1.
Yonsei Medical Journal ; : 546-553, 2018.
Article in English | WPRIM | ID: wpr-715386

ABSTRACT

PURPOSE: The present study developed formulas for estimation of standard liver volume (SLV) with high accuracy for the Korean population. MATERIALS AND METHODS: SLV estimation formulas were established using gender-balanced and gender-unbalanced measurements of anthropometric variables, body composition variables, and abdominal geometry of healthy Koreans (n=790). Total liver volume excluding blood volume, was measured based on CT volumetry. RESULTS: SLV estimation formulas as preferred in various conditions of data availability were suggested in the present study. The suggested SLV estimation formulas in the present study were found superior to existing formulas, with an increased accuracy of 4.0–217.5 mL for absolute error and 0.2–18.7% for percentage of absolute error. CONCLUSION: SLV estimation formulas using gender-balanced measurements showed better performance than those using gender-unbalanced measurements. Inclusion of body composition and abdominal geometry variables contributed to improved performance of SLV estimation.


Subject(s)
Blood Volume , Body Composition , Liver
2.
Journal of Korean Medical Science ; : e19-2018.
Article in English | WPRIM | ID: wpr-764864

ABSTRACT

BACKGROUND: The present study investigated the diagnostic effectiveness of an LCD-based visual field testing system (LVF) in comparison with the standard automated perimetry Humphrey Field Analyzer II-750i (HFA). METHODS: A randomized controlled crossover study was conducted with 202 normal and 128 glaucomatous eyes using both LVF and HFA. The visual field testing systems were compared in terms of mean deviation (MD), pattern standard deviation (PSD), and area under the receiver operating characteristics curve (AUC) of MD and PSD differentiating the normal and glaucomatous eyes. RESULTS: Significant correlations were found between MD measurements from LVF and those from HFA for normal eyes (r = 0.342) and glaucomatous eyes (r = 0.796); slightly higher significant correlations were identified between PSD measurements from LVF and those from HFA for normal eyes (r = 0.363) and glaucomatous eyes (r = 0.828). Furthermore, high AUCs of MD were found as 0.786 for LVF and 0.868 for HFA and AUCs of PSD as 0.913 for LVF and 0.932 for HFA. CONCLUSION: The comparison results of the present study support the competence of LVF compared with HFA in visual field testing for early detection of glaucoma.


Subject(s)
Area Under Curve , Cross-Over Studies , Glaucoma , Mental Competency , ROC Curve , Visual Field Tests , Visual Fields
3.
Journal of the Korean Fracture Society ; : 180-185, 2017.
Article in Korean | WPRIM | ID: wpr-170873

ABSTRACT

PURPOSE: The purpose of this study was to verify the new hip protector design with respect to the comfort and mobility. The new hip protector was developed based on a pattern of draping and body shape of Korean elderly individuals. MATERIALS AND METHODS: An wearing characteristics evaluation was conducted on 101 elderly women wearing hip protector using a questionnaire of preference and ease of wearing. Hip protectors, with existing and newly developed belt and underwear types, which were previously preferred by the Korean elderly, were evaluated. RESULTS: The newly developed belt type (65.0%) and newly developed underwear type (30.1%) hip protectors were preferred to the existing type (3.9%) and existing underwear type (1.0%) ones. The convenience of the newly developed belt type was greater than 4 out of 5 points (1 for strongly disagree and 5 for strongly agree) for all nine measures, including fit, allowance, mobility, pad placement, pad thickness, pad size, material, design, ease of dressing, and ease of undressing. The newly developed hip protectors showed less discomfort than the existing ones. In particular, the newly developed belt type and developed underwear type improved sitting convenience by 31.1% and 26.1%, respectively, compared with the existing ones. CONCLUSION: The hip protectors developed in the present study is expected to provide better fit for the body shape of Korean elderly individuals and prevent hip fracture due to fall.


Subject(s)
Aged , Female , Humans , Bandages , Hip