal myocardial infarction, were not significantly related to opium use. Pre-procedural opium usage in patients undergoing PCI was not associated with 12 months' MACE

3.
Journal of Tehran University Heart Center [The]. 2014; 9 (1): 46-51
in English | IMEMR | ID: emr-141941

ABSTRACT

Mitral regurgitation [MR] is a common valvular lesion in the general population with considerable impact on mortality and morbidity. The MitraClip System [Abbot Laboratories, Abbot Park, IL, USA] is a novel percutaneous approach for treating MR which involves mechanical edge-to-edge coaptation of the mitral leaflets. We present our initial experience with the MitraClip System in 5 patients. In our series, the cause of MR was both degenerative and functional. Two patients received two MitraClips due to unsatisfactory results after the implantation of the first clip. Acute procedural success was seen in 4 patients. Blood transfusion was required for 2 patients. All the patients, except one, reported improvement in functional status during a 2-month follow-up period. Our initial experience with MitraClip implantation indicates that the technique seems feasible and promising with acceptable results and that it could be offered to a broader group of patients in the near future


Subject(s)
Humans , Male , Cardiac Catheterization , Mitral Valve , Echocardiography
4.
Journal of Tehran University Heart Center [The]. 2012; 7 (3): 100-105
in English | IMEMR | ID: emr-149381

ABSTRACT

The optimal strategy in percutaneous coronary intervention [PCI] for coronary artery bifurcation lesions has yet to be agreed upon. We compared a strategy for stenting the main vessel to provide a complete perfusion flow in the side branch, namely thrombolysis in myocardial infarction [TIMI] - III, with a strategy for intervention in both the main vessel and the side branch [MV + SB]. This retrospective study utilized data on 258 consecutive patients with bifurcation lesions scheduled for PCI at Tehran Heart Center between March 2003 and March 2008. The patients were followed up for 12 months, and the primary end point was a major adverse cardiac event [MACE], i.e. cardiac death, myocardial infarction, target-vessel revascularization, and target-lesion revascularization during the 12-month follow-up period. A total of 52.7% of the patients underwent PCI on the main vessel of the bifurcation lesions [MV group] and 47.3% with a similar lesion type received a percutaneous intervention on both the main vessel and the side branch [MV + SB group]. The total rate of MACE during the follow-up was 4.3% [11 patients]; the rate was not significantly different between the MV and MV + SB groups [3.7% vs. 4.9%, respectively; p value = 0.622]. There was no association between MACE in performing a simple or complex interventional strategy to treat coronary bifurcation lesions when drawing the TIMI- III flow as a goal in a simple technique.