Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
China Journal of Chinese Materia Medica ; (24): 343-357, 2022.
Article in Chinese | WPRIM | ID: wpr-927976

ABSTRACT

A UHPLC-Q Exactive Orbitrap MS method was used to analyze the chemical constituents of the classical prescription Qianghuo Shengshi Standard Decoction(QHSS). UHPL conditions were as follows: Waters~(TM) UPLC~(TM) HSS T3 C_(18) column(2.1 mm×100 mm, 1.7 μm) and mobile phase of acetonitrile-0.1% formic acid aqueous solution. Mass spectrometry data of QHSS, each herb extract, and negative sample were collected in both positive and negative ion modes. The chemical constituents of QHSS were identified or tentatively identified based on the accurate molecular weight, retention time, MS fragmentation, comparison with reference substances, and literature reports. A total of 141 compounds were identified, including 18 amino acids, oligosaccharides, oligopeptides, and their derivatives, 19 phenolic acids, 44 coumarins, 18 flavonoids and chromones, 13 saponins, 17 phthalides, and 12 other components. This study comprehensively characterized the chemical constituents of QHSS, laying an experimental basis for the in-depth research on the material basis and quality control of QHSS.


Subject(s)
Chromatography, High Pressure Liquid , Drugs, Chinese Herbal/chemistry , Gas Chromatography-Mass Spectrometry , Mass Spectrometry , Quality Control
2.
Chinese Medical Journal ; (24): 2659-2665, 2016.
Article in English | WPRIM | ID: wpr-230904

ABSTRACT

<p><b>BACKGROUND</b>High cost of imported pacemakers is a main obstacle for Chinese patients suffering from bradyarrhythmia, and a domestically developed pacemaker will help lower the burden. This study aimed to evaluate the safety and efficacy of Qinming8631 DR (Qinming Medical, Baoji, China), the first domestically developed dual-chamber pacemaker of China, compared with a commercially available pacemaker Talos DR (Biotronik, Berlin, Germany) in Chinese patients.</p><p><b>METHODS</b>A prospective randomized trial was conducted at 14 centers in China. Participants were randomized into trial (Qinming8631 DR) and control (Talos DR) groups. Parameters of the pacing systems were collected immediately after device implantation and during follow-ups. The effective pacing rate at 6-month follow-up was recorded as the primary end point. Electrical properties, magnet response, single- and double-pole polarity conversion, rate response function, and adverse events of the pacing system were analyzed. The Cochran-Mantel-Haenszel Chi-square test, paired t-test, and Wilcoxon signed-rank test were used for measuring primary qualitative outcomes and comparing normally and abnormally distributed measurement data.</p><p><b>RESULTS</b>A total of 225 patients with a diagnosis of bradyarrhythmia and eligible for this study were randomly enrolled into the trial (n = 113) and control (n = 112) groups. They underwent successful pacemaker implantation with acceptable postoperative pacing threshold and sensitivity. Effective pacing rates of trial and control groups were comparable both in the full analysis set and the per protocol set (81.4% vs. 79.5%, P = 0.712 and 95.4% vs. 89.5%, P = 0.143, respectively). In both data sets, noninferiority of the trial group was above the predefined noninferiority limit(-9.5%).</p><p><b>CONCLUSIONS</b>This study established the noninferiority of Qinming8631 DR to Talos DR. The safety and efficacy of Qinming8631 DR pacemaker were comparable to those of Talos DR in treating patients with cardiac bradyarrhythmia.</p>


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Bradycardia , Therapeutics , Cardiac Pacing, Artificial , Methods , China , Pacemaker, Artificial , Prospective Studies
3.
Chinese Journal of Integrated Traditional and Western Medicine ; (12): 1059-1063, 2013.
Article in Chinese | WPRIM | ID: wpr-359256

ABSTRACT

<p><b>OBJECTIVE</b>To evaluate main Chinese medical syndrome elements and features of hypertriglyceridemia patients.</p><p><b>METHODS</b>Using latent structure model (LSM) method, the latent structure diagram of 826 hypertriglyceridemia patients were established. Hypertriglyceridemia syndrome elements and features were interpreted by using latent probability, conditional probability, mutual information, and cumulative information coverage to quantify symptoms/syndromes data,as well as using manual interpretation methods.</p><p><b>RESULTS</b>The accumulative information coverage rate reaching 95% was taken as the judgment standard for major syndrome elements. In the 826 hypertriglyceridemia patients, moderate and severe symptoms/syndromes (with the latent probability being 35% and 60% respectively) were dominant. The syndrome elements mainly included qi deficiency, qi stagnation,fire heat, stasis blood, yin deficiency, and yang deficiency. The main targets were dominated in Xin, Gan, and Shen.</p><p><b>CONCLUSION</b>LSM based syndrome element evaluation method could quantify the association degree of each variable (syndrome element; Chinese medical symptoms) and the occurrence probability.</p>


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Hypertriglyceridemia , Diagnosis , Medicine, Chinese Traditional , Methods , Yang Deficiency , Diagnosis , Yin Deficiency , Diagnosis
4.
Chinese Medical Journal ; (24): 44-50, 2009.
Article in English | WPRIM | ID: wpr-265876

ABSTRACT

<p><b>BACKGROUND</b>The authors found no study to compare the efficacy of bolus dose fentanyl and remifentanil blunting the cardiovascular intubation response in children, so they designed this randomized, double-blind clinical study to assess the effects of remifentanil 2 microg/kg and fentanyl 2 microg/kg by bolus injection on the cardiovascular intubation response in healthy children.</p><p><b>METHODS</b>One hundred and two children, the American Society of Anesthesiologists (ASA) physical status 1-2 and scheduled for elective plastic surgery under general anesthesia, were randomly divided into one of two groups to receive the following treatments in a double blind manner: remifentanil 2 microg/kg (Group R) and fentanyl 2 microg/kg (Group F) when anesthesia was induced with propofol and vecuronium. The orotracheal intubation was performed using a direct laryngoscope. Blood pressure (BP) and heart rate (HR) were recorded before anesthesia induction (baseline values), immediately before intubation, at intubation and every minute for 5 minutes after intubation. The percent changes of systolic blood pressure (SBP) and HR relative to baseline values and the rate pressure product (RPP) at every observing point were calculated. The incidences of SBP and HR percent changes >30% of baseline values and RPP >22,000 during the observation were recorded.</p><p><b>RESULTS</b>There were no significant differences between groups in the demographic data, baseline values of BP and HR and the intubation time. As compared to baseline values, BP, HR and RPP at intubation and their maximum values during observation increased significantly in Group F, but they all decreased significantly in Group R. BP, HR and RPP at all observed points, and their maximum values during the observation, were significantly different between groups. There were also significant differences between groups in the percent change of SBP and HR relative to baseline values at all observed points and their maximum percent changes during the observation. The incidences of SBP and HR percent increased >30% of the baseline values and RPP >22,000 during the observation, were significantly higher in Group F than in Group R, but the incidences of SBP and HR percent decreased >30% of baseline values were significantly lower in Group F compared with Group R.</p><p><b>CONCLUSIONS</b>When used as part of routine anesthesia induction with propofol and vecuronium in children, fentanyl 2 microg/kg by bolus injection fails to effectively depress the cardiovascular intubation response. Remifentanil 2 microg/kg by bolus injection can completely abolish the cardiovascular intubation response, but also cause more adverse complications of temporary significant cardiovascular depression.</p>


Subject(s)
Child , Child, Preschool , Female , Humans , Male , Anesthetics, Intravenous , Pharmacology , Therapeutic Uses , Blood Pressure , Double-Blind Method , Fentanyl , Pharmacology , Therapeutic Uses , Heart Rate , Intubation, Intratracheal , Piperidines , Pharmacology , Therapeutic Uses
5.
Chinese Medical Journal ; (24): 1290-1296, 2008.
Article in English | WPRIM | ID: wpr-294012

ABSTRACT

<p><b>BACKGROUND</b>The GlideScope videolaryngoscope (GSVL) has been shown to have no special advantage over the Macintosh direct laryngoscope (MDL) in attenuating the circulatory responses to orotracheal intubation, but no study has compared the circulatory responses to nasotracheal intubation (NTI) using the two devices. This prospective randomized clinical study was designed to determine whether there was a clinically relevant difference between the circulatory responses to NTI with the GSVL and the MDL.</p><p><b>METHODS</b>Seventy-six adult patients were randomly allocated equally to the GSVL group and the MDL group. After induction of anesthesia, NTI was performed. Non-invasive blood pressure (BP) and heart rate (HR) were recorded before induction (baseline values) and immediately before intubation (post-induction values), at intubation and every minute for a further five minutes. During the observation, times required to reach the maximum values of systolic BP (SBP) and HR, times required for recovery of SBP and HR to postinduction values and incidence of SBP and HR percent changes > 30% of baseline values were also noted. The product of HR and systolic BP, i.e. rate pressure product (RPP), and the areas under SBP and HR vs. time curves (AUC(SBP) and AUC(HR)) were calculated.</p><p><b>RESULTS</b>The NTI with the GSVL resulted in significant increases in BP, HR and RPP compared to postinduction values, but these circulatory changes did not exceed baseline values. BPs at all measuring points, AUC(SBP), maximum values of BP and incidence of SBP percent increase > 30% of baseline value during the observation did not differ significantly between groups. However, HR and RPP at intubation and their maximum values, AUC(HR) and incidence of HR percent increase > 30% of baseline value were significantly higher in the MDL group than in the GSVL group. Times required for recovery of SBP and HR to postinduction values were significantly longer in the MDL group than in the GSVL group.</p><p><b>CONCLUSIONS</b>The pressor response to NTI with the GSVL and the MDL was similar, but the tachycardiac response to NTI was lesser and of a shorter duration when using a GSVL than when using an MDL.</p>


Subject(s)
Adult , Female , Humans , Male , Blood Pressure , Heart Rate , Hemodynamics , Intubation, Intratracheal , Methods , Laryngoscopes , Prospective Studies , Reproducibility of Results , Video Recording , Methods
6.
Journal of Applied Clinical Pediatrics ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-639711

ABSTRACT

0.05).The Cormack and Lehane laryngeal exposure grades obtained by the Macintosh laryngoscope with and without ELM were significantly different(Z=3.55 P0.05).Of all 33 pediatric patients,successful orotracheal intubation using the GSLV was completed by one attempt in 31 patients and by 2 attempts in 2 cases.The time required to achieve successful tracheal intubation was 20-51(30.0? 7.9) s.Conclusions GSLV is as useful as Macintosh laryngoscope for laryngeal exposure and orotracheal intubation in children.When the orotracheal intubation is done using the GSLV in children,the distal end of a styletted endotracheal tube should be bent anteriorly to an angle of 70-80 degrees and ELM is routinely used.

SELECTION OF CITATIONS
SEARCH DETAIL