Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Dental press j. orthod. (Impr.) ; 28(2): e2321167, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439985

ABSTRACT

ABSTRACT Objective: To evaluate the pulp chamber temperature rise (PCTR) in light-cure bonding of brackets with and without primer, in intact and restored mandibular central incisors (M1), maxillary first premolars (Mx4), and mandibular third molars (M8). Material and Methods: Ninety human teeth were included: M1 (n=30), Mx4 (n=30), and M8 (n=30). Light-cure bonding of brackets was performed in intact (n=60) and restored (n=30) teeth, with primer (n=60) or without (n=30) primer. PCTR was defined as the difference between initial (T0) and peak temperatures (T1), recorded with a thermocouple during light-cure bonding. Differences on PCTR between bonding techniques (primer vs. no primer), teeth types (M1 vs. Mx4 vs. M8), and teeth condition (intact vs. restored) were estimated by ANCOVA, with α=5%. Results: PCTR was significantly higher with the use of primer (2.05 ± 0.08oC) than without primer (1.65 ± 0.14oC) (p=0.02), and in M1 (2.23 ± 0.22oC) compared to Mx4 (1.56 ± 0.14oC) (p<0.01). There was no difference in the PCTR in M8 (1.77 ± 0.28oC) compared to M1 or Mx4 (p>0.05), and no difference between intact (1.78 ± 0.14oC) and restored (1.92 ± 0.08oC) teeth (p=0.38). There was no influence of dentin enamel thickness in the PCTR (p=0.19). Conclusion: PCTR was higher in light-cure bonding of brackets with primer, especially in M1. Light-cure bonding seems less invasive without primer.


RESUMO Objetivo: Comparar o aumento na temperatura da câmara pulpar (ATCP) na colagem de braquetes com fotoativação usando ou não primer, em dentes hígidos versus dentes restaurados, em incisivos centrais inferiores (ICI), primeiros pré-molares superiores (1PMS) e terceiros molares inferiores (3MI). Métodos: Foram incluídos noventa dentes humanos: ICI (n=30), 1PMS (n=30) e 3MI (n=30). A colagem de braquetes com fotoativação foi realizada em dentes hígidos (n=60) ou dentes restaurados (n=30), com primer (n=60) ou sem (n=30) primer. O ATCP foi definido como a diferença entre as temperaturas inicial (T0) e máxima (T1) registradas com um termômetro durante a colagem com fotoativação. As diferenças no ATCP entre as técnicas de colagem (com primer vs. sem primer), diferentes dentes (ICIvs.1PMSvs.3MI) e condição dos dentes (hígidos vs. restaurados) foram estimadas por ANCOVA, com α=5%. Resultados: O ATCP foi significativamente maior com o uso de primer (2,05 ± 0,08oC) do que sem primer (1,65 ± 0,14oC) (p=0,02), e no ICI (2,23 ± 0,22oC) do que no 1PMS (1,56 ± 0,14oC) (p<0,01). Não houve diferença no ATCP do 3MI (1,77 ± 0,28oC) em comparação com ICI ou 1PMS (p>0,05), e não houve diferença entre dentes hígidos (1,78 ± 0,14oC) e restaurados (1,92 ± 0,08oC) (p=0,38). Não houve influência da espessura da dentina e do esmalte no ATCP (p=0,19). Conclusão: O ATCP foi maior na colagem de braquetes com fotoativação usando primer, principalmente no ICI. A colagem com fotoativação parece ser menos invasiva sem primer.

2.
Dental press j. orthod. (Impr.) ; 21(6): 67-73, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-840192

ABSTRACT

ABSTRACT Introduction: There is a great variety of orthodontic brackets in the Brazilian market, and constantly evaluating them is critical for professionals to know their properties, so as to be able to choose which product best suits their clinical practice. Objectives: To evaluate the bond strength and the adhesive remnant index (ARI) of different brands of metal brackets. Material and Methods: A total of 105 bovine incisors were used, and brackets of different brands were bonded to teeth. Seven different bracket brands were tested (MorelliTM, American OrthodonticsTM, TP OrthodonticsTM, Abzil-3MTM, OrthometricTM, TecnidentTM and UNIDENTM). Twenty-four hours after bonding, shear bond strength test was performed; and after debonding, the ARI was determined by using an optical microscope at a 10-fold increase. Results: Mean shear bond strength values ranged from 3.845 ± 3.997 (MorelliTM) to 9.871 ± 5.106 MPa (TecnidentTM). The majority of the ARI index scores was 0 and 1. Conclusion: Among the evaluated brackets, the one with the lowest mean shear bond strength values was MorelliTM. General evaluation of groups indicated that a greater number of bond failure occurred at the enamel/adhesive interface.


RESUMO Introdução: atualmente, há uma grande diversidade de braquetes ortodônticos no mercado brasileiro, e a avaliação desses é fundamental para que os profissionais conheçam suas propriedades e possam qualificar a sua escolha. Objetivo: avaliar o desempenho de diferentes braquetes metálicos - com diferentes características de base -, por meio da resistência de união e do Índice de Adesivo Remanescente (IAR). Material e Métodos: braquetes de sete marcas distintas foram testados (Morelli®, American Orthodontics®, TP Orthodontics®, Abzil-3M®, Orthometric®, Tecnident® e UNIDEN®). Os braquetes foram colados em incisivos bovinos totalizando 105 corpos de prova. O teste de resistência ao cisalhamento foi realizado 24h após a colagem e, em seguida, foi avaliado o IAR, por meio do uso de um microscópio óptico, em aumento de 10 vezes. Resultados: a média dos valores de resistência de união variou entre 3,845 ± 3,997 MPa (Morelli®) e 9,871 ± 5,106 MPa (Tecnident®). A maioria dos escores do IAR foi de 0 e 1. Conclusão: entre os braquetes avaliados, o que obteve a menor média de resistência de união foi o Morelli®. A avaliação geral dos grupos indicou maior número de falhas de colagem na interface esmalte/adesivo.


Subject(s)
Humans , Dental Bonding/standards , Orthodontic Brackets/standards , Dental Bonding/methods , Dental Cements/standards , Dental Cements/therapeutic use , Shear Strength , Dental Stress Analysis
SELECTION OF CITATIONS
SEARCH DETAIL