Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
Add filters








Year range
1.
Chinese Journal of Ultrasonography ; (12): 627-630, 2023.
Article in Chinese | WPRIM | ID: wpr-992866

ABSTRACT

Objective:To investigate the value of ultrasound in the diagnosis of intraneural perineurioma.Methods:From June 2015 to June 2022, 11 patients with intraneural perineurioma confirmed by surgery or biopsy in Provincial Hospital Affiliated to Shandong First Medical University were retrospectively collected, all of whom underwent high-frequency ultrasound examination. Clinical data and sonographic characteristics were collected. The maximum cross-sectional area of the affected nerve was recorded and compared with the corresponding site of the contralateral nerve.Results:All the 11 cases of intraneural perineurioma were single neuropathy. The sonogram showed that the affected nerve was spindle shaped and thickened. There was a statistical difference between the maximum cross-sectional area of the thickened intraneural perineurioma and the corresponding site of the contralateral nerve [(0.158±0.043)cm vs (0.044±0.012)cm, t=8.669, P<0.001]. The fascicles of the affected nerve were thickened with loss of normal fascicular definition, but there were still hyperechoic linear separation among the fascicles. Conclusions:High-frequency ultrasound may be a valuable technique for the diagnosis of intraneural perineurioma.

2.
Chinese Journal of Ultrasonography ; (12): 885-888, 2022.
Article in Chinese | WPRIM | ID: wpr-956667

ABSTRACT

Objective:To study the clinical value of color Doppler ultrasonography in the diagnosis of persistent sciatic vein(PSV).Methods:A retrospective study was performed on 17 patients who were diagnosed with PSV by color Doppler ultrasound in the Second Hospital of Shandong University and the Shandong Provincial Hospital Affiliated to Shandong First Medical University from May 2010 to December 2021. Their sonographic features were analyzed, summarized and classified.Results:In all the 17 cases, the sciatic vein showed a vein adjacent to the sciatic nerve in the pelvis or back of the thigh. According to anatomy, persistent sciatic vein could be divided into three types: complete PSV, upper PSV and lower PSV. There were 7 cases of complete PSV, 2 cases of upper PSV and 8 cases of lower PSV. Femoral vein dysplasia was found in 11 of 17 patients with PSV. In addition to 1 case of bilateral PSV, the diameter of the femoral vein on the affected side was (0.36±0.19)cm in 16 cases, and the diameter of femoral vein at the corresponding position on the healthy side was (0.61±0.11)cm, there was significant difference between the two groups ( P<0.001). Conclusions:Color Doppler ultrasonography is the effective imaging method for diagnosis of the PSV.

3.
Chinese Journal of Applied Clinical Pediatrics ; (24): 1386-1391, 2022.
Article in Chinese | WPRIM | ID: wpr-954757

ABSTRACT

Objective:To investigate the clinical characteristics and etiology of pulmonary embolism in children, and to discuss the efficacy and safety of anticoagulation therapy.Methods:The data of 30 children with pulmonary embolism, who were treated with anticoagulation therapy in the Department of Pediatrics, Provincial Hospital Affiliated to Shandong First Medical University from January 2017 to December 2021, were analyzed retrospectively.The etiology, clinical characteristics, complications, outcomes and prognosis after anticoagulation treatment were analyzed.Results:There were 17 males and 13 females, with an average age of (8.95±2.58) years (age range: 4-13 years). The follow-up duration was 3-59 months.(1) The symptoms included cough in 30 cases (100.0%), fever in 29 cases (96.7%), shortness of breath in 27 cases (90.0%), chest pain in 15 cases (50.0%), hemoptysis in 9 cases (30.0%), bloody secretions under bronchoscopy but no hemoptysis in 4 cases (13.3%), and respiratory failure in 2 cases (6.7%). (2) The protopathy was Mycoplasma pneumoniae infection in 23 cases (76.7%), whose symptoms accorded with refractory Mycoplasma pneumoniae pneumonia.About 16 cases (53.3%) were positive for Mycoplasma pneumoniae drug resistance mutation 2063A>G or 2064A>G.Two cases (6.7%) had nephrotic syndrome.One case (3.3%) had purpura nephritis (nephrotic syndrome type). One case (3.3%) was lupus nephritis (nephrotic syndrome type). One case (3.3%) was hereditary protein S deficiency.One case (3.3%) had osteomyelitis and Staphylococcus aureus sepsis.One case (3.3%) had congenital heart disease.(3) Complications included limb thrombosis in 7 cases (23.3%), atrial thrombosis in 2 cases (6.7%), thoracic and abdominal deep venous thrombosis in 2 case (6.7%), cerebral infarction in 2 cases (6.7%), and splenic infarction in 1 case (3.3%). (4) Imaging examination showed that 30 children had lung consolidation/atelectasis (100.0%), and 24 cases had pleural effusion (80.0%). (5) Coagulation function examination suggested D-dimer increased to ≥ 5 mg/L in 21 cases (70.0%). (6) One case (3.3%) was given thrombolytic therapy with urokinase at the acute stage.Nine cases (30.0%) were treated with heparin/low molecular weight heparin.Twenty-one cases (70.0%) first received anticoagulation therapy with heparin/low molecular weight heparin and later took oral anticoagulant.Four cases (13.3%) were treated with Warfarin and 17 cases (56.7%) with Rivaroxaban.The anticoagulant treatment lasted 1-9 months.No recurrence of embolism or sequelae of chronic thromboembolic pulmonary hypertension was observed. Conclusions:Infection, especially Mycoplasma pneumoniae infection, is the main cause of pulmonary embolism in children.The symptoms of pulmonary embolism in children are atypical, so it is difficult to distinguish this disease from primary underlying diseases.Bronchoscopy can help find occult pulmonary hemorrhage.Unexplained shortness of breath in children of any age suggests the possibility of pulmonary embolism.Combination of clinical symptoms and necessary examination contribute to early diagnosis of pulmonary embolism.Then selection of appropriate anticoagulant drugs and timely anticoagulant therapy can improve the prognosis of children.

4.
Chinese Journal of Applied Clinical Pediatrics ; (24): 1386-1391, 2022.
Article in Chinese | WPRIM | ID: wpr-954740

ABSTRACT

Objective:To investigate the clinical characteristics and etiology of pulmonary embolism in children, and to discuss the efficacy and safety of anticoagulation therapy.Methods:The data of 30 children with pulmonary embolism, who were treated with anticoagulation therapy in the Department of Pediatrics, Provincial Hospital Affiliated to Shandong First Medical University from January 2017 to December 2021, were analyzed retrospectively.The etiology, clinical characteristics, complications, outcomes and prognosis after anticoagulation treatment were analyzed.Results:There were 17 males and 13 females, with an average age of (8.95±2.58) years (age range: 4-13 years). The follow-up duration was 3-59 months.(1) The symptoms included cough in 30 cases (100.0%), fever in 29 cases (96.7%), shortness of breath in 27 cases (90.0%), chest pain in 15 cases (50.0%), hemoptysis in 9 cases (30.0%), bloody secretions under bronchoscopy but no hemoptysis in 4 cases (13.3%), and respiratory failure in 2 cases (6.7%). (2) The protopathy was Mycoplasma pneumoniae infection in 23 cases (76.7%), whose symptoms accorded with refractory Mycoplasma pneumoniae pneumonia.About 16 cases (53.3%) were positive for Mycoplasma pneumoniae drug resistance mutation 2063A>G or 2064A>G.Two cases (6.7%) had nephrotic syndrome.One case (3.3%) had purpura nephritis (nephrotic syndrome type). One case (3.3%) was lupus nephritis (nephrotic syndrome type). One case (3.3%) was hereditary protein S deficiency.One case (3.3%) had osteomyelitis and Staphylococcus aureus sepsis.One case (3.3%) had congenital heart disease.(3) Complications included limb thrombosis in 7 cases (23.3%), atrial thrombosis in 2 cases (6.7%), thoracic and abdominal deep venous thrombosis in 2 case (6.7%), cerebral infarction in 2 cases (6.7%), and splenic infarction in 1 case (3.3%). (4) Imaging examination showed that 30 children had lung consolidation/atelectasis (100.0%), and 24 cases had pleural effusion (80.0%). (5) Coagulation function examination suggested D-dimer increased to ≥ 5 mg/L in 21 cases (70.0%). (6) One case (3.3%) was given thrombolytic therapy with urokinase at the acute stage.Nine cases (30.0%) were treated with heparin/low molecular weight heparin.Twenty-one cases (70.0%) first received anticoagulation therapy with heparin/low molecular weight heparin and later took oral anticoagulant.Four cases (13.3%) were treated with Warfarin and 17 cases (56.7%) with Rivaroxaban.The anticoagulant treatment lasted 1-9 months.No recurrence of embolism or sequelae of chronic thromboembolic pulmonary hypertension was observed. Conclusions:Infection, especially Mycoplasma pneumoniae infection, is the main cause of pulmonary embolism in children.The symptoms of pulmonary embolism in children are atypical, so it is difficult to distinguish this disease from primary underlying diseases.Bronchoscopy can help find occult pulmonary hemorrhage.Unexplained shortness of breath in children of any age suggests the possibility of pulmonary embolism.Combination of clinical symptoms and necessary examination contribute to early diagnosis of pulmonary embolism.Then selection of appropriate anticoagulant drugs and timely anticoagulant therapy can improve the prognosis of children.

5.
Chinese Journal of Ultrasonography ; (12): 157-160, 2022.
Article in Chinese | WPRIM | ID: wpr-932389

ABSTRACT

Objective:To investigate the diagnostic value of ultrasonography in Poland′s syndrome.Methods:From February 2016 to December 2020, the ultrasonographic images of 15 patients with Poland′s syndrome diagnosed by Provincial Hospital Affiliated to Shandong First Medical University were retrospectively analyzed, and the ultrasonographic features were summarized.Results:High-frequency ultrasound could clearly show the anatomical structures of each layer of the chest wall of the patients with Poland′s syndrome. The sonogram of Poland′s syndrome mainly showed the absence of all or part of the pectoralis major on the affected side, some of which were combined with the absence of pectoralis minor. The difference between the thickness of the affected chest wall and the healthy side was statistically significant ( P<0.01). Among the 15 cases of Poland′s syndrome, 11 cases had brachydactyly or syndactyly. Ultrasound showed that the bifurcation position of the common palmar digital artery of the middle finger was lower than that of the healthy side. Conclusions:The ultrasonography is an effective imaging method for diagnosis of Poland′s syndrome.

6.
Chinese Journal of Ultrasonography ; (12): 157-160, 2021.
Article in Chinese | WPRIM | ID: wpr-884304

ABSTRACT

Objective:To investigate the value of ultrasound in the diagnosis of hourglass-like fascicular constrictions of the anterior interosseous nerve.Methods:From July 2010 to July 2020, 12 patients with hourglass-like fascicular constrictions of the anterior interosseous nerve diagnosed in Shandong Medical Imaging Research Institute Affiliated to Shandong University were retrospectively analyzed. The characteristics of the high-frequency ultrasonographic images were summarized and compared with clinical surgery.Results:The hourglass-like fascicular constrictions of the anterior interosseous nerve were all located in the median nerve of the distal upper arm in 12 patients, including 9 cases of single hourglass change and 3 cases of multiple hourglass like changes. High-frequency ultrasound can accurately locate the location of the hourglass-like fascicular constrictions of the anterior interosseous nerve and the extent of neuropathy. The sonogram of hourglass-like fascicular constrictions of the anterior interosseous nerve showed single or multiple hourglass-like changes in the median nerve of the distal upper arm. The nerve fasciculars on both sides of hourglass-like changes were thickened. There was significant difference between the diameter of the affected fascicular and the corresponding position of the contralateral fascicular[(0.20±0.04)cm vs (0.11±0.03)cm, P<0.01]. There was significant difference between the cross-sectional area of the median nerve at the widest part of the lesion side and the corresponding position of the contralateral side[(0.14±0.03)cm 2 vs (0.09±0.03)cm 2, P<0.01]. Conclusions:High-frequency ultrasound is the preferred image method for the diagnosis of hourglass-like fascicular constrictions of the anterior interosseous nerve.

7.
Chinese Journal of Ultrasonography ; (12): 1077-1080, 2021.
Article in Chinese | WPRIM | ID: wpr-932365

ABSTRACT

Objective:To evaluate the role of high frequency ultrasonography in diagnosis of closed volar plate injury of proximal interphalangeal joint.Methods:From May 2015 to may 2021, 41 patients with acute closed volar plate injury confirmed by Department of Hand and Foot Surgery of the Provincial Hospital Affiliated to Shandong First Medical University were examined by high frequency ultrasonography. The sonographic features were analyzed and classified.Results:High frequency ultrasonography could not only clearly show the thickness, shape and echo of volar plate, but also the degree of injury and avulsion fracture of volar plate, according to which the closed volar plate injury could be divided into three types: A, B and C. Type A(13 cases): Avulsion fracture of the middle phalangeal base was found with volar plate rupture, the sonogram showed that the continuity of the volar plate attachment of the middle phalangeal base was interrupted, and avulsion fracture was found at the distal end of the volar plate. Type B(11 cases): Complete rupture of the volar plate attachment of the middle phalangeal base was found without avulsion fracture, the sonogram showed that the continuity of the volar plate attachment of the middle phalangeal base was interrupted, and the end of the volar plate contracted and thickened. Type C(17 cases): Tear of the volar plate was found, the sonogram showed enlarging volar plates, heterogeneous internal echo, and liquid dark area was visible in some cases. The average thickness of the three types of closed volar plate injury of the proximal interphalangeal joint measured by ultrasound was (0.33±0.05)cm, and the average thickness of the volar plate at the same position of the corresponding finger on the opposite side was (0.22±0.03)cm. There was significant difference between the two groups ( t=7.864, P=0.006). Conclusions:High frequency ultrasonography is the preferred imaging examination method for the diagnosis of closed volar plate injury in proximal interphalangeal joint, which has an important guiding significance for the selection of clinical treatment.

8.
Chinese Journal of Ultrasonography ; (12): 709-712, 2019.
Article in Chinese | WPRIM | ID: wpr-754864

ABSTRACT

To evaluate the value of ultrasonography in diagnosing peripheral intraneural vascular anomalies . Methods The ultrasonographic images of 10 patients with peripheral intraneural vascular anomalies confirmed by surgery or pathology were retrospectively analyzed . T he ultrasonographic features were summarized . Results T he ultrasonographic images could not only clearly show the location , involvement and blood supply of peripheral intraneural vascular anomalies , but also determined the classification of them . Ultrasonography showed enlarging nerves ,within w hich tubular structures could be observed ,and the boundary between the vascular malformations and the perineurium was not clear . Abundant arteriovenous blood flow ( arteriovenous malformation) or low velocity venous blood flow ( venous malformation) within the vascular anomalies could be detected by color Doppler examination . Conclusions Ultrasonography is the preferred imaging method for diagnosis of peripheral intraneural vascular anomalies .

9.
Chinese Journal of Ultrasonography ; (12): 991-994, 2018.
Article in Chinese | WPRIM | ID: wpr-707759

ABSTRACT

Objective To evaluate the value of color Doppler ultrasonography in diagnosing cystic adventitial disease of the popliteal artery . Methods The ultrasonographic images of 12 patients with cystic adventitial disease of the popliteal artery confirmed by surgery and pathology were retrospectivly analyzed . The ultrasonographic features were summarized . Results The ultrasonographic images showed the location ,number ,size and the compression of popliteal artery . Cystic adventitial disease of the popliteal artery showed cystic masses within popliteal artery wall . The tunica media and tunica externa were separated . Slender separations could be found in some cysts . Color Doppler ultrasonography showed no blood flow inside the cysts . When the popliteal artery was compressed ,the velocity of blood flow increased significantly . The affected popliteal artery diameter was less than that of the contralateral side [ ( 2 .858 ± 1 .256)mm vs (5 .500 ± 0 .095)mm , t =7 .531 , P <0 .01] ,the peak flow velocity of the affected popliteal artery was higher than that of the contralateral side[(213.750±119.464)cm/svs(57.417±4.209)cm/s, t =4 .465 , P <0 .01] ,the peak flow velocity of the affected posterior tibial artery was lower than that of the contralateralside[(32.417±14.569)cm/svs(47.250±4.115)cm/s,t =4.318,P <0.01] .Conclusions Color Doppler ultrasonography is the preferred imaging method for diagnosis of cystic adventitial disease of the popliteal artery .

10.
Chinese Journal of Ultrasonography ; (12): 338-341, 2018.
Article in Chinese | WPRIM | ID: wpr-707679

ABSTRACT

Objective To evaluate the value of ultrasonography in diagnosing intraneural ganglion cysts . Methods The ultrasonographic images of 12 patients with intraneural ganglion cysts confirmed by surgery and pathology were retrospectively analyzed . The ultrasonographic features were summarized . Results The ultrasonographic images showed the location ,number ,size ,shape ,boundary ,internal echo , involvement extent and blood supply in intraneural ganglion cysts clearly . Intraneural ganglion cysts showed cystic masses within peripheral nerve ,boundary clear ,irregular-shaped ,ill-acoustic transmissibility ,and separations are common ,color Doppler examination showed no blood flow inside the cysts . Conclusions High frequency sonography is the preferred imaging method for diagnosis of intraneural ganglion cysts .

11.
Chinese Journal of Ultrasonography ; (12): 330-333, 2017.
Article in Chinese | WPRIM | ID: wpr-609534

ABSTRACT

Objective To evaluate the value of ultrasonography in diagnosing tendon xanthoma.Methods The ultrasonographic images of 17 patients with tendon xanthomas confirmed by surgery and pathology were retrospectively analyzed.The ultrasonographic features were summarized.Results The ultrasonographic images showed the location,number,size,shape,boundary,internal echo,involvement and blood supply of tendon xanthomas clearly.Tendon xanthomas showed hypoechoic masses within the tendons,mostly located on the extensor aspect of the hands,feet or bilateral Achilles tendons,symmetric growth,irregular-shaped and inhomogeneous,with loss of the normal fibrillar pattern in longitudinal plane.The abundant blood flow inside the tendon can be detected by color Doppler examination.Conclusions High frequency sonography is the preferred imaging method for diagnosis of tendon xanthomas.

12.
Chinese Journal of Ultrasonography ; (12): 220-222, 2015.
Article in Chinese | WPRIM | ID: wpr-466164

ABSTRACT

Objective To study the clinical value of color Doppler ultrasonography in the persistent sciatic artery.Methods The ultrasonographic images of eleven patients with persistent sciatic artery diagnosed by CT angiography or digital subtraction angiography were retrospective analyzed,the ultrasonographic features were summarized.Results The sciatic artery showed the enlarged internal iliac artery,which continued into the thigh in a posterior location,the sciatic artery described a tortuous course toward the knee,slowly filling normal-appearing popliteal artery in 8 cases,there were no connection with popliteal artery in 1 cases.The common femoral artery and superficial femoral artery was dysplasia in 7 patients,which was thinner than the popliteal artery.Conclusions The ultrasonography is the effective imaging method for diagnosis of the persistent sciatic artery.

13.
Chinese Journal of Ultrasonography ; (12): 54-56, 2014.
Article in Chinese | WPRIM | ID: wpr-443195

ABSTRACT

Objective To study the value of high frequency sonography in diagnosis of peripheral nerve lipofibroma hamartoma.Methods The high frequency sonography images of seventeen patients with diagnosed peripheral nerve lipofibroma hamartoma were retrospective analyzed.The sonography features were compared with clinical surgery.Results The position and internal structure of nerve can be found by high frequency ultrasound,and which nerve fascicle,location and scope of lipofibroma hamartoma can be displayed clearly.The involved peripheral nerve was showed expansive growth.Because the hyperechoic fat tissue and hypoechoic nerve fibers alternated with one and another,the feature of high frequency sonography was lotus-like,there was no blood flow signal in nerve.Conclusions High frequency sonography is the preferred imaging method for diagnosis of lipofibroma hamartoma.

14.
Chinese Journal of Ultrasonography ; (12): 524-526, 2014.
Article in Chinese | WPRIM | ID: wpr-450777

ABSTRACT

Objective To study the clinical value of high frequency ultrasonography in acute closed mallet finger.Methods The high frequency ultrasonographic images of thirty-six patients with diagnosed acute closed mallet finger were retrospective analyzed.The ultrasonographic features were analyzed.Results The position and internal structure of extensor tendon could be showed by high frequency ultrasound,the position and injury level of acute closed mallet finger were identified.In 36 patients of acute closed mallet finger,6 cases were complete tear combined avulsion fracture,the ultrasonography showed the disruption in the extensor tendon at the level of the distal interphalangeal joint,the hyperechoic fracture fragment were found in the distal end of extensor tendon.22 cases were complete tear and no avulsion fracture,the longitudinal imaging showed the disruption in the extensor tendon at the level of the distal interphalangeal joint and the retraction of the tendon end.8 cases were partial tear,the ultrasonography showed that extensor tendons were thickened and hypoechoic,the section of extensor tendons were still continuous.Conclusions High frequency ultrasonography is the preferred imaging method for diagnosis of acute closed mallet finger,it will be important value for clinical treatment method.

15.
Chinese Journal of Ultrasonography ; (12): 218-221, 2014.
Article in Chinese | WPRIM | ID: wpr-446641

ABSTRACT

Objective To study the diagnosis value of giant cell temporal arteritis with high frequency ultrasonography and magnetic resonance imaging.Methods The total of 29 cases testified as giant cell temporal arteritis clinically were assessed by high frequency ultrasonography and magnetic resonance imaging.The 29 cases were assessed by high frequency ultrasonography,the 11 cases were assessed by magnetic resonance imaging,mural thickness and lumen diameter of temporal arteries were examined,and were compared with the biopsy specimens.Meanwhile 30 healthy volunteers were randomly selected as control group,the ultrasonography of normal temporal arteries were analyzed.Results All temporal arteries were diaplayed clearly.27 cases were diagnosed for giant cell temopral arteritis by high frequency ultrasonography in 29 cases,the diagnostic accuracy was 93.1%.The 11 cases were diagnosed by magnetic resonance imaging,the diagnostic accuracy was 100%.The imaging features were mural thickness,the lumen stenosis,and partial temporal arteries occluded,the mural was contrasted by Gd-DTPA.Conclusions High frequency ultrasonography and magnetic resonance imaging are noninvasive methods for giant cell temporal arteritis diagnosis,it is important clinical value for therapy.

16.
Chinese Journal of Ultrasonography ; (12): 522-524, 2013.
Article in Chinese | WPRIM | ID: wpr-434796

ABSTRACT

Objective To study the diagnosis value of high frequency sonography in nontraumatic upper limb nerve torsion.Methods High frequency sonography images of thirteen patients with diagnosed nontraumatic upper limb nerve torsion were retrospective analyzed.The sonography features were compared with the clinical surgery.Results The position and internal structure of nerve can be found by high frequency ultrasound,and which nerve fascicle,location and scope of nerve torsion can be displayed clearly.The features of high frequency sonography was single or multi-segmental hourglass-like change,the two sides of nerve with hourglass like change was thickened,the echo was low,and perineurium structures in upper limb nerve was blurry.Conclusions High frequency sonography is the preferred imaging method for diagnosis of nontraumatic upper limb nerve torsion.

17.
Chinese Journal of Ultrasonography ; (12): 511-513, 2012.
Article in Chinese | WPRIM | ID: wpr-426049

ABSTRACT

ObjectiveTostudy the value of color Doppler sonography in diagnosisof rhabdomyolysis.Methods The color Doppler sonography images of twenty-one patients with diagnosed rhabdomyolysis were retrospective analyzed.The pathological changes of the muscle were observed.Results The appearance of ultrasound was cloundness and rough-cast glass change in the diseased area of rhabdomyolysis.The diseased region can be found by ultrasound,and location and scope can be displayed clearly.There were major differences in the location of rhabdomyolysis because of etiological factor.The muscle volume and tension of rhabdomyolysis were increased for trauma,the individual patients will lead to the osteofascial compartment syndrome.There was no blood flow signal or little blood flow signal in the diseased area of rhabdomyolysis.Conclusions The color Doppler sonography is an efficient method for diagnosis of rhabdomyolysis.

18.
Chinese Journal of Radiology ; (12): 1316-1319, 2010.
Article in Chinese | WPRIM | ID: wpr-385531

ABSTRACT

Objective To explore the optimum voltage for digital chest radiography in adult. Methods PMMAs of Different thickness (7.2, 9.0, 10. 8 and 12. 6 cm) were used to simulate chest of different depth ( 17. 5, 22. 5, 27.0 and 32. 5 cm). The combinants of contrast-detail Cdrad 2.0 phantom and above PMMAs were exposed with automatic exposure control (AEC) and different tube voltages. The images of these combinants were obtained and the entrance surface dose (ESD) was recorded. The imaging quality factor (IQF) was calculated and the curves were drawn between the ESD,IQF and kV. The PMMAs of different thickness, on which a contrast object ( PMAA of 5 cm diameter and 1.8 cm thickness ) was placed, were exposed with the same condition used for above test. Their images were obtained and SNRs were calculated. Results The ESD, SNR and IQFinv of different chest depth decreased with increase of kV.When tube voltages of 70, 100 and 140 kV were used, for 17. 5 cm chest depth, the ESD was 0. 22, 0. 09 and 0. 06 mGy, the IQF was 43.3, 58. 8 and 72. 0, the SNR was 7.5, 6. 2 and 5.0; for 22. 5 cm chest depth, the ESD was 0.37, 0.12 and 0.06 mGy, the IQF was 56. 0, 61.4 and 65.3, the SNR was 6. 4, 5.2 and 3. 8; for 27. 0 cm chest depth, the ESD was 0. 52, 0. 20 and 0. 09 mGy, the IQF was 54. 2, 64. 3 and 91. 0, the SNR was 6. 0, 4. 8 and 3. 5; for 31.5 cm chest depth, the ESD was 0.53, 0.24 and 0. 10 mGy,the IQF was 53.2, 66. 8 and 95.3, the SNR was 5. 7, 4. 5 and 3. 0. Conclusion To balance ESD, SNR and IQF, proper tube voltage should be chosen for chest radiography according to thickness and constitution of patients.

19.
Acta Anatomica Sinica ; (6): 660-665, 2009.
Article in Chinese | WPRIM | ID: wpr-406086

ABSTRACT

Objective To investigate the morphology and relationships with the adjacent structures in the pineal region on the thin sections and to provide anatomic data for imaging diagnosis and surgical treatment of diseases in this region. Methods By CT and MRI examination, one normal head specimen was selected for this study. Using the computerized freezing milling technique, the specimen was sliced from anterior to posterior. The in vivo MR images were obtained from ten normal Chinese male adult volunteers using a 3.0 T GE scanner. The base lines of the sectioning and the MR scan were perpendicular to the AC-PC line. Then primary sections were contrasted with the corresponding MR images. Results By the appearance of the pineal peduncle and the disappearance of the pineal gland, the pineal region could be divided into three parts from anterior to posterior, and the shape changed from an inverted triangle to a trapezoid and a triangle gradually. The first interspace was getting wider in the anterior and middle parts of the pineal region, while in the posterior part of the pineal region, it was getting narrower and disappeared finally. From anterior to posterior, the bilateral internal cerebral veins were always in the midline of the pineal region and descended gradually.Conclusion By the computerized freezing milling technique, the anatomic details and adjacent relationships of the pineal region could be exhibited clearly in the thin serial sections, which could help the imaging diagnosis and surgical treatments for minute diseases in this region.

20.
Journal of Practical Radiology ; (12)2000.
Article in Chinese | WPRIM | ID: wpr-544574

ABSTRACT

Objective To study the effects of gantry rotation time on image quality in 64-slice spiral CT. Methods Using the same CT technique and body mode as those used for 64-slice spiral CT, delta phantom was firstly layed on the isocenter, then scanned and reconstructed with SOMATOM Sensation 64-slice spiral CT. Slice sensitivity profile(SSP) was measured from which modulation transfer function (MTF) were got by Fourier transfer. The Catphan500 phantom was layed on the table, then scanned and reconstructed with SOMATOM Sensation 64-slice spiral CT. The maximum linepair and minimum size of the targets visualized. Results The MTF curve was nearly overlapped on 0.5 s and 1.0 s gantry rotation time, the values of 5% MTF were 11.3 LP/cm and 11.9 LP/cm. Their spatial resolution and low contrast resolution were completely identical.Conclusion The image quality is no distinction on 0.5 s group and 1.0 s group of gantry rotation time. In order to shorten the scan time and eliminate the breath defect, we suggest that the 0.5 s gantry rotation time be used routinely at body spiral scan mode.

SELECTION OF CITATIONS
SEARCH DETAIL